Payment Terms | T/T, Western Union |
Supply Ability | 1000 PCS/month |
Delivery Time | 15~20 days |
Packaging Details | Plywood case |
COP | 4 |
Compressor | Panasonic or Copeland Brand |
Heat exchanger type | One plate type, one coil type |
Application | House, Appartment, School, Hospital, Villa |
Supply power | 380V/3PH/50Hz |
Refrigerant | R22/R417A/R404A/R407C/R410A |
Working ambient temperature | -15 ° C~ 45 ° C |
Warranty | 1 Year |
Installation | Freestanding |
Heating capacity range | 19~100kW |
Water outlet temp. | 55° C |
Brand Name | Shenglin |
Model Number | MDS series |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
3.2kw Swimming Pool Inverter Heat Pump , Low Temperature Heat Pump DN25
Dn25 15kw Air Source Heat Pumps For Swimming Pool Hotel Villa
Hot Water 52KW Rooftop Heat Pump High Temperature Rooftop Hvac Units
5HP 21kW Air Source Heat Pumps , Air Temp Heat Pump 5000L H
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 1000 PCS/month |
Delivery Time | 15~20 days | Packaging Details | Plywood case |
COP | 4 | Compressor | Panasonic or Copeland Brand |
Heat exchanger type | One plate type, one coil type | Application | House, Appartment, School, Hospital, Villa |
Supply power | 380V/3PH/50Hz | Refrigerant | R22/R417A/R404A/R407C/R410A |
Working ambient temperature | -15 ° C~ 45 ° C | Warranty | 1 Year |
Installation | Freestanding | Heating capacity range | 19~100kW |
Water outlet temp. | 55° C | Brand Name | Shenglin |
Model Number | MDS series | Certification | CE |
Place of Origin | China | ||
High Light | dn32 residential Water Source Heat Pumps ,dn32 db50 Water Source Heat Pumps ,dn32 MDS geothermal water pump |
R407C Refrigerant Geothermal To Water Source Heat Pump
Technical paramater:
Geothermal heat pump | MODEL | Unit | MDS50D | |
Rated heating capacity | KW | 19 | ||
Hot water supply | L/h | 400 | ||
Average heating input power | KW | 4.4 | ||
Rated heating input current | A | 9 | ||
Max outlet water temp | ℃ | 60 | ||
COP | 4.2 | |||
Power | V/Hz | 380V/50 | ||
Noise | Db(a) | 50 | ||
Dimension | W*D*H | mm | 657×557×765 | |
Packing size | W*D*H | mm | 737×637×915 | |
Unit weight | KG | 175 | ||
Working air temp range | ℃ | (-40℃)—45℃ | ||
compressor | Type | Copeland | ||
water source heat exchanger | Type | Plate heat exchange | ||
Pipe size | DN | 32 | ||
Hot water side heat exchange | Type | Coil heat exchanger | ||
Water flow | L/H | 5500L/h | ||
Water pressure down | Kpa | 40 | ||
Pipe size | DN | 25 | ||
Geothermal heat pump | MODEL | Unit | MDS60D | |
Rated heating capacity | KW | 22 | ||
Hot water supply | L/h | 520 | ||
Average heating input power | KW | 5.4 | ||
Rated heating input current | A | 12 | ||
Max outlet water temp | ℃ | 60 | ||
COP | 4.5 | |||
Power | V/Hz | 380V/50 | ||
Noise | Db(a) | 50 | ||
Dimension | W*D*H | mm | 657×557×765 | |
Packing size | W*D*H | mm | 737×637×915 | |
Unit weight | KG | 180 | ||
Working air temp range | ℃ | (-40℃)—45℃ | ||
compressor | Type | Copeland | ||
water source heat exchanger | Type | Plate heat exchange | ||
Pipe size | DN | 32 | ||
Hot water side heat exchange | Type | Coil heat exchanger | ||
Water flow | L/H | 7000L/h | ||
Water pressure down | Kpa | 45 | ||
Pipe size | DN | 25 | ||
Geothermal heat pump | MODEL | Unit | MDS100D | |
Rated heating capacity | KW | 38 | ||
Hot water supply | L/h | 800 | ||
Average heating input power | KW | 8.8 | ||
Rated heating input current | A | 18 | ||
Max outlet water temp | ℃ | 60 | ||
COP | 4.6 | |||
Power | V/Hz | 380V/50 | ||
Noise | Db(a) | 55 | ||
Dimension | W*D*H | mm | 1050*810*760 | |
Packing size | W*D*H | mm | 1140*900*910 | |
Unit weight | KG | 330 | ||
Working air temp range | ℃ | (-40℃)—45℃ | ||
compressor | Type | Copeland | ||
water source heat exchanger | Type | Plate heat exchange | ||
Pipe size | DN | 32 | ||
Hot water side heat exchange | Type | Coil heat exchanger | ||
Water flow | L/H | 11000L/h | ||
Water pressure down | Kpa | 50 | ||
Pipe size | DN | 32 | ||
Geothermal heat pump | MODEL | Unit | MDS200D | |
Rated heating capacity | KW | 76 | ||
Hot water supply | L/h | 1590 | ||
Average heating input power | KW | 17.6 | ||
Rated heating input current | A | 35 | ||
Max outlet water temp | ℃ | 60 | ||
COP | 4.6 | |||
Power | V/Hz | 380V/50 | ||
Noise | Db(a) | 58 | ||
Dimension | W*D*H | mm | 1260×850×860 | |
Packing size | W*D*H | mm | 1350×910×1020 | |
Unit weight | KG | 630 | ||
Working air temp range | ℃ | (-40℃)—45℃ | ||
compressor | Type | Copeland | ||
water source heat exchanger | Type | Plate heat exchange | ||
Pipe size | DN | 60 | ||
Hot water side heat exchange | Type | Coil heat exchanger | ||
Water flow | M3/H | 22000L/h | ||
Water pressure down | Kpa | 55 | ||
Pipe size | DN | 50 | ||
Geothermal heat pump | MODEL | Unit | MDS300D | |
Rated heating capacity | KW | 100 | ||
Hot water supply | L/h | 2400 | ||
Average heating input power | KW | 25 | ||
Rated heating input current | A | 45 | ||
Max outlet water temp | ℃ | 60 | ||
COP | 4.6 | |||
Power | V/Hz | 380V/50 | ||
Noise | Db(a) | 55 | ||
Dimension | W*D*H | mm | 1260×850×860 | |
Packing size | W*D*H | mm | 1350×910×1020 | |
Unit weight | KG | 660 | ||
Working air temp range | ℃ | (-40℃)—45℃ | ||
compressor | Type | Copeland | ||
water source heat exchanger | Type | Tube heat exchange | ||
Hot water side heat exchange | Type | Coil heat exchanger | ||
Water flow | M3/H | 30000L/h | ||
Water pressure down | Kpa | 60 | ||
Pipe size | DN | 50 |
Parts:
![]() | Heat exchanger type A: fin heat exchanger |
![]() | Heat exchanger type B: coil heat exchanger |
![]() | Heat exchanger type C: plate heat exchanger |
![]() | Electric expansion valve |
![]() | Expansion valve |
![]() | Relay |
![]() | Senssor connector |
![]() | Liquid, gas separator |
![]() | Sensor |
![]() | Thermal expansion valve |
![]() | Control panel |
Installation diagram:
Water source heat pump makes use of understand water, river water,tap water, industrial waste water as water source. People can select the suitable water source according to the most favorable conditions. If take use of under ground water, we dig wells, and usually return wells are more than pumps wells, because pumping water is easier than returning water.
For ground source hwat pump, the ground source is based o nan underground buried pipe system. The two ends of the buried are connected to the inlet/outlet of source side heat exchangers of the heat pump. And the liquid circulates inside the pipe, so that transfer the heat from soil to water for life continuelly.
Simple installation diagram for water and geothermal source:
Company Details
Business Type:
Manufacturer
Year Established:
2009
Employee Number:
>100
Ecer Certification:
Active Member
Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ... Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ...
Get in touch with us