Payment Terms | T/T, Western Union |
Supply Ability | 100 Units Per Month |
Delivery Time | 35~40days |
Packaging Details | Plywood wooden box or pallet |
Type | Chilled water type |
Air cooled or water cooled | Air cooled |
Heater type | Steam or water coil |
Structure type | Cabinet/ ceiling / vertical / horizontal type |
Fan type | Direct drive motor or belt-driven |
Application | hotels, theaters, shopping malls, office buildings |
Air volume | 2000~50000m³/h |
Optional installation accessories | Air valve, air duct or air grill |
Brand Name | Shenglin |
Model Number | SL-ZKW Series |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
Purification Clean Room Chilled Water Air Handling Units
Air Cooled DX Air Handling Units G4 Filters Commercial Air Handler
50000m3/H Clean Room Air Handling Units rooftop packaged
Constant Temperature Humidity Chilled Water AHU For Hospital Operating Room
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 100 Units Per Month |
Delivery Time | 35~40days | Packaging Details | Plywood wooden box or pallet |
Type | Chilled water type | Air cooled or water cooled | Air cooled |
Heater type | Steam or water coil | Structure type | Cabinet/ ceiling / vertical / horizontal type |
Fan type | Direct drive motor or belt-driven | Application | hotels, theaters, shopping malls, office buildings |
Air volume | 2000~50000m³/h | Optional installation accessories | Air valve, air duct or air grill |
Brand Name | Shenglin | Model Number | SL-ZKW Series |
Certification | CE | Place of Origin | China |
High Light | 2000m3 h water air handlers ,300pa ceiling water air handlers ,2000m3 h ahu air conditioning |
Chilled Water Air Handing Unit Spec. Table No. 1 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Model SL-ZKW- | 20 | 40 | 60 | 80 | 100 | 150 | 200 | 250 | 300 | ||
Air volume(m³/h) | 2000 | 4000 | 6000 | 8000 | 10000 | 15000 | 20000 | 25000 | 30000 | ||
Outlet air pressure(pa) | 300 | 300 | 400 | 500 | 500 | 600 | 750 | 750 | 750 | ||
Supply fan capacity(kw) | 1.1 | 1.5 | 2.2 | 4 | 5.5 | 11 | 15 | 15 | 18.5 | ||
Cooling | 4 Rows | Return air(kw) | 12.2 | 23.9 | 35.9 | 48 | 60 | 90 | 120 | 150 | 179 |
water flow(m³/h) | 2.2 | 4.2 | 6.1 | 8.2 | 10.5 | 15.3 | 20.4 | 23.8 | 28.2 | ||
all fresh air(kw) | 22 | 43.8 | 62 | 90 | 112 | 156 | 210 | 265 | 310 | ||
water flow(m³/h) | 3.8 | 7.7 | 11 | 15.5 | 19.2 | 27.3 | 36.5 | 45.8 | 55 | ||
pipe diameter (DN) | 25 | 32 | 40 | 40 | 40 | 50 | 65 | 65 | 80 | ||
6 Rows | Return air(kw) | 17 | 30.1 | 45.2 | 60 | 75 | 113 | 151 | 188 | 210 | |
water flow(m³/h) | 2.8 | 5.3 | 7.7 | 10.5 | 13.6 | 19.2 | 25.5 | 30.2 | 36 | ||
all fresh air(kw) | 30.5 | 58 | 88 | 118 | 150 | 200 | 288 | 355 | 420 | ||
water flow(m³/h) | 5.1 | 10 | 15.2 | 20.2 | 26.2 | 35.5 | 49 | 70 | 72.5 | ||
pipe diameter (DN) | 32 | 32 | 40 | 40 | 50 | 65 | 65 | 80 | 80 | ||
8 Rows | Return air(kw) | 18.3 | 35.2 | 53 | 70 | 90 | 132 | 176 | 220 | 264 | |
water flow(m³/h) | 3.2 | 6.2 | 8.9 | 12.2 | 16.2 | 22.2 | 30.2 | 37.2 | 44.2 | ||
all fresh air(kw) | 34.8 | 70 | 101 | 138 | 178 | 245 | 332 | 410 | 500 | ||
water flow(m³/h) | 5.8 | 12 | 17.5 | 23.5 | 30.8 | 42.5 | 57.1 | 71 | 85 | ||
pipe diameter (DN) | 32 | 32 | 40 | 40 | 50 | 65 | 65 | 80 | 80 | ||
Heating | 2 Rows | Return air(kw) | 20 | 42 | 60 | 84 | 108 | 150 | 200 | 250 | 300 |
water flow(m³/h) | 0.8 | 1.9 | 2.6 | 3.7 | 4.6 | 6.5 | 8.7 | 11 | 13 | ||
all fresh air(kw) | 18 | 38 | 54 | 70 | 100 | 125 | 180 | 210 | 280 | ||
water flow(m³/h) | 0.8 | 1.7 | 2.4 | 3.2 | 4.5 | 5.5 | 7.8 | 10 | 12 | ||
pipe diameter (DN) | 25 | 32 | 40 | 40 | 40 | 40 | 50 | 50 | 65 | ||
4 Rows | Return air(kw) | 28 | 56 | 80 | 110 | 140 | 200 | 250 | 320 | 380 | |
water flow(m³/h) | 1.2 | 2.4 | 3.5 | 4.8 | 6.3 | 9 | 11 | 13.5 | 18.2 | ||
all fresh air(kw) | 32 | 62 | 90 | 125 | 150 | 220 | 300 | 380 | 450 | ||
water flow(m³/h) | 1.5 | 2.7 | 3.8 | 5.4 | 6.8 | 9.5 | 13.5 | 16.2 | 19.5 | ||
pipe diameter (DN) | 32 | 32 | 40 | 40 | 40 | 50 | 50 | 65 | 65 | ||
Function section outside dimension | Mixing section | Length(mm) | 500 | 500 | 500 | 550 | 600 | 800 | 800 | 800 | 800 |
Width(mm) | 950 | 950 | 1080 | 1250 | 1600 | 1600 | 2000 | 2200 | 2200 | ||
Height(mm) | 980 | 980 | 1080 | 1250 | 1320 | 1470 | 1680 | 1880 | 2200 | ||
Pre-filter section | Length(mm) | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | |
Width(mm) | 950 | 950 | 1080 | 1250 | 1600 | 1600 | 2000 | 2200 | 2200 | ||
Height(mm) | 980 | 980 | 1080 | 1250 | 1320 | 1470 | 1680 | 1880 | 2200 | ||
Medium efficiency filter section | Length(mm) | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 | |
Width(mm) | 950 | 950 | 1080 | 1250 | 1600 | 1600 | 2000 | 2200 | 2200 | ||
Height(mm) | 980 | 980 | 1080 | 1250 | 1320 | 1470 | 1680 | 1880 | 2200 | ||
Cooling coil section | Length(mm) | 600 | 600 | 700 | 700 | 700 | 800 | 800 | 1000 | 1000 | |
Width(mm) | 950 | 950 | 1080 | 1250 | 1600 | 1600 | 2000 | 2200 | 2200 | ||
Height(mm) | 980 | 980 | 1080 | 1250 | 1320 | 1470 | 1680 | 1880 | 2200 | ||
Heating section | Length(mm) | 300 | 300 | 300 | 400 | 400 | 400 | 400 | 400 | 400 | |
Width(mm) | 950 | 950 | 1080 | 1250 | 1600 | 1600 | 2000 | 2200 | 2200 | ||
Height(mm) | 980 | 980 | 1080 | 1250 | 1320 | 1470 | 1680 | 1880 | 2200 | ||
Humidifying section | Length(mm) | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | |
Width(mm) | 950 | 950 | 1080 | 1250 | 1600 | 1600 | 2000 | 2200 | 2200 | ||
Height(mm) | 980 | 980 | 1080 | 1250 | 1320 | 1470 | 1680 | 1880 | 2200 | ||
Fan section | Length(mm) | 500 | 500 | 900 | 400 | 1100 | 1400 | 1600 | 1700 | 1850 | |
Width(mm) | 950 | 950 | 1080 | 1250 | 1600 | 1600 | 2000 | 2200 | 2200 | ||
Height(mm) | 980 | 980 | 1080 | 1250 | 1320 | 1470 | 1680 | 1880 | 2200 | ||
Current balance section | Length(mm) | 400 | 400 | 500 | 900 | 500 | 600 | 600 | 600 | 700 | |
Width(mm) | 950 | 950 | 1080 | 1250 | 1600 | 1600 | 2000 | 2200 | 2200 | ||
Height(mm) | 980 | 980 | 1080 | 1250 | 1320 | 1470 | 1680 | 1880 | 2200 | ||
Sound deadening section | Length(mm) | 800 | 800 | 800 | 500 | 800 | 1000 | 1000 | 1000 | 100 | |
Width(mm) | 950 | 950 | 1080 | 1250 | 1600 | 1600 | 2000 | 2200 | 2200 | ||
Height(mm) | 980 | 980 | 1080 | 1250 | 1320 | 1470 | 1680 | 1880 | 2200 | ||
Air outlet section | Length(mm) | 400 | 400 | 400 | 800 | 500 | 600 | 600 | 800 | 800 | |
Width(mm) | 950 | 950 | 1080 | 1250 | 1600 | 1600 | 2000 | 2200 | 2200 | ||
Height(mm) | 980 | 980 | 1080 | 1250 | 1320 | 1470 | 1680 | 1880 | 2200 |
2. Heating condition conditions: supply and return water temp60/50℃,
indoor dry bulb/ wet bulb temp20/ -℃, fresh air dry bulb/ wet bulb temp7/6℃
3. The air volume, residual pressure and power in the table are standard parameters,
and are able to be customized
4. Heater, humidifier and heat recovery device are optional, which can be configured as spacific form according to customer's requirements
5. G4 filter is adopted as the unit standard, which can be configured as other form according to customer's requirements
6. The length and size are determined by the functional sections. Please consult us for details.
Application:
The units are widely used in the air system of many inductries like mechanical ,electronic, textile,medical,chemical,energy and foo inductries ,etc. the units are also ideal solution for restaurants, office buildings,hospitals,theaters,supermarkets and palaestra.
Packing:
Reference:
Country: Turkey Application:distributor Type: heat pump type Cooling capacity: 108.9KW; Heating capacity: 113KW; 380V-3Ph-50hz R410a ESP: 350 Pa; 19940 m3/h 25% fresh air; | Country: Nigeria Application: Pharmaceutical Factory Type: heat pump type Cooling capacity: 36.2kW Heating capacity: 82kW Refrigerant: R407C Compressor: Sanyo | Country: Jordan Application: Textile Factory Type: heat pipe heat recovery type Cooling capacity: 368kW Heating capacity: 359kW Refrigerant: R410A Compressor: Copeland With heat recovery coil | Country: USA Application: Residential Type: heat pump type Cooling capacity: 5 Ton Heating capacity: Refrigerant: R410A Compressor: COP: 3.0 Power supply: 230V/3PH/60Hz |
![]() | ![]() | ![]() | ![]() |
Country:UAE Application:offshore Drilling Platform Cooling capacity: 80kw Supply air volume: 4000×2 m3/h Condensing fan: 12000m3/h Refrigerant: R407C Power supply:430V-3Ph-60Hz Evaporator & condenser type: copper tube epoxy aluminum fin | Country:Australia Application:hall Cooling capacity: 128kw Heating capacity: 135kw Capacity regulator: 0,25,50,75,100 Power supply: 415V/3PH/50hz Refrigerant:R410A | Country:China Application: Amusement park Cooling capacity: 180kw Heating capacity: 192.5kw Supply air volume: 32000m3/h ESP: 550pa Power supply: 380V/3PH/50hz Refrigerant:R22 | Country: Philippines Application: Factory Type: Fresh air type Cooling capacity:21.9kw Heating capacity:25kw Supply air volume: 3000m3/h Electric heating: 6kw Power supply:220v/3PH/60hz 10% fresh air Refrigerant:R410A |
![]() | ![]() | ![]() | ![]() |
Country: China Application: Rolling bearing manufacturer Type: wheel heat recovery type One model: Cooling capacity: 95kw Condensation and heating capacity: 55kw Supply air volume: 19000m3/h Exhaust air volume: 19000m3/h Another model: Cooling capacity: 210kw Heating capacity: 215kw Supply air volume: 38000m3/h Exhaust air volume: 38000m3/h | Country: China Application:Flight simulation system laboratory Cooling capacity:10kw Supply air volume:3000m3/h Power supply: 380V/3PH/50Hz | Country: China Application:Ferry waiting hall Type: heat pump type Cooling capacity:182.5kw Supply air volume: 22000m3/h | Country: China Application: Cool Storehouse Type: constant temperature and constant humidity unit One model: Cooling capacity: 22kW Electric heating capacity: 82kW Humidifying capacity: 6kg/h Supply air: 4500 m3/h Another model: Cooling capacity: 180kW Electric heating capacity: 90kW Humidifying capacity: 30kg/h Supply air: 35000 m3/h |
![]() | ![]() | ![]() | ![]() |
Company Details
Business Type:
Manufacturer
Year Established:
2009
Employee Number:
>100
Ecer Certification:
Active Member
Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ... Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ...
Get in touch with us
Leave a Message, we will call you back quickly!