Payment Terms | T/T, Western Union |
Supply Ability | 100 Units Per Month |
Delivery Time | 35~40days |
Packaging Details | Plywood wooden box or pallet |
Type | Chilled water type |
Air cooled or water cooled | Air cooled |
Heater type | Steam or water coil |
Structure type | Cabinet/ ceiling / vertical / horizontal type |
Fan type | Direct drive motor or belt-driven |
Application | hotels, theaters, shopping malls, office buildings |
Air volume | 2000~50000m³/h |
Optional installation accessories | Air valve, air duct or air grill |
Brand Name | Shenglin |
Model Number | SL-ZKW Series |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
Purification Clean Room Chilled Water Air Handling Units
Cabinet Ceiling Chilled Water Air Handlers With Direct Drive Motor
Air Cooled DX Air Handling Units G4 Filters Commercial Air Handler
Constant Temperature Humidity Chilled Water AHU For Hospital Operating Room
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 100 Units Per Month |
Delivery Time | 35~40days | Packaging Details | Plywood wooden box or pallet |
Type | Chilled water type | Air cooled or water cooled | Air cooled |
Heater type | Steam or water coil | Structure type | Cabinet/ ceiling / vertical / horizontal type |
Fan type | Direct drive motor or belt-driven | Application | hotels, theaters, shopping malls, office buildings |
Air volume | 2000~50000m³/h | Optional installation accessories | Air valve, air duct or air grill |
Brand Name | Shenglin | Model Number | SL-ZKW Series |
Certification | CE | Place of Origin | China |
High Light | 50000m3/h Clean Room Air Handling Units ,dehumidifier Clean Room Air Handling Units ,50000m3 h rooftop packaged air conditioning units |
Products Features
1.Aluminum frame structure, high mechanical strength, light weight, corrosion resistance, good-looking appearance, accurate sizes. Flexible assembly structure, easily assembly and maintenance, service life is longer than the steel frame.
2.Double skin polyurethane color steel panel, no cold bridges.
3.Double air inlet centrifugal fans, by the strict dynamic and static balance test, smoothly running, small vibration. Closed rolling bearing, automatically aligning and automatically self-locking, anti-push and other functions, pre-filled with lubricating oil, normally use without maintenance.
4.Plate filter can be cleaned many times.
5.Has function of air supply, cooling, heating, dehumidifying, humidification, air filtration and noise reduction etc.
6.Suitable for the air conditioning system for electronics, instrumentation, machinery, metallurgy, chemical industry, textile, medicine, food, tobacco, transportation, energy and other industries.
Chilled Water Air Handing Unit Spec. Table No. 1 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Model SL-ZKW- | 20 | 40 | 60 | 80 | 100 | 150 | 200 | 250 | 300 | ||
Air volume(m³/h) | 2000 | 4000 | 6000 | 8000 | 10000 | 15000 | 20000 | 25000 | 30000 | ||
Outlet air pressure(pa) | 300 | 300 | 400 | 500 | 500 | 600 | 750 | 750 | 750 | ||
Supply fan capacity(kw) | 1.1 | 1.5 | 2.2 | 4 | 5.5 | 11 | 15 | 15 | 18.5 | ||
Cooling | 4 Rows | Return air(kw) | 12.2 | 23.9 | 35.9 | 48 | 60 | 90 | 120 | 150 | 179 |
water flow(m³/h) | 2.2 | 4.2 | 6.1 | 8.2 | 10.5 | 15.3 | 20.4 | 23.8 | 28.2 | ||
all fresh air(kw) | 22 | 43.8 | 62 | 90 | 112 | 156 | 210 | 265 | 310 | ||
water flow(m³/h) | 3.8 | 7.7 | 11 | 15.5 | 19.2 | 27.3 | 36.5 | 45.8 | 55 | ||
pipe diameter (DN) | 25 | 32 | 40 | 40 | 40 | 50 | 65 | 65 | 80 | ||
6 Rows | Return air(kw) | 17 | 30.1 | 45.2 | 60 | 75 | 113 | 151 | 188 | 210 | |
water flow(m³/h) | 2.8 | 5.3 | 7.7 | 10.5 | 13.6 | 19.2 | 25.5 | 30.2 | 36 | ||
all fresh air(kw) | 30.5 | 58 | 88 | 118 | 150 | 200 | 288 | 355 | 420 | ||
water flow(m³/h) | 5.1 | 10 | 15.2 | 20.2 | 26.2 | 35.5 | 49 | 70 | 72.5 | ||
pipe diameter (DN) | 32 | 32 | 40 | 40 | 50 | 65 | 65 | 80 | 80 | ||
8 Rows | Return air(kw) | 18.3 | 35.2 | 53 | 70 | 90 | 132 | 176 | 220 | 264 | |
water flow(m³/h) | 3.2 | 6.2 | 8.9 | 12.2 | 16.2 | 22.2 | 30.2 | 37.2 | 44.2 | ||
all fresh air(kw) | 34.8 | 70 | 101 | 138 | 178 | 245 | 332 | 410 | 500 | ||
water flow(m³/h) | 5.8 | 12 | 17.5 | 23.5 | 30.8 | 42.5 | 57.1 | 71 | 85 | ||
pipe diameter (DN) | 32 | 32 | 40 | 40 | 50 | 65 | 65 | 80 | 80 | ||
Heating | 2 Rows | Return air(kw) | 20 | 42 | 60 | 84 | 108 | 150 | 200 | 250 | 300 |
water flow(m³/h) | 0.8 | 1.9 | 2.6 | 3.7 | 4.6 | 6.5 | 8.7 | 11 | 13 | ||
all fresh air(kw) | 18 | 38 | 54 | 70 | 100 | 125 | 180 | 210 | 280 | ||
water flow(m³/h) | 0.8 | 1.7 | 2.4 | 3.2 | 4.5 | 5.5 | 7.8 | 10 | 12 | ||
pipe diameter (DN) | 25 | 32 | 40 | 40 | 40 | 40 | 50 | 50 | 65 | ||
4 Rows | Return air(kw) | 28 | 56 | 80 | 110 | 140 | 200 | 250 | 320 | 380 | |
water flow(m³/h) | 1.2 | 2.4 | 3.5 | 4.8 | 6.3 | 9 | 11 | 13.5 | 18.2 | ||
all fresh air(kw) | 32 | 62 | 90 | 125 | 150 | 220 | 300 | 380 | 450 | ||
water flow(m³/h) | 1.5 | 2.7 | 3.8 | 5.4 | 6.8 | 9.5 | 13.5 | 16.2 | 19.5 | ||
pipe diameter (DN) | 32 | 32 | 40 | 40 | 40 | 50 | 50 | 65 | 65 | ||
Function section outside dimension |
Mixing section | Length(mm) | 500 | 500 | 500 | 550 | 600 | 800 | 800 | 800 | 800 |
Width(mm) | 950 | 950 | 1080 | 1250 | 1600 | 1600 | 2000 | 2200 | 2200 | ||
Height(mm) | 980 | 980 | 1080 | 1250 | 1320 | 1470 | 1680 | 1880 | 2200 | ||
Pre-filter section | Length(mm) | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | |
Width(mm) | 950 | 950 | 1080 | 1250 | 1600 | 1600 | 2000 | 2200 | 2200 | ||
Height(mm) | 980 | 980 | 1080 | 1250 | 1320 | 1470 | 1680 | 1880 | 2200 | ||
Medium efficiency filter section | Length(mm) | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 | |
Width(mm) | 950 | 950 | 1080 | 1250 | 1600 | 1600 | 2000 | 2200 | 2200 | ||
Height(mm) | 980 | 980 | 1080 | 1250 | 1320 | 1470 | 1680 | 1880 | 2200 | ||
Cooling coil section | Length(mm) | 600 | 600 | 700 | 700 | 700 | 800 | 800 | 1000 | 1000 | |
Width(mm) | 950 | 950 | 1080 | 1250 | 1600 | 1600 | 2000 | 2200 | 2200 | ||
Height(mm) | 980 | 980 | 1080 | 1250 | 1320 | 1470 | 1680 | 1880 | 2200 | ||
Heating section | Length(mm) | 300 | 300 | 300 | 400 | 400 | 400 | 400 | 400 | 400 | |
Width(mm) | 950 | 950 | 1080 | 1250 | 1600 | 1600 | 2000 | 2200 | 2200 | ||
Height(mm) | 980 | 980 | 1080 | 1250 | 1320 | 1470 | 1680 | 1880 | 2200 | ||
Humidifying section | Length(mm) | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | |
Width(mm) | 950 | 950 | 1080 | 1250 | 1600 | 1600 | 2000 | 2200 | 2200 | ||
Height(mm) | 980 | 980 | 1080 | 1250 | 1320 | 1470 | 1680 | 1880 | 2200 | ||
Fan section | Length(mm) | 500 | 500 | 900 | 400 | 1100 | 1400 | 1600 | 1700 | 1850 | |
Width(mm) | 950 | 950 | 1080 | 1250 | 1600 | 1600 | 2000 | 2200 | 2200 | ||
Height(mm) | 980 | 980 | 1080 | 1250 | 1320 | 1470 | 1680 | 1880 | 2200 | ||
Current balance section | Length(mm) | 400 | 400 | 500 | 900 | 500 | 600 | 600 | 600 | 700 | |
Width(mm) | 950 | 950 | 1080 | 1250 | 1600 | 1600 | 2000 | 2200 | 2200 | ||
Height(mm) | 980 | 980 | 1080 | 1250 | 1320 | 1470 | 1680 | 1880 | 2200 | ||
Sound deadening section | Length(mm) | 800 | 800 | 800 | 500 | 800 | 1000 | 1000 | 1000 | 100 | |
Width(mm) | 950 | 950 | 1080 | 1250 | 1600 | 1600 | 2000 | 2200 | 2200 | ||
Height(mm) | 980 | 980 | 1080 | 1250 | 1320 | 1470 | 1680 | 1880 | 2200 | ||
Air outlet section | Length(mm) | 400 | 400 | 400 | 800 | 500 | 600 | 600 | 800 | 800 | |
Width(mm) | 950 | 950 | 1080 | 1250 | 1600 | 1600 | 2000 | 2200 | 2200 | ||
Height(mm) | 980 | 980 | 1080 | 1250 | 1320 | 1470 | 1680 | 1880 | 2200 |
2. Heating condition conditions: supply and return water temp60/50℃,
indoor dry bulb/ wet bulb temp20/ -℃, fresh air dry bulb/ wet bulb temp7/6℃
3. The air volume, residual pressure and power in the table are standard parameters,
and are able to be customized
4. Heater, humidifier and heat recovery device are optional, which can be configured as spacific form according to customer's requirements
5. G4 filter is adopted as the unit standard, which can be configured as other form according to customer's requirements
6. The length and size are determined by the functional sections. Please consult us for details.
Application:
The units are widely used in the air system of many inductries like mechanical ,electronic, textile,medical,chemical,energy and foo inductries ,etc. the units are also ideal solution for restaurants, office buildings,hospitals,theaters,supermarkets and palaestra.
Company Details
Business Type:
Manufacturer
Year Established:
2009
Employee Number:
>100
Ecer Certification:
Active Member
Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ... Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ...
Get in touch with us
Leave a Message, we will call you back quickly!