Payment Terms | Western Union, T/T |
Supply Ability | 100 units per month |
Delivery Time | 30~35 days |
Packaging Details | Stretch film add pallet packing |
Refrigerant | R410A or R22 |
Compressor type | Screw |
Warranty | One year after leave the factory |
Water outlet temperature | 7 ℃ for air Conditioning working condition |
Condenser type | Fin type heat exchanger |
Evaporator type | Dry type shell and tube heat exchanger |
Cooling capacity range | 65~260kW |
Function | Cooling and heating |
Advantage | Modularization |
Keyword | Water Chiller Units |
Brand Name | Shenglin |
Model Number | SSQWRF Series |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
Copeland Packaged Industrial Water Chiller Coil Evaporator
Screw Compressor Hermetic Water Cooled Scroll Chiller Hvac
Semihermetic Evaporator Industrial Water Chiller OEM SJ Screw Type
Air Cooled Screw Type Glycol Medical Packaged Water Chiller SUS Water Tank
Product Specification
Payment Terms | Western Union, T/T | Supply Ability | 100 units per month |
Delivery Time | 30~35 days | Packaging Details | Stretch film add pallet packing |
Refrigerant | R410A or R22 | Compressor type | Screw |
Warranty | One year after leave the factory | Water outlet temperature | 7 ℃ for air Conditioning working condition |
Condenser type | Fin type heat exchanger | Evaporator type | Dry type shell and tube heat exchanger |
Cooling capacity range | 65~260kW | Function | Cooling and heating |
Advantage | Modularization | Keyword | Water Chiller Units |
Brand Name | Shenglin | Model Number | SSQWRF Series |
Certification | CE | Place of Origin | China |
High Light | R410A Dry Evaporator Water Chiller Units ,Air Cooled Hanbell Water Chiller Units ,65kw chilled water ac system |
Conventional Series Modular Air Cooled Chiller (Heat Pump)
Conventional series module unit
Water Chiller Units Features:
1. The whole system adopts high-efficiency new shell-and-tube heat exchanger: the heat exchanger core can be disassembled, cleaned and maintained conveniently;
2. Electronic expansion valve throttling: 500-step electronic expansion valve precise throttle control, dynamic matching refrigeration system, so that the unit is always in an optimal state;
3. Advanced technology: 3-way fin temperature sensor, optional humidity sensor to control defrosting;
4. Modularization: modular design is free to expand and easy to install in phases;
5. Three-level test, all products have undergone rigorous testing, product testing is divided into new product development test, factory test, regular and irregular test.
6. Reliable operation: The unit has more than 10 safety protection functions such as compressor overload protection, exhaust high temperature protection, high/low voltage protection, low water flow protection, antifreeze protection, power protection, etc. Protection system.
7. Low-temperature cooling operation: special customized, can achieve low temperature cooling under ambient temperature 5 °C, -10 °C, -20 °C.
Technical parameter:
Model | SSQWRF60M-G | SSQWRF100M-G | SSQWRF130M-G | SSQWRF200M-G | SSQWRF260M-G | |||
Ambient temperature DB/ WB | Inlet/outlet temperature | Capacity | ||||||
35℃/— | 12℃/ 7℃ | Cooling capacity | kW | 65 | 97.5 | 130 | 195 | 260 |
Input capacity | kW | 21 | 31.8 | 42.7 | 63.6 | 85.4 | ||
7℃/6℃ | 40℃/ 45℃ | Heating capacity | kW | 68 | 102 | 136 | 204 | 272 |
Input capacity | kW | 20.1 | 30.7 | 41.2 | 61.4 | 82.4 | ||
Power supply | 3N~/ 380V/ 50Hz | |||||||
Refrigerant | R22 | |||||||
Water side heat exchanger | Type | Shell and tube heat exchanger | ||||||
Cooling water flow | m3/h | 11.2 | 16.8 | 22.4 | 33.6 | 44.8 | ||
Heating water flow | m3/h | 11.7 | 17.6 | 23.4 | 35.1 | 46.8 | ||
Water resistance | kPa | 46 | 52 | 55 | 52 | 55 | ||
Connection water pipe spec. | DN | 50 |
50
|
65 | 2x50 | 2x65 | ||
Overall dimensions | L x W x H | 2000x1060x1957 | 2207x1300x2076 | 2207x1300x2076 | 2207x2207x2096 | 2207x2207x2096 | ||
Net weight | kg | 620 | 1060 | 1120 | 2160 | 2280 | ||
Running weight | kg | 635 | 1090 | 1155 | 2220 | 2350 |
Cooling condition: Chilled water inlet/outlet temperature 12/7 ℃, ambient dry bulb temperature 35℃
Heating condition:Hot water outlet temperature 45℃, ambient dry bulb temperature 7℃, ambient wet bulb temperature 6℃
Company Details
Business Type:
Manufacturer
Year Established:
2009
Employee Number:
>100
Ecer Certification:
Active Member
Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ... Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ...