Payment Terms | T/T, Western Union |
Supply Ability | 100 units per month |
Delivery Time | 30~35 days |
Packaging Details | Stretch film and Pallet for full container loading |
Tube material | 3/8 or 5/8" outer diameter copper tubes |
Fin material | Hydrophilic aluminum foil or epoxy resin aluminum foil |
Frame material | Galvanized steel plate or stainless steel |
Power supply | 380V/3P/50Hz or 380V/3P/60Hz |
Fan brand | Usually Chinese brand |
Product category | Dry Cooler For Crypto Cooling System |
Cooling way | Crypto Immersion cooling |
Advantage | Energy saving and save floor space |
Media | Electrocool dielectric coolants |
Brand Name | Shenglin |
Model Number | SHSL-D1 Series |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
Wet-Dry Coolers Direct Water Spray Two Phase Liquid Bitcoin Cooling System
Submerging Bitcoin Miners Two Phase Immersion Cooling Dry Coolers
Flat Type High Heat Transfer Efficiency Immersion Bitcoin Cooling System
Ziehl-Abegg Fan Dry Fluid Cooler Table Type Structure For Immersion Cooling
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 100 units per month |
Delivery Time | 30~35 days | Packaging Details | Stretch film and Pallet for full container loading |
Tube material | 3/8 or 5/8" outer diameter copper tubes | Fin material | Hydrophilic aluminum foil or epoxy resin aluminum foil |
Frame material | Galvanized steel plate or stainless steel | Power supply | 380V/3P/50Hz or 380V/3P/60Hz |
Fan brand | Usually Chinese brand | Product category | Dry Cooler For Crypto Cooling System |
Cooling way | Crypto Immersion cooling | Advantage | Energy saving and save floor space |
Media | Electrocool dielectric coolants | Brand Name | Shenglin |
Model Number | SHSL-D1 Series | Certification | CE |
Place of Origin | China | ||
High Light | Immersion cryptocurrency cooler ,Liquid cryptocurrency cooler ,Two phase Immersion cooler |
Two-phase Liquid Cooling Liquid Immersion Cooling Systems For Cryptocurrency Mining Farms
What's Immersion Cooling?
Also known as liquid submersion cooling. It is the practice of submerging computer components (or full servers) in a thermally, but not electrically, conductive liquid (dielectric coolant) allowing higher heat transfer performance than air and many other benefits.
Why many large data centers have already moved or are considering the move to immersion cooling?
1. Up to 25% increase in power efficiency |
2. Up to 80% cost reduction |
3. Up to 60% hashrate increase |
4. 50%+ equipment lifespan. |
Introduction of Two-phase Liquid Cooling:
The cooling liquid undergoes a phase change in the process of circulating heat dissipation. The cooling liquid takes away the heat from the server and then undergoes a phase change gasification. The gaseous cooling liquid is condensed by the condenser and becomes liquid again and returns to the liquid cooling tank; the cooling liquid can use 3M electronics The boiling point of the coolant FC-72 and FC-72 is above 50℃.
In this case, the temperature of the water in the condensing coil does not need to be too low. The use of a dry cooler can meet the heat exchange requirements and take away the heat.
The two-phase liquid cooling has a high heat transfer efficiency due to the phase change of the electronic cooling liquid.
The disadvantage is that during this phase change, the electronic fluorinated liquid will escape during the vaporization process, so there is a certain degree of tightness of the container. However, it should not be too sealed to prevent the cooling system from being interrupted and the cylinder explosion event, so certain safety facilities need to be set up.
Technical parameter
Dry cooler D1 series parameter (fin space 2.1mm)
Type | D1-005- 1x350 | D1-006- 1x350 | D1-007- 1x350 | D1-009- 1x450 | D1-011- 1x450 | D1-013- 1x450 | D1-014- 1x500 | D1-017- 1x500 | D1-020- 1x500 | ||||||
Capacity | Water | 35℃ outdoor temp. | Inlet | 45℃ | △ | KW | 4.89 | 5.9 | 6.83 | 9.39 | 10.99 | 13.33 | 14.32 | 17.01 | 19.8 |
outlet | 40℃ | Y | |||||||||||||
20% Glycol | Inlet | 45℃ | △ | 4.72 | 5.69 | 6.69 | 8.9 | 10.61 | 13.05 | 13.91 | 16.11 | 19.29 | |||
outlet | 40℃ | Y | |||||||||||||
Medium | Water flow | M3/h | 0.85 | 1.03 | 1.2 | 1.63 | 1.91 | 2.3 | 2.5 | 3 | 3.5 | ||||
Pressure drop | kPa | 36 | 31 | 58 | 25 | 40 | 80 | 50 | 60 | 40 | |||||
Air flow | △ | M3/h | 2828 | 2712 | 2492 | 6199 | 5827 | 5225 | 8469 | 8168 | 7601 | ||||
Y | |||||||||||||||
Fan motor | Phase | 1 | 1 | 1 | 3 | 3 | 3 | 3 | 3 | 3 | |||||
△ | W | 140 | 140 | 140 | 540 | 540 | 540 | 830 | 830 | 830 | |||||
Y | |||||||||||||||
△ | A | 0.6 | 0.6 | 0.6 | 1.1 | 1.1 | 1.1 | 1.45 | 1.45 | 1.45 | |||||
Y | |||||||||||||||
Fan | No X φ | 1x1x350 | 1x1x350 | 1x1x350 | 1x1x450 | 1x1x450 | 1x1x450 | 1x1x500 | 1x1x500 | 1x1x500 | |||||
Sound pressure level | △ | dB(A) | 31 | 31 | 31 | 43 | 43 | 43 | 49 | 49 | 49 | ||||
Y | 10m | ||||||||||||||
Dimension | L | mm | 870 | 870 | 870 | 1020 | 1020 | 1020 | 1220 | 1220 | 1220 | ||||
W | mm | 525 | 525 | 525 | 625 | 625 | 625 | 825 | 825 | 825 | |||||
H | mm | 797 | 797 | 797 | 820 | 820 | 820 | 870 | 870 | 870 | |||||
A | mm | 690 | 690 | 690 | 840 | 840 | 840 | 1040 | 1040 | 1040 | |||||
B | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- | |||||
C | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- | |||||
D | mm | 490 | 490 | 490 | 490 | 490 | 490 | 490 | 490 | 490 | |||||
Inlet φ | mm | 3/4” | 3/4” | 3/4” | 1” | 1” | 1” | 1-1/4” | 1-1/4” | 1-1/4” | |||||
Inlet φ | mm | 3/4” | 3/4” | 3/4” | 1” | 1” | 1” | 1-1/4” | 1-1/4” | 1-1/4” | |||||
Product weight(empty) | kg | 38 | 42 | 48 | 55 | 60 | 67 | 75 | 82 | 91 |
Note: Standard SHSL-D1 dry cooler is vertical air discharge, for horizontal air discharge please add “H” in nomenclature, for excmple:SHSL-D1-005H-1X350
Some data center cooling reference:
For data center cooling:
Country: Mongolia Application: match with precision air conditioner Cooling capacity: 17.6kW Cooling medium: 34% ethylene glycol Supply power: 400V/3P/50Hz Fan brand: Ziehl-Abegg | Country: Russia Application:data center cooling Cooling capacity: 763kW Cooling medium: water Supply power: 380V/3P/50Hz Fan brand: Ziehl-Abegg |
| |
The immersion cooling system diagram by dry cooler/dry cooling tower:
Company Details
Business Type:
Manufacturer
Year Established:
2009
Employee Number:
>100
Ecer Certification:
Active Member
Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ... Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ...