Payment Terms | T/T, Western Union |
Supply Ability | 100 units per month |
Delivery Time | 35~40days |
Packaging Details | Stretch film and Pallet |
Tube material | Copper tubes |
Fin material | Hydrophilic aluminum foil or epoxy resin aluminum foil |
Frame material | Galvanized steel plate or stainless steel |
Power supply | 380V/3P/50Hz or 380V/3P/60Hz |
Fan brand | Ziehl-Abegg |
Frame painting colour | White or gray |
Product category | Dry Cooler |
Cooling way | Immersed Cooling |
Structure | Table type |
Media | Electrocool dielectric coolants |
Brand Name | Shenglin |
Model Number | H*FS Series |
Certification | CE and Rohs |
Place of Origin | China |
View Detail Information
Explore similar products
5~800kw Submerging Mining Farm Cooling System Bitcoin Cooler Unit
Blockchain Miners Liquid Submersion Cooling System Dry Cooling Tower
CE Submerged Cooling Data Center Immersion Cooling Dry Coolers
2 Phase Submerged Immersed Server Cooling System For Datacenters
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 100 units per month |
Delivery Time | 35~40days | Packaging Details | Stretch film and Pallet |
Tube material | Copper tubes | Fin material | Hydrophilic aluminum foil or epoxy resin aluminum foil |
Frame material | Galvanized steel plate or stainless steel | Power supply | 380V/3P/50Hz or 380V/3P/60Hz |
Fan brand | Ziehl-Abegg | Frame painting colour | White or gray |
Product category | Dry Cooler | Cooling way | Immersed Cooling |
Structure | Table type | Media | Electrocool dielectric coolants |
Brand Name | Shenglin | Model Number | H*FS Series |
Certification | CE and Rohs | Place of Origin | China |
High Light | Datacenters submerged server cooling ,dielectric coolants submerged server cooling ,dielectric coolants submerged liquid cooling |
Flat Series Dielectric Coolants Datacenters Submerged Server Cooling Dry Coolers
What's ImmersedCooling?
Immersion cooling is an IT cooling practice by which IT components and other electronics, including complete servers, are submerged in a thermally conductive dielectric liquid or coolant. Heat is removed from the system by circulating liquid into direct contact with hot components, then through cool heat exchangers. Fluids suitable for immersion cooling have very good insulating properties to ensure that they can safely come into contact with energized electronic components.
Benefits of Immersed Cooling:
Reduce Operating Costs by 50%+
Power reduction by removing the fans from the miners (~18% – 25%)
Removal of supplementary cooling systems (Intake / Exhaust fans, etc. account for another 20% – 25%)
Increase the hash rate of your current equipment
Increase hardware lifespan
Increase the density of miners in your facility
Built in fire protection as our dielectric fluid is non-flammable
Immersion cooling systems do not require chillers, CRAC units, raised flooring, etc
Many more!
With our Immersed Cooling System, servers are immersed in closed containers in a non-toxic, non-conductive liquid and the heat is dissipated quickly and effectively, resulting in a cooling capacity of more than 2000X that of air cooling.As a result, electricity consumption decreases by 90%, and the performance of the servers increases by 250%.
Our proprietary solution enables customers to host their service in a fully controllable environment. Two-phase cooling allows for a much higher density than standard air cooling, and consumes much less space, allowing datacenters to become more efficient, reduce their power consumption by 60% and increase density.
Two-phase liquid cooling:
The cooling liquid undergoes a phase change in the process of circulating heat dissipation. The cooling liquid takes away the heat from the server and then undergoes a phase change gasification. The gaseous cooling liquid is condensed by the condenser and becomes liquid again and returns to the liquid cooling tank; the cooling liquid can use 3M electronics The boiling point of the coolant FC-72 and FC-72 is above 50℃. In this case, the temperature of the water in the condensing coil does not need to be too low. The use of a dry cooler can meet the heat exchange requirements and take away the heat. The two-phase liquid cooling has a high heat transfer efficiency due to the phase change of the electronic cooling liquid. The disadvantage is that during this phase change, the electronic fluorinated liquid will escape during the vaporization process, so there is a certain degree of tightness of the container. However, it should not be too sealed to prevent the cooling system from being interrupted and the cylinder explosion event, so certain safety facilities need to be set up.
Some Reference:
Country: Mongolia Application: match with precision air conditioner Cooling capacity: 17.6kW Cooling medium: 34% ethylene glycol Supply power: 400V/3P/50Hz Fan brand: Ziehl-Abegg | Country: Russia Application:data center cooling Cooling capacity: 763kW Cooling medium: water Supply power: 380V/3P/50Hz Fan brand: Ziehl-Abegg |
| |
Company Details
Business Type:
Manufacturer
Year Established:
2009
Employee Number:
>100
Ecer Certification:
Active Member
Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ... Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ...