Payment Terms | T/T, Western Union |
Supply Ability | 100 units per month |
Delivery Time | 30~35days |
Packaging Details | Stretch film and Pallet |
Tube material | Copper tubes |
Fin material | Hydrophilic aluminum foil or epoxy resin aluminum foil |
Frame material | Galvanized steel plate or stainless steel |
Power supply | 380V/3P/50Hz or 380V/3P/60Hz |
Fan brand | EBM or Ziehl-Abegg |
Frame painting colour | White |
Product category | Air Dry Coolers |
Cooling way | Immersion cooling |
Media | Electrocool dielectric coolants |
Brand Name | Shenglin |
Model Number | SHSL-D3 Series |
Certification | CE |
Place of Origin | China |
View Detail Information
Explore similar products
EC Type Fan Dry Cooler Bitcoin Server Immersion Cooling System
800mm Ziehl-Abegg EC Fan Immersion Cooling Data Center Air Dry Coolers
Server Immersion Cooling Dielectric Coolants Bitcoin Cooler Unit
BTC GPUs Dielectric Fluid Submerged Server Cooling System
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 100 units per month |
Delivery Time | 30~35days | Packaging Details | Stretch film and Pallet |
Tube material | Copper tubes | Fin material | Hydrophilic aluminum foil or epoxy resin aluminum foil |
Frame material | Galvanized steel plate or stainless steel | Power supply | 380V/3P/50Hz or 380V/3P/60Hz |
Fan brand | EBM or Ziehl-Abegg | Frame painting colour | White |
Product category | Air Dry Coolers | Cooling way | Immersion cooling |
Media | Electrocool dielectric coolants | Brand Name | Shenglin |
Model Number | SHSL-D3 Series | Certification | CE |
Place of Origin | China | ||
High Light | Crypto Mining Immersion Cooling System ,CST Immersion Cooling System ,OEM Crypto Mining cooling system |
OEM CST Dry Cooler Air Cooled Condenser for Crypto Mining Immersion Cooling System
What's Immersion Cooling?
Also known as liquid submersion cooling. It is the practice of submerging computer components (or full servers) in a thermally, but not electrically, conductive liquid (dielectric coolant) allowing higher heat transfer performance than air and many other benefits.
Traditionally, air-cooled methods require raised floor systems that allow for cold air to be pumped to servers via computer room air conditioners (CRAC). This traditional method proves to be inefficient when cooling increased compute loads and higher watts per square foot. The majority of legacy and enterprise data centers today utilize air-cooled systems.
One item that remains clear is that as servers demand more power and generate more heat, liquid cooling is emerging as the leader in more efficient cooling practices. Increasingly, the deployment of immersion cooling is what separates the data center technology leaders from the rest of the pack.
Why Choose us
Professional system integration Customized size Thermodynamic calculations Authoritative seismic design Integrated wet curtain celdek7090 | Frame: Galvanized sheet sprayed (rai 7035) Hot dip galvanized sheet Stainless steel plate Galvanized sheet | AC-EC fan: Protection grade ip55 Low energy consumption Inverter control High temperature resistant fan Explosion-proof fan | Various diameter fans are available: 800, 1~14 psc 910, 1~18 psc 1250, 1~8 psc 1800, 1~7 psc |
Pipe: Copper Copper nickel alloy Stainless steel Titanium | Fin: Epoxy coating Aluminum Copper: Tinned copper foil Blygold coating Stainless steel Titanium | Overhaul and cleaning: Easy to clean Optional access door or hinged fan panel Fin form for easy cleaning Robust material with high mechanical strength Easy to maintain | Different connection options: Flange connection Threaded connection Welding |
Technical parameter of dry coolers
FLAT SERIES SINGLE ROW FANS
H*FS*91 H*FS*125 H*FS*180 | Van Dim mm | * | H*FS191 H*FS1125 H*FS1180 | H*FS291 H*FS2125 H*FS2180 | H*FS391 H*FS3125 H*FS3180 | H*FS491 H*FS4125 H*FS4180 | H*FS591 H*FS5125 H*FS5180 | H*FS691 H*FS6125 H*FS6180 | H*FS791 H*FS712 H*FS7180 | H*FS891 H*FS8125 H*FS8180 |
Rated Capacities (kW) Heat Exchange Surface (㎡) | ||||||||||
Fluid Coolers | 910 | D | 61kW-648kW 120㎡-2307㎡ (Water/Ta25℃/Tin40℃/Tout35℃) | |||||||
1250 | 138kW-1528kW 302㎡-4542㎡ (Water/Ta25℃/Tin40℃/Tout35℃) | |||||||||
1800 | 198kW-1920kW 363㎡-5084㎡ (Water/Ta25℃/Tin40℃/Tout35℃) | |||||||||
Freon Condensers | 910 | F | 73kW-764kW 120㎡-2307㎡ (R404A/Ta35℃/Tk50℃) | |||||||
1250 | 166kW-1549kW 302㎡-4842㎡ (R404A/Ta35℃/Tk50℃) | |||||||||
1800 | 230kW-1920kW 330㎡-5103㎡ (R404A/Ta35℃/Tk50℃) | |||||||||
Ammonia Condensers | 910 | A | 72kW-779kW 141㎡-2721㎡ (NH3/Ta35℃/Tk50℃ ) | |||||||
1250 | 181kW-1554kW 351㎡-5625㎡ (NH3/Ta35℃/Tk50℃ ) | |||||||||
1800 | 262kW-1986kW 421㎡-5907㎡ (NH3/Ta35℃/Tk50℃ ) | |||||||||
Gas Coolers | 910 | G | 49kW-862kW 96㎡-1824㎡ ( CO2/Tair32℃/Tin113℃/P94Bar/Tout34℃) | |||||||
Oil Coolers | 910 | O | 49kW-1041kW 120㎡-2307㎡ (OIL ISO VG 46/Ta35℃/Tin85℃/Tout60℃) | |||||||
1250 | 75kW-2021kW 302㎡-4842㎡ (OIL ISO VG 46/Ta35℃/Tin85℃/Tout60℃) | |||||||||
1800 | 92kW-2505kW 330㎡-5103㎡ (OIL ISO VG 46/Ta35℃/Tin85℃/Tout60℃) | |||||||||
Fan Model | 910 | EC | W3G910KU2503 (2.55kW) or FN091-ZIQ.GL.V5P1 (3.2kW) | |||||||
910 | AC | W6D910GB0101 (2.02kW) or FN091-SDS.6N.V7P2 (1.85kW) | ||||||||
1250 | EC | 160M2-8P-5.5kW/720RPM/1250_5-5_LP_39°_PPG_9W2L | ||||||||
1250 | AC | 160M2-8P-5.5kW/720RPM/1250_5-5_LP_39°_PPG_9W2L | ||||||||
No of Fans | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | ||
Overall Dimensions | 910 | Lenth-1 | 1980 | 3480 | 4980 | 6480 | 7980 | 9480 | 10980 | 12480 |
Lenth-2 | 2280 | 4080 | 5880 | 7680 | 9480 | 11280 | 13080 | 14880 | ||
Width | 1230 | |||||||||
Height | 1740 (Including 800Leg) | |||||||||
1250 | Lenth | 2600 | 4600 | 6600 | 8600 | 10600 | 12600 | 14600 | 16600 | |
Width | 2280 | |||||||||
Height | 1970 (Including 800Leg) | |||||||||
1800 | Lenth | 3000 | 5400 | 7800 | 10200 | 12600 | 15000 | 17400 | // | |
Width | 2280 | |||||||||
Height | 2170 (Including 1000Leg) |
Packing and loading:
![]() | ![]() |
![]() | ![]() |
Some reference:
Dry cooler case | |
Case 1: used in chemical plant. | Case 2: used in chemical plant. Refrigerant: ethylic acid(flow: 372 ton/h) |
![]() ![]() | ![]() ![]() |
Case 3: used in communication station as air conditioner outdoor unit in China. | Case 4: used in communication station as air conditioner outdoor unit |
![]() | ![]() |
Company Details
Business Type:
Manufacturer
Year Established:
2009
Employee Number:
>100
Ecer Certification:
Active Member
Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ... Introduction: Shanghai Shenglin is a professional manufacturer and sales of heat exchanger and air conditioning unit since 2009, located in Shanghai, China. Shanghai Shenglin was established in 2009, at the beginning only do HVAC international trading, then from 2012, we ...