Payment Terms | L/C, T/T, Western Union,paypal |
Supply Ability | 20 units per month |
Delivery Time | 7-15days |
Packaging Details | Wooden box |
Membrane Vessel | FRP or Stainless Steel/ UPVC |
Warranty | 1 YEARS |
Maximum pressure drop | 15psig(1.0bar) |
Desalination Rate | 98%-99.5% |
Technology | EDI, RO, HP pump, Chlorine dosing , UV |
Pump | CNP / Grundfos/Pulsafeeder |
Brand Name | CHUNKE |
Model Number | CK-EDI |
Certification | CE,ISO |
Place of Origin | CHINA |
View Detail Information
Explore similar products
Portable Mobile EDI Machine Containerized Seawater Desalination Plant
Industrial EDI Water Treatment Plant SS Water Desalination For Medicine
Stainless Steel EDI Water Treatment Plant , Electrodeionization Water Treatment
Automatic EDI Water Treatment System / EDI Water Plant Pure Water Process
Product Specification
Payment Terms | L/C, T/T, Western Union,paypal | Supply Ability | 20 units per month |
Delivery Time | 7-15days | Packaging Details | Wooden box |
Membrane Vessel | FRP or Stainless Steel/ UPVC | Warranty | 1 YEARS |
Maximum pressure drop | 15psig(1.0bar) | Desalination Rate | 98%-99.5% |
Technology | EDI, RO, HP pump, Chlorine dosing , UV | Pump | CNP / Grundfos/Pulsafeeder |
Brand Name | CHUNKE | Model Number | CK-EDI |
Certification | CE,ISO | Place of Origin | CHINA |
High Light | ro edi plant ,electrodeionization water treatment |
1000liter RO+EDI Module Water Treatment Equipment With SEKO Pump/CIP System
1000L/H Two-stage RO Configuration list
Equipment name | 1000L/H two-stage RO | ||||
No. | Accessories name | Specification | Quantity | Unit | Brand |
1 | Original water tank 304 stainless steel / PE anti-corrosion | (Customer supply) | 1 | SET | |
2 | Original water pump | 1 | SET | CNP | |
3 | Mechanical filter | 1 | SET | CHUNKE | |
4 | Activated carbon filter | 1 | SET | CHUNKE | |
5 | Water softener | 1 | SET | CHUNKE | |
6 | PH adjustment dosing system | 1 | SET | SEKO | |
7 | 5μm security filter | 1 | SET | CHUNKE | |
8 | High pressure pump | 1 | SET | CNP | |
9 | Two-stage reverse osmosis pure water device Water production: 1.0m3/h, salt rejection: 97~99% | 1 | SET | CHUNKE | |
10 | RO water tank PE anti-corrosion | 1 | SET | CHUNKE | |
11 | EDI feed water pump | 1 | SET | CNP | |
12 | 0.22μm precision filter | 1 | SET | CHUNKE | |
13 | EDI deionization device, water production: 1.0m3/h, water quality: conductivity ≤0.2us/cm | 1 | SET | CHUNKE | |
14 | EDI ultra-pure water tank | PE anti-corrosion | 1 | SET | CHUNKE |
15 | Connecting pipe fittings (food grade UPVC pipe valve parts are used from the original water tank outlet to the terminal fine filter outlet, and 304 stainless steel outer polished pipe valve parts are used for the reverse osmosis high pressure part.) | 1 | SET | CHINA | |
16 | Electronic control system | 1 | SET | CHUNKE | |
17 | Pressure gauge | 1 | SET | CHINA | |
18 | Panel flowmeter (0-10GPM) | 1 | SET | CHINA |
EDI module water requirements:
Each of the following indicators is the minimum necessary condition to ensure the normal operation of EDI. In order to make the system run better, the system should be designed to increase the water supply requirements.
1, Water supply: reverse osmosis water production
2, TEA (total exchangeable anion, calculated as CaCO): <35 ppm.
TEA includes all anions and substances that are removed by EDI in an anionic form. Since CO2, SiO2 and HBO3 contained in water are HCO2/CO2, HSiO/SiOg2- and B(OH).
The form is cleared by EDI, and when the TEA is calculated empirically, the charges are -1.7, -1.5, and -1.0, respectively. Some of the HCO3 in the feed water is also removed in the form of CO2-, and the charge is also calculated in -1.7 when calculating TEA. The TEA calculation formula is as follows:
TEA=50[Cc1/35.5 2Cs0*/96 1.7Cco/44 1.7Cco-/61 1.5Csi0/60
...J where all substance concentrations are in mg/L.
3, pH: 6.0-9.0 When the total hardness is less than 0.1ppm, the optimal working pH range of EDI is 8.0~9.0.
The pH value is a reference indicator for water supply, and it is one of the indicators that indirectly reflects the CO content of the feed water.
4, temperature: 5-35
5, Inlet pressure: <0.4MPa (60psi).
The inlet pressure of the concentrated/polar water is generally lower than the outlet pressure of the product water by 0.03-0.05 MPa.
6, Hardness (calculated as CaCO): <10.0 ppm.
Note: The EDI process requires a defined inlet hardness to avoid fouling. The water hardness is less than 10.0
At the ppm, the CanpureTM Super EDI system has a water utilization of 90%. Excessive pursuit of higher water utilization is of little significance because the 100% concentrated water and polar water of the EDI system can be reused before returning to reverse osmosis.
7, Organic matter (TOC): <0.5 ppm.
8, Oxidizer: Cl2<0.05ppm, O<0.02ppm.
9, Valence metal: Fe<0.01ppm, Mn<0.01ppm.
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2009
Total Annual:
50000000-10000000
Employee Number:
200~500
Ecer Certification:
Active Member
Guangzhou Chunke Environmental Technology Co., Ltd. was established in 2009 is located in Guangzhou Baiyun District Junhe Street, near Guangzhou Baiyun International Airport, an independent mechanical processing, production, commissioning, testing, packaging workshop and spacious office building, th... Guangzhou Chunke Environmental Technology Co., Ltd. was established in 2009 is located in Guangzhou Baiyun District Junhe Street, near Guangzhou Baiyun International Airport, an independent mechanical processing, production, commissioning, testing, packaging workshop and spacious office building, th...
Get in touch with us
Leave a Message, we will call you back quickly!