Supply Ability | 1 Set/Sets per Month |
Packaging Details | wooden case |
Type | RC Filter |
Transfer Function | Low Pass |
Package Type | Surface Mount |
Nominal Center Frequency | 50Hz |
3dB Bandwidth | 10M |
Insertion Loss | 100dB |
Input Impedance | 50oHm |
Stopband Attenuation | 100dB |
power supply | single phase three phase or dc |
Usage | emc test |
Room size | customized |
door size | customized |
Panel | 2mm/3mm steel panel |
attenuation | 14KHz-40GHz >=100dB |
Packing | wooden case |
Delivery time | 2-3weeks for emc testing Electromagnetic shielding RF room |
Port | shanghai |
Model Number | H |
Brand Name | haozhuo |
Certification | CE RoHS |
View Detail Information
Explore similar products
Anechoic Chamber EMI Honeycomb Vents
Emi Air Vent Filter panel
Emi Rfi Shielded Waveguide Air Vents
RF Attenuation 100db Microwave RF Shielding Room Radio Frequency Test
Product Specification
Supply Ability | 1 Set/Sets per Month | Packaging Details | wooden case |
Type | RC Filter | Transfer Function | Low Pass |
Package Type | Surface Mount | Nominal Center Frequency | 50Hz |
3dB Bandwidth | 10M | Insertion Loss | 100dB |
Input Impedance | 50oHm | Stopband Attenuation | 100dB |
power supply | single phase three phase or dc | Usage | emc test |
Room size | customized | door size | customized |
Panel | 2mm/3mm steel panel | attenuation | 14KHz-40GHz >=100dB |
Packing | wooden case | Delivery time | 2-3weeks for emc testing Electromagnetic shielding RF room |
Port | shanghai | Model Number | H |
Brand Name | haozhuo | Certification | CE RoHS |
High Light | Microwave Anechoic Chamber ,Fully Anechoic Chamber ,Fully Anechoic Room |
14KHz-40GHz more than 100dB for data/voice security EMI anechoic chamber
When a shielded room is necessary?
· If your lab is near a broad spectrum emitter (i.e equipment that transmits multiple frequencies under 400Hz), radio tower, mobile phone transmitter or other large field generators, then you should consider a shielded room.
· If your research is in the gamma band and you do not want to use a 60/50Hz notch filter to remove mains power noise, you might consider a shielded room. We recommend taking the steps above to first minimize the mains power noise. If that is not sufficient for your needs, then a shielded room may help.
Product Features | ||||
Shielding panels are made of molded cold-rolled steel plates. They are jointed in way and welded with CO2 protection, which can restrain the plates from distortion and ensure the leveling of the steel plates. | ||||
Self-supported frame construction is made of section materials. | ||||
Shielding door is optional: standard electromotive door (electromotive / manual alternative), full-automatic shielding door (light-activated with password) sliding door. Subshining stainless steel decoration is on surface of the door. Standard dimension of the door is:0.85×2(m). | ||||
Large-scale hanging sliding shielding-door, electromotive sliding push-in door, electromotive sliding gasbag door, rotated door with track. | ||||
Ventilated window is designed in cellular wave-guide type with dimension:300×300(mm). | ||||
Power filter is in condition of high-performance and low-leakage. | ||||
Telephone, air-conditioning, fire-fight devices, optical fiber and CAT5 cables can be equipped customized. | ||||
Decoration will be arranged in the shielding room according to standard equipment room requirements. | ||||
Shielding Properties (dB) | ||||
Magnetic field | 14kHz | 85dB | ||
100KHz | 100dB | |||
200KHz | 110dB | |||
Plane wave | 50-103MHz | 120dB | ||
Microware | 1-10GHz | 110dB | ||
10-20GHz | 100dB | |||
20-40GHz | 80dB | |||
Application Scope | ||||
EMC tesing | ||||
Items 1 | Module Panel type, 2mm/3mm galvanized steel plate |
| ||
Items 2 | RF Shielding Door, Open size:1000*2000mm |
| ||
Items 3 | Power Filters |
| ||
Items 4 | Honeycomb Ventilation panels |
| ||
Items 5 | RF Panel |
| ||
Items 6 | Floor |
| ||
Items 7 | Foam RF absorber |
| ||
Items 8 | Beryllium copper Fingers |
| ||
Items 9 | Steel waveguide |
| ||
Items 10 | EMI Shielding Gasket |
|
RF Anechoic chamber Shielding Properties (dB) | ||
Magnetic field | 14kHz | 75dB |
100KHz | 100dB | |
200KHz | 110dB | |
Plane wave | 50-103MHz | 120dB |
Microware | 1-10GHz | 110dB |
10-20GHz | 100dB |
Company Details
Business Type:
Manufacturer
Year Established:
2012
Total Annual:
1000000-1500000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
We are a professional and famous EMI filter manufacturer. Our technical team has more than 10 years’ experience in designing EMI filter. We know UL VDE CSA CE CQC etc safety standard very well. Our technical service team learn many kinds of test standard such as industrial application (I... We are a professional and famous EMI filter manufacturer. Our technical team has more than 10 years’ experience in designing EMI filter. We know UL VDE CSA CE CQC etc safety standard very well. Our technical service team learn many kinds of test standard such as industrial application (I...
Get in touch with us
Leave a Message, we will call you back quickly!