Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Agilent Keysight 34470A Digital Multimeter 7.5 Digit Truevolt DMM Benchtop \/","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/04\/71\/ad558b228b17cc389a61ebb05c18-200x200-1\/agilent_keysight_34470a_digital_multimeter_7_5_digit_truevolt_dmm_benchtop_2f.jpg","attrs":{"Brand Name":"Keysight\/Agilent","Model Number":"34470A","Place of Origin":"Malaysia","Minimum Order Quantity":"1 set"}}
{"title":"Keysight N1914B EPM Series Dual-Channel Power Meter Seven Practices to Prevent","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/7a\/de\/9c7fefa4b7fbe066890917b13b25-200x200-1\/keysight_n1914b_epm_series_dual_channel_power_meter_seven_practices_to_prevent_damaging_power_meters_and_power_sensors.jpg","attrs":{"Brand Name":"Keysight","Model Number":"N1914B","Certification":"ISO17025","Place of Origin":"U.S.A"}}
{"title":"Tos9200 Kikusui Hipot Tester With Insulation Resistance Test Ac- 5.0 Kv","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/23\/c8\/37f6d0f47af61d5c37afa84c8c12-200x200-1\/tos9200_kikusui_hipot_tester_with_insulation_resistance_test_ac_5_0_kv.jpg","attrs":{"Brand Name":"Kikusui","Model Number":"TOS9200","Certification":"ce","Place of Origin":"Japan"}}
{"title":"34970A Data Acquisition \/ Data Logger Switch Unit Keysight Agilent","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/f0\/ab\/774799457b4b3fc54029fe592aec-200x200-1\/34970a_data_acquisition_2f_data_logger_switch_unit_keysight_agilent.jpg","attrs":{"Brand Name":"Keysight (Agilent)","Model Number":"34970A","Certification":"ce","Place of Origin":"Malaysia"}}
{"title":"Keysight Agilent L4445A Microwave Switch \/ Attenuator Driver Fast Delivery","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/a9\/cd\/f098642dd237f4b096ea403172a9-200x200-1\/keysight_agilent_l4445a_microwave_switch_2f_attenuator_driver_fast_delivery.jpg","attrs":{"Brand Name":"Keysight (Agilent)","Model Number":"L4445A","Certification":"ce","Place of Origin":"Malaysia"}}
{"title":"Chroma 19073 Hipot Tester Insulation Resistance Measurement From 1M To 50G","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/12\/75\/b548eea3ed06ec4ca04672b22664-200x200-1\/chroma_19073_hipot_tester_insulation_resistance_measurement_from_1m_to_50g.jpg","attrs":{"Brand Name":"Chroma","Model Number":"19073","Certification":"ce","Place of Origin":"TAIWAN"}}
{"title":"AWG7102 Tektronix Arbitrary Waveform Generator 10GS\/S High Bandwidth Output","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/a4\/59\/780cfffb4471816d6af253f93f99-200x200-1\/awg7102_tektronix_arbitrary_waveform_generator_10gs_2fs_high_bandwidth_output.jpg","attrs":{"Brand Name":"Tektronix","Model Number":"AWG7102","Certification":"ISO:17025 Accredited Calibration","Place of Origin":"USA"}}
Keysight Agilent34470A Digital Multimeter 7 ½ Digit Basic Truevolt
Description of Keysight Agilent 34470A Digital Multimeter
The Keysight 34470A 7½ digit, Performance Truevolt Digital Multimeters offer higher levels of accuracy, speed and resolution.
1. Specifications are for 90-minute warm-up, integration setting of 10 or 100 NPLC, auto-zero on, AC slow filter. ACAL run within the last 2 days.
2. 20% over range on all ranges, except 1000 DCV, 750 ACV, 10 DCA, 3 DCA, 10 ACA, 3 ACA, and diode test have 0%.
3. Relative to calibration standards.
4. The 10 A range is only available on a separate front panel connector. Add 2 mA base per amp for inputs greater than 5 Arms. 5. Add this for each °C outside TCAL ±5°C.
6. Add this for each °C outside the last TACAL ±2°C.
7. Add this for each °C outside TACAL ±2°C.
8. Specifications are for 4-wire ohms function or 2-wire ohms function using math null for offset. Without math null, add 0.2 Ω additional error in 2-wire ohms function. The 100 MΩ and 1 GΩ ranges are 2-wire only. See the manual for low power ohms specification and measurement currents.
9. For each additional volt over ±500 V add 0.02 mV of error.
10. Specifications are for the voltage measured at the input terminals. The 1 mA test current is typical. Variation in the current source will create some variation in the voltage drop across a diode junction.
11. See user manual for details.
12. Actual measurement range and probe errors will be limited by the selected probe. Probe accuracy adder includes all measurement and ITS-90 temperature conversion errors. PT100 Ro settable to 100Ω ± 5Ω to remove the initial probe error.
13. The internal reference junction uses the U1180A or equivalent adapter. This has a typical performance of ±1.0°C. This internal reference junction can be adjusted for better accuracy. An external reference junction can also be used.
14. Specifications are for sine wave input > 0.3% of range and > 1 mVrms. 750 ACV range limited to 8 x 107 V.Hz. For each additional volt over 300 Vrms add 1 mVrms of error.
15. Low-frequency performance: three filter settings are available: 3 Hz, 20 Hz, 200 Hz. Frequencies greater than these filter settings are specified with no additional errors.
16. Specifications are for sine wave input > 1% of range and > 10 µArms.
17. Specifications are for sine wave input unless stated otherwise.
18. Square wave input specified for 10 Hz to 300 kHz for 1 second aperture. For shorter apertures, the minimum frequency requires > 2 cycles.
19. Input > 100 mV. For 10 mV to 100 mV inputs, multiply % of reading error x10. Amplitude 10% to 120% of range except 14% to 100% for the 750 ACV range. Specifications are for 1-second gate time (7 digits).
20. Specifications are for using Math Null zeroing. High dissipation factor capacitors may show different results than a single frequency measurement. Film capacitors usually have lower dissipation factors than other dielectrics.
21. The second burden voltage can be obtained by using the 10 A input range.
22. Sample rate (actual): 50.118 kHz (Aperture = 19.953 µs). 23. Thermistor type: 2.2 kΩ (model number 44004), 5 kΩ (model number 44007) and 10 kΩ (model number 44006)
Highlights of Keysight Agilent 34470A
Histogram, bar and trend charts on 4.3-inch color graphical display ease monitoring and speed up statistical analysis.
Measure with confidence, with high basic DCV accuracy of 16 ppm.
Test low power devices with 1 µA range and pA resolution.
Flexibly automate measurements over USB or LAN/LXI core interface.
Digitizing and advanced triggering (DIG) now included.
Truevolt DMM's graphical capabilities such as trend and histogram charts offer more insights quickly. Both models also provide a data logging mode for easier trend analysis and a digitizing mode for capturing transients.
Measure low-power devices by 34470A:
The ability to measure very low current, 1 µA range with pA resolution, allows you to make measurements on very low power devices.
Maintain calibrated measurements by 34470A:
Auto calibration allows you to compensate for temperature drift so you can maintain measurement accuracy throughout your workday.
List of Options of Keysight 34470A
100
100-volt ac line selection
120
120-volt ac line selection
220
220-volt ac line selection
240
240-volt ac line selection
DIG
Digitizing and Advanced Triggering for 34470A Truevolt DMM license
GPB
GPIB interface module for Truevolt series DMMs
MEM
2M Memory for 34470A Truevolt DMM license
SEC
NISPOM and file security for Truevolt series DMMs license
Z540
ANSI/NCSL Z540.3-2006 Calibration
FAQ:
1.Can you ship order to Canada or Australia? Yes,we can .We send orders worldwide.
2. What delivery method do you use? and delivery time?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question?
You can contact us online or leave us messages below.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Distributor/Wholesaler
Year Established:
2003
Total Annual:
500000-1000000
Employee Number:
>100
Ecer Certification:
Verified Supplier
Meigaolan is a test and measurement solutions and production suppliers, founded in 2003 and located in Shenzhen,China.
Our highly skilled Sale Representatives can assist you with all of your
new and refurbished test equipment needs, providing EMC test solutions
and building your Anechoic ... Meigaolan is a test and measurement solutions and production suppliers, founded in 2003 and located in Shenzhen,China.
Our highly skilled Sale Representatives can assist you with all of your
new and refurbished test equipment needs, providing EMC test solutions
and building your Anechoic ...