China factories

China factory - Hebei Kaixiang Electrical Technology Co., Ltd

Hebei Kaixiang Electrical Technology Co., Ltd

  • China,Shijiazhuang ,Hebei
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China 1200 KW Resistive Load Bank Calculation Continuous Working For Generator
China 1200 KW Resistive Load Bank Calculation Continuous Working For Generator

  1. China 1200 KW Resistive Load Bank Calculation Continuous Working For Generator
  2. China 1200 KW Resistive Load Bank Calculation Continuous Working For Generator

1200 KW Resistive Load Bank Calculation Continuous Working For Generator

  1. MOQ: ONE SET
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, D/P, T/T, Western Union, MoneyGram, D/P
Supply Ability 20 SETS ONE MONTH
Delivery Time ONE MONTH AFTER GET DEPOSIT
Packaging Details WOODEN CASE
Rating Voltage 440VAC/50Hz, 3 phase 4 wire, line voltage 440V, phase voltage 254V
Rated Voltage 440 VAC
Installed Capacity Resistive load: 1200 kW
Control Power 690 VAC / 50 Hz
size 1600*2600*2000mm
weight 1700kg
Brand Name KAIXIANG
Model Number 1200KW
Certification ISO9001
Place of Origin HEBEI CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, D/P, T/T, Western Union, MoneyGram, D/P Supply Ability 20 SETS ONE MONTH
Delivery Time ONE MONTH AFTER GET DEPOSIT Packaging Details WOODEN CASE
Rating Voltage 440VAC/50Hz, 3 phase 4 wire, line voltage 440V, phase voltage 254V Rated Voltage 440 VAC
Installed Capacity Resistive load: 1200 kW Control Power 690 VAC / 50 Hz
size 1600*2600*2000mm weight 1700kg
Brand Name KAIXIANG Model Number 1200KW
Certification ISO9001 Place of Origin HEBEI CHINA
High Light resistive reactive load bankprogrammable load bank

For Diesel Generator Automatic Remote Control 440V 1200K Watt AC Load Bank
 
Product Description

 

AC440-1200kW Automatic Load Bank is mainly used to test the performance of generator. It can provide scientific monitor measure for generating set equipment.

 

Technical Parameters

 

Rating Voltage/Frequency 440VAC/50Hz, 3 phase 4 wire, line voltage 440V, phase voltage 254V
Rated Load Power Resistive load: 1200kW
Installed Capacity Resistive load: 1200kW
Load Step 1,2,2,5,10,10,20,50,100,200,200,200,200, 200kW, min step load: 1kW
PF(Power Factor) 1
Load Tolerance (each step) ±5%
Load Tolerance(overall) ±3%
Display Precision 0.5 class
Control Power 380VAC/50Hz 3 phase 4 wire (line voltage 380V, phase voltage 220V )
Wire Connection

Load power supply input——Copper bar (star coupling)

Control power supply input——Connector-bar

Insulation F
Protection Grade IP21
Way of Working Continuous Working
Casing Dimensions and Cooling about 1600*2600*2000mm (length*width*height) Forced air cooling,Horizontal inlet air,Vertical cooling
Weight About 1700kgs/set
Transportation Hoisting, there are lifting lug in top of casing
Casing Color Grey(RAL7035)
Ambient Temperature -10℃~+50℃
Relative Humidity ≤95%
Altitude ≤2500 meter
Atmospheric Pressure 86~106kPa
Contactor Schneider
Fuse DELIXI
MCU INFINEON
Data processing software Kaixiang(self-developed)
Alloy Resistance Kaixiang(self-developed)


Product Advantage
 

1. Real-time Monitor: through software display main parameter value, such as voltage, current, power, power factor, frequency and time.

2. Security monitoring and control: monitor working state of the load bank by watching software light, when abnormally stop and protect, it can show the reason.

3. Data Collection Interval: the minimum data resolving time is 2s.

4.Data save and query: all the test data is saved in the software, easy to query in the history testing data.

 

Application
 

1. for generator power ,the frequency,the voltage,the current,power factor and other generator parameters

2. Because Most of the generator use the diesel oil,which can cause the fuel oil unfilled,carbon deposition ,complete machine efficiency reduced when the diesel oil load is lower than 50% or in idling situation for a long time and even cause starting difficulty ,power insuffciency,oil consumption increased,finally,opening the cylinder for maintenance too early and the abandonment ,so the load bank will be generator's ideal false load.

 

 

 
 

 
 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company,Seller

  • Year Established:

    1994

  • Total Annual:

    10000000-15000000

  • Employee Number:

    120~130

  • Ecer Certification:

    Active Member

Kaixiang intelligent power detection technology is the Chinese industry leader dedicated to providing load testing and maintenance of all types of power, to avoid accidents and economic losses due to power failure. As a national high-tech enterprises, science and technology to create the industry... Kaixiang intelligent power detection technology is the Chinese industry leader dedicated to providing load testing and maintenance of all types of power, to avoid accidents and economic losses due to power failure. As a national high-tech enterprises, science and technology to create the industry...

+ Read More

Get in touch with us

  • Reach Us
  • Hebei Kaixiang Electrical Technology Co., Ltd
  • No33 Wangshan Road, Green Island Economic Development Zone, Shijiazhuang, China
  • https://www.resistive-loadbank.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement