China 24V 25Ah Medical Device Battery , Medical Cart Battery Deep Cycle
China 24V 25Ah Medical Device Battery , Medical Cart Battery Deep Cycle

  1. China 24V 25Ah Medical Device Battery , Medical Cart Battery Deep Cycle

24V 25Ah Medical Device Battery , Medical Cart Battery Deep Cycle

  1. MOQ: 100pcs
  2. Price: Negotiable
  3. Get Latest Price
Supply Ability 450Mwh/year
Delivery Time 2~4weeks for samples; 4~6weeks for mass production
Packaging Details standard export carton
Payment Terms L/C, T/T
Material Nano LiFePO4
Nominal voltage 25.6V
Nominal capacity 25Ah
Impedance ≤60mΩ
Dimension 196(±2)*165(±2)*174(±2)mm
Weight 6.8kg
Warranty 2 years
Max Charging Current 25A
Max Discharge Current 25A
Peak discharge Current 85A(3S)
Brand Name Topband
Model Number TB2425F-S110A
Certification MSDS, ISO9001, ISO14001
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 450Mwh/year Delivery Time 2~4weeks for samples; 4~6weeks for mass production
Packaging Details standard export carton Payment Terms L/C, T/T
Material Nano LiFePO4 Nominal voltage 25.6V
Nominal capacity 25Ah Impedance ≤60mΩ
Dimension 196(±2)*165(±2)*174(±2)mm Weight 6.8kg
Warranty 2 years Max Charging Current 25A
Max Discharge Current 25A Peak discharge Current 85A(3S)
Brand Name Topband Model Number TB2425F-S110A
Certification MSDS, ISO9001, ISO14001 Place of Origin China
High Light Medical Cart BatteryBattery For Medical Equipment

Quality Safety Medical Equipment Batteries 24V 40Ah LiFePO4 , Lithium Iron Phosphate

 

  • long life cycle( 2000cycles @ 100%DOD)
  • with built-in PCM/BMS protection
  • super quick charge/discharge performance
  • safe pressure valve design ( no explosion, no fire)
  • high energy density
  • low self-discharge( <3% per month)
  • 1/3 weight & 1/2 volume of lead acid battery
  • eco-friendly
  • high consistency
  • no memory effect
  • easily replace lead acid battery

 

 

1. Battery Pack Brief Introduction

 

This specification applies to the TB2425F-S110A battery manufactured by Shenzhen Topband Battery Co., Ltd, Describes the type and size, performance, technical characteristics, warning and caution of the rechargeable cell. Please be sure the voltage is equal or output voltage difference less than 0.2V before parallel connection, professionals only. It is strictly prohibited any series between battery packs. Any requirements on serials connection,please contact TOPBAND for details.

 

11 Battery Type

LiFePO4 (LFP)

12 Reference Standard

 

13 Product SPEC

24V/25Ah 8S1P

 

14 Cell Brand and Model

TB027070180C-Fe-25Ah

 

15 Period of Warranty

Period of Warranty reference to the contract

 

16 Battery Specification Amendment

If the raw materials, production processing, production system or battery usage environments & other conditions need to be change, the amendment side needs provide the written advice to the other side, only the both sides come to an end, the amendment will be effective.

 

2. Battery Pack Basic Features

NO. Items Characteristics Testing Methods
1 Nominal Voltage 25.6V Follow GB/T18287-2013>
2 Nominal Capacity 25Ah Follow
3 Minimum Capacity 23.75Ah Follow
4 Battery internal Impedance Internal Impedance≤60mΩ Internal Impedance Testing Machine(1kHz )
5 Shipment Voltage 25.627.2V Multi-meter
6 Dimension Length 196(±2)*165(±2)*174(±2)mm Vernier caliper
Width
Height
gross weight 6.8±0.2kg electronic scale
7 Working Temperature Charge 0~45℃, 45~85%RH Temperature & Humidity Instruments
Discharge -20~55℃, 45~85%RH
8 Storage Temperature & Humidity Range Short: above one month -20~+55℃,45~85%RH Temperature & Humidity Instruments
Medium: above three months 0~+45℃,45~85%RH
Long:above one year +5~+30℃,45~85%RH
9 Normal charge current 12A  
10 Fast charge current 25A  
11 Allowed maximum continuous discharge current 25A Pulse current 85A/3S
12 Allowed maximum reverse charge voltage Not Allowed /
13 Allowed maximum charge voltage 29.2±0.2V Multi-meter
14 Discharge cut-off voltage 16~20V Multi-meter
15 Pack series connection function None  

 

 

3. Battery Pack Electrical Characteristics

3.1 Testing Conditions (Unless Specially Requirements)

Temperature:20±5℃ Related Humidity: 45~75%

Atmosphere Pressure: 86~106kPa

The testing items under the Shipment Voltage(25.6V27.2V)

 

3.2 Battery Pack Electrical Characteristics

No. Items Standards Testing Methods
1

 

Internal Impedance

Impedance ≤60mΩ Under 20±5℃ Environment Temperature , the Usage Frequency of Fully Charge( 1KHz) , Use AC Internal Impedance test machine to test
2 Nominal Capacity 25Ah Rest for 0.5~1 hour after fully charge, Using electrical loader to connect with the battery output port, and discharge with constant current 0.2C till it can’t discharge. Do the cycle three times, if there is one time that the discharge time is equal or more than 285minute , you can stop.
3 Short circuit protection No load ability after short-circuit .comeback capability of loading after remove the lead away, Short the pack with the lead (<20mΩ). If remove the lead away, connect the electronic loader with P+, P- of protection board again, so load ability comes back.
4 Allowed Maximum continuous charge Current 25A charging with this current for more than 0.5h and the added temperature of battery pack less than 20℃.
5 Allowed Maximum continuous discharge Current 25A Discharging with this current for more than 0.5h and the added temperature of battery pack less than 20℃.
6 Over Current Protection 85~115A Using electron load connect with output side, discharge with 85A for about 3sec Discharge with 115A for less than 40 millisecond,
7 the delay time of over current protection 10~40ms Using electron load connect with output side, discharge with more than 115A and record the voltage wave of output side with oscillograph . Numerating the time of voltage from wave to zero for voltage.
8 cycle life Discharge Capacity ≥80% Discharge it with the current of 0.2C to the cut-off voltage, and store it for 15min.Charge a battery with the current of 0.2C, then keep the voltage and current constant and continue to charge it until completed . After storing the battery for 15min. The test is to be conducted as per the above cycles. The cycle should be 1000 times. At the 1001 times discharge capacity should not be less than ≥80% with 0.2C.
9 Discharge Temperature Characteristics The ratio between discharge capacity and charge capacity should be not less than the following value At 20±5℃ discharge the battery with the current of 0.2C to the cut-off voltage and record charge capacity. Store the battery at the following temperature for 2h and discharge the battery with 0.2C to the cut-off voltage.
Discharge Current Discharge Temperature
-20℃ 0℃ 25℃ 55℃
0.2C 60% 80% 100% 95%
10 Charge Retention remain capacity≥90%

 

At 20±5℃ completely charge and store it for 28days,and then discharge it with 0.2C to the cut-off voltage. (We suggest charge the battery to 25.6~27.2V every three months)

11 Over Discharge Protection furbish Charging With 0.2C Charge the battery with 0.2C for 5min and measure the output voltage (16V)of the battery pack. The battery should have load .

 

4. Battery Pack Reliability Test

4.1 Testing condition (Unless Special Requirements)

Temperature:20±5℃ Relative Humidity: 45~75%

Atmosphere Pressure: 86~106kPa

All testing under full capacity

 

4.2 Reliability Test

No. Items Standards Testing Methods
1 Vibration Testing The appearance of battery should not leakage, break or explosion Fix a charged battery on a vibrating table, vibrate it for 90 minutes in three mutually perpendicular directions at the 0.8mm resonance. The frequency is to be varied at the rate of 1hz/min between 10 and 55 hertz.
2 High Temperature Discharge Testing The battery should be no remarkable breakage, distortion. Discharge time should not less than 255mins Place a full charged battery under the environments of 55℃ for 2 hours. Discharge it at the current of 0.2C to the cut-off voltage. Then keep it at 20℃±5℃ for 2 hours.
3 Low Temperature Discharge Testing The battery should be no remarkable breakage, distortion. Discharge time should not less than 180 minute Place a full charged battery under the environments of -20℃ for 15-24 hours. Discharge it at the current of 0.2C to the cut-off voltage. Then keep it at 20℃±5℃ for 2 hours.
4 Constant Humidity & Temperature Testing The battery should be no remarkable breakage, distortion. Discharge time should not less than180mins Place a full charged battery under the environments of 40℃ and 90% - 95%RH for 48 hours. And keep it in the room temperature for 2 hours. Then discharge it at the current of 0.2C to the cut-off voltage.
5 High & Low Temperature Storage The battery should be no remarkable breakage, distortion. And charge/discharge normally Place a full charged battery in a oven with 55±2℃ for2 hours, then keep it under 20±5℃ for 4hrs, then place it in a oven with -20±2℃ for 2 hours, then keep for 4 hours under 20±5℃, cycle as high temperature-normal temperature-low temperature-normal temperature-high temperature for 10 times
 

5. BATTERY PACK SAFETY TEST

5.1 Testing condition (Unless Special Requirements)

Temperature:20±5℃ Relative Humidity: 45~75%

Atmosphere Pressure: 86~106kPa

All testing under full capacity

 

5.2 Battery Pack Safety Test

No. Items Standards Testing Methods
1 Short-Circuit No load ability after short-circuit .comeback capability of loading after remove the lead away, Short the pack with the lead (<20mΩ). If remove the lead away, connect the electronic loader with P+, P- of protection board again, so load ability comes back.
2 Over Discharge Protection Test The battery should be no remarkable breakage, distortion. Appearance and charge are normal. Discharge the battery at the rate of 0.2C with the load of 30Ω for 24h . Charging for 10sec with specified adapter , and check the voltage(16V)
3 Impact Test The battery should be no explosion or catch fire Place a full charged battery on a flat and put a stainless steel stick (Diamond 7.9mm) in the middle of the battery upright . Beat the steel stick with 9.1Kg

 

6. Pack diagram

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    1996

  • Total Annual:

    240million-250million

  • Employee Number:

    5000~5500

  • Ecer Certification:

    Active Member

Shenzhen Topband Co., Ltd. was registered in so-called “China Silicon Valley”, Shenzhen Hi-tech Industrial Park in 1996, and got listed in Shenzhen Stock Exchange ( the stock code as 002139) in 2007.   After years of rapid development, now Topband takes lithium battery as the ... Shenzhen Topband Co., Ltd. was registered in so-called “China Silicon Valley”, Shenzhen Hi-tech Industrial Park in 1996, and got listed in Shenzhen Stock Exchange ( the stock code as 002139) in 2007.   After years of rapid development, now Topband takes lithium battery as the ...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Topband Battery Co., Ltd
  • Topband Industry Park,Tangtou Town,Bao'an District,Sheznzhen,China
  • http://www.rechargeablelifepo4battery.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement