Payment Terms | L/C, T/T |
Supply Ability | 3Gwh/year |
Delivery Time | 4weeks for samples; 6~8weeks for mass production |
Packaging Details | standard export carton |
Material | LiFePO4 |
Nominal Voltage | 384V |
Normal Capacity | 50Ah |
Energy | 19.2KWh |
Internal resistance | ≤150mΩ |
Output voltage | 300-438V |
Standard charge current | 62.5A |
Standard discharge current | 50A |
Dimension | 600*600*1300mm |
Weight | 300Kg |
Cycles | ≥3500cycle (@DOD80% @0.33C) |
Communication | RS485-Modbus |
Brand Name | Topband |
Model Number | TB38450F-T112A |
Certification | UL, UN38.3, MSDS |
Place of Origin | China |
View Detail Information
Explore similar products
Long Life Time UPS Rechargeable Batteries 12V 125Ah Lithium Battery Pack
BMS 2.4kWh 1kHz 48V 50Ah 3U Ups Backup Battery TB4850F-T110
Pollution Free Lithium Iron Phosphate Battery 50ah , 24v Rechargeable Ups
200AH rechargeable lifepo4 battery , 24v deep cycle battery with Metal case
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 3Gwh/year |
Delivery Time | 4weeks for samples; 6~8weeks for mass production | Packaging Details | standard export carton |
Material | LiFePO4 | Nominal Voltage | 384V |
Normal Capacity | 50Ah | Energy | 19.2KWh |
Internal resistance | ≤150mΩ | Output voltage | 300-438V |
Standard charge current | 62.5A | Standard discharge current | 50A |
Dimension | 600*600*1300mm | Weight | 300Kg |
Cycles | ≥3500cycle (@DOD80% @0.33C) | Communication | RS485-Modbus |
Brand Name | Topband | Model Number | TB38450F-T112A |
Certification | UL, UN38.3, MSDS | Place of Origin | China |
High Light | Ups Replacement Batteries ,Ups Car Battery |
1. General Information
This specification defines the performance of rechargeable LiFePO4 battery pack TB38450F-T112A manufactured by SHENZHEN TOPBAND BATTERY CO.,LTD, describes the type, performance, technical characteristics, warning and caution of the battery pack. This system Include 4 pack modules, 1 control module, and 1 standard 19”cabinet.
2. Specification(@Battery initial Temp25±5℃)
NO. | Items | Criteria | Remarks | |
2.1 | Rated Capacity | 50Ah | ||
Minimum Capacity | 48Ah | |||
2.2 | Energy | 19.2KWh | ||
2.3 | Nominal Voltage | 384V | ||
2.4 | Outgoing Voltage | ≥384V | ||
2.5 | Internal resistance | ≤150mΩ | ||
2.6 | Communication | RS485-Modbus | ||
2.7 | Display | 3.5” TFT Screen | ||
2.8 | Limited charge voltage | 438±4V | ||
2.9 | Floating charge voltage | 414±4V | ||
2.10 | Maximum charge current | 62.5A | ||
2.11 | Maximum discharge current | 50A | ||
2.12 | Discharge cut-off voltage | 300V | ||
2.13 | Dimension | Single battery module or control module | Width: 482±3mm | |
Height: 176±3mm | ||||
Depth: 445±3mm | ||||
Cabinet | 600*600*1300mm | |||
2.14 | Net weight | Single module | Approx: 50kg | |
System | Approx: 300kg | |||
2.15 | Battery case / cabinet color | Black | ||
2.16 | Operating Temperature | Charging:0~50℃ | ||
Discharging:-20~60℃ | ||||
Recommended operating temperature:15℃~35℃ | ||||
2.17 | Self-discharge rate | Residual capacity:≤2%/month;≤12%/years | ||
2.18 | Storage Temperature & Humidity Range | Less than 1 month:-20℃~45℃,45%RH~80%RH | ||
Recommended storage environment: 15℃~35℃,45%RH~80%RH | ||||
Long time storage: If the battery need be stored for a long time, the voltage should be 396V(50%SOC), and stored in the condition as storage proposal. It need at least one charge & discharge cycle every six months |
3. Product Performance
Standard Test Conditions:
Unless otherwise specified, all performance tests is required conducted at temperature 25℃±2℃, Humidity less than 45%~75%RH.
Unless otherwise specified, the tested product is required unused within one month after outgoing.
NO. | Items | Criteria | Testing method | |
3.1 | Rated Capacity | 50Ah | @0.33C | |
3.2 | Internal resistance | ≤150mΩ | 50% battery SOC state frequency of 1 KHZ ac resistance tester | |
3.3 | Cycle life (@DOD80% @0.33C) | ≥3500cycle | ||
3.4 | Short circuit protection | 250A Fuse | ||
3.5 | Discharge Temperature Characteristics | -20℃ | ≥70% | At 25±5℃ discharge the battery with the current of 0.33C to the cut-off voltage and record charge capacity. Store the battery at various temperatures for 2h and discharge the battery with 0.33C to the cut-off voltage. |
-0℃ | ≥80% | |||
25℃ | ≥100% | |||
55℃ | ≥95% | |||
3.6 | Charge Retention ability | Residual capacity≥90% | Charge the battery to full capacity and store it for 28days, and then discharge it with 0.33C to the cut-off voltage. | |
Recovery capacity≥95% |
4. Protective circuit specification
The Battery Management System (BMS) can monitor and optimize every single prismatic cell during charge & discharge, to protect the battery pack overcharge, over discharge, short circuit. Overall, the BMS helps to ensure safe and accurate running.
NO. | Items | Content | Specification |
4.1 | Overcharge | Over-charge alarm for each cell | 3.55±0.030V |
Over-charge protection for each cell | 3.75±0.030V | ||
Over-charge release for each cell | 3.40±0.040V | ||
Over-charge alarm for total voltage | 426±4V | ||
Over-charge protection for total voltage | 450±4V | ||
Over-charge release for total voltage | 408±4V | ||
Over-charge release method | Under the release voltage | ||
4.2 | Over discharge | Over-discharge alarm for each cell | 2.80±0.040V |
Over-discharge protection for each cell | 2.50±0.040V | ||
Over-discharge release for each cell | 3.00±0.040V | ||
Over-discharge alarm for total voltage | 336±4V | ||
Over-discharge protection for total voltage | 300±4V | ||
Over-discharge release for total voltage | 360±4V | ||
Over-discharge release method | Charge to recovery | ||
4.3 | Over current | Charge over current alarm | 70±5A |
Charge over current protection | 80±5A | ||
Protection delay time | 3±1s | ||
Over current release method | Auto release after 1min | ||
Discharge over current alarm | 70±5A | ||
Discharge over current protection | 80±5A | ||
Protection delay time | 3±1s | ||
Over current release method | Auto release after 1min | ||
4.4 | Short circuit | Fuse protection, prohibit test | 250A Fuse |
4.5 | Battery temperature | Charge over temperature | Alarm @50±5℃ |
Protection @55±5℃ | |||
Release @50±5℃ | |||
Discharge over temperature | Alarm @60±5℃ | ||
Protection @65±5℃ | |||
Release @60±5℃ | |||
Charge low temperature | Alarm @0±5℃ | ||
Protection @-5±5℃ | |||
Release @0±5℃ | |||
Discharge low temperature | Alarm @-15±5℃ | ||
Protection @-20±5℃ | |||
Release @-15±5℃ |
5. Instructions
² Based on the character of cell, proper environment for transportation of LiFePO4 battery pack need to be created to protect the battery.
² Battery should stay in the warehouse 15℃~35℃ where it’s dry, clean, shade, and well-ventilated.
² The battery should be stored in 50% SOC during transportation.
² The battery needs to be charged every 6 months if out of use
² Keep the battery against dropping, turning over and serious stacking during loading.
² Ensure the single 96V50Ah battery module in the independent package and keep it face up.
Step1: Install single battery module to a standard 19” cabinet through 4 pcs M6 screws.
Note:Fix the battery module according to the module serial number. Install 1st module in the bottom, and the control module in the top.
Diagram 1 :Battery module view
Step2: Electrical connection
1st: Connect the CANBus between battery modules and control module;
2nd:Connect Battery power cable between modules as shown below;
3rd: Connect the Output power cable
4th: Connect the RS485 external communication port to UPS;
5th: Press on switch, and then can start the system output.
Note:When user needs to stop output and disconnect the system,reverse the above operation order.
Diagram 2 :System install schematic
6. Warning & Tips
² Please read and follow the specification and caution remarks on battery surface before use the battery. Improper use may cause heat, fire, rupture, damage or capacity deterioration of the battery. SHENZHEN TOPBAND BATTERY CO.,LTD. Describes is not responsible for any accidents caused by the usage without following our specification.
² The battery must be far away from heat source, high voltage, and avoid to be exposed in sunshine for a long time.
² Do not put the battery in a charger or equipment with wrong terminals connected.
² Never connect the positive and negative of battery with metal.
² Avoid excessive physical shock or vibration. don't hit, fall, stamp on the battery
² Without the permission of the manufacturer and guidance, forbidden to remove or to assemble the battery
² Do not use the battery mixed with other different manufacturers, type, or model batteries.
² Keep the battery against high temperature. Otherwise, it will cause battery heat, get into fire or lose some function and reduce the life.
² When battery run out of power, please charge your battery timely (≤15day).
² Please use the matched or suggested charger for this battery.
² If battery emits a peculiar smell, heating, distortion or appears any abnormity during working or storage, please stop using and take it out from the device.
² If the battery leaks and get into the eyes or skin, do not wipe, instead, rinse it with clean water and see doctor immediately.
² Please far away from children or pets.
² Do not put disuse battery into a fire or water.
7. Battery operation instruction
7.1 Do not surpass the largest charging current that the specification stipulated.
7.2 Do not surpass the highest limited voltage that the specification stipulated.
7.3 Charging temperature:within temperature scope that specification stipulated.
7.4 Charge with constant current, then with the constant voltage, no reverse charge, which is dangerous
7.5 Special note:
Short time doesn't affect the use of the battery overcharge too, but for a long period of time over discharge or over charge can affect the function of the battery failure, or the battery can't use permanent, appear serious safety hazards, need a long time floating please use the recommended floating model specification.
8. Other Chemical Reaction
Because batteries utilize a chemical reaction, battery performance will deteriorate over time even if stored for a long period of time without being used. In addition, if the various usage conditions such as charge, discharge, ambient temperature, etc. are not maintained within the specified ranges, the life expectancy of the battery may be shortened or the device in which the battery is used may be damaged by electrolyte leakage. If the discharge time is much shorter than the normal after fully charged, even battery is charged correctly, and this may indicate it is time to change the battery.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
1996
Total Annual:
240million-250million
Employee Number:
5000~5500
Ecer Certification:
Active Member
Shenzhen Topband Co., Ltd. was registered in so-called “China Silicon Valley”, Shenzhen Hi-tech Industrial Park in 1996, and got listed in Shenzhen Stock Exchange ( the stock code as 002139) in 2007. After years of rapid development, now Topband takes lithium battery as the ... Shenzhen Topband Co., Ltd. was registered in so-called “China Silicon Valley”, Shenzhen Hi-tech Industrial Park in 1996, and got listed in Shenzhen Stock Exchange ( the stock code as 002139) in 2007. After years of rapid development, now Topband takes lithium battery as the ...
Get in touch with us
Leave a Message, we will call you back quickly!