China factories

China factory - Yueqing Vorax Electric CO.,LTD

Yueqing Vorax Electric CO.,LTD

  • China ,Zhejiang
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China VRL22 Residual Current Operated Circuit Breaker With Overcurrent Protection RCBO
China VRL22 Residual Current Operated Circuit Breaker With Overcurrent Protection RCBO

  1. China VRL22 Residual Current Operated Circuit Breaker With Overcurrent Protection RCBO

VRL22 Residual Current Operated Circuit Breaker With Overcurrent Protection RCBO

  1. MOQ: 3000PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C, T/T
Poles number 1P+N, 3P+N
Type Type AC, Type A, Type ASi
Rated voltage AC240V, AC415V
Mechanical life 2000
Standard IEC/EN 61009-1
Rated frequency 50/60Hz
Rated current In 6A, 10A, 13A,16A, 20A, 25A, 32A, 40A, 50A, 63A
Brand Name HAROK
Model Number VRL22
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Poles number 1P+N, 3P+N
Type Type AC, Type A, Type ASi Rated voltage AC240V, AC415V
Mechanical life 2000 Standard IEC/EN 61009-1
Rated frequency 50/60Hz Rated current In 6A, 10A, 13A,16A, 20A, 25A, 32A, 40A, 50A, 63A
Brand Name HAROK Model Number VRL22
Place of Origin CHINA
High Light residual current breaker with overcurrent protection rcboAC415V Residual Current Operated Circuit BreakerAC415V a type rcbo

RCBO | Residual Current Circuit Breaker

with Overcurrent Protection

 

VRL22 Residual Current Operated Circuit Breaker with Overcurrent Protection (RCBO)

1. General

VRL22 residual current operated circuit breakers with overcurrent protection (RCBO) are suitable for lines with AC 50/60Hz, rated voltage 240V/415V, rated current up to 63A and for purposes of residual current protection, overload and short circuit protection. When any personal electric shock occurs or the circuit leakage current exceeds the predetermined value, the residual current operated circuit breaker can automatically cut off the power supply in a very short period of time, so that the safety of persons and electrical equipment can be operated. The residual current operated circuit breaker can be used for infrequent conversion of lines under normal conditions, and applied under occasions such as industrial, and commercial, high-rise buildings and residential houses.

 

2. Technical parameters

2.1 The tripping characteristic curves are as shown below.

 

2.2 Basic parameters

  Standard IEC/EN 61009-1
Main Specifications Model No. VRL22
Rated current In 6A, 10A, 13A,16A, 20A, 25A, 32A, 40A, 50A, 63A
Tripping Curve B: (3 ~ 5) In, C: (5 ~ 10) In
Poles 1P+N, 3P+N
Type (wave form of the earth leakage sensed) Type AC, Type A, Type ASi
Mechanical features Rated voltage Ue AC240V, AC415V
Frame size rated current In 63A
Rated residual operating current I△n 30mA, 100mA, 300mA, 500mA
Rated residual non-operating current I△no 15mA, 50mA, 150mA, 250mA
Rated short-circuit breaking capacity Icn 6000A, 10000A

Rated residual making and

breaking capacity I△m

3000A
Electrical life 2,000
Mechanical life 2,000
Rated impulse withstand voltage Uimp 4000V
Connection From top and bottom

 

2.3 The residual current breaking times

In (A) I△n (A) Breaking time when the residual current assumes the following values (s)
I△n 2I△n 5I△n 5A, 10A, 20A, 50A, 100A, 200A, 500A(a) I△t(b)
6~63 0.01, 0.03, 0.1, 0.3, 0.5 0.1 0.05 0.04 0.04 0.04

a. For tests of 5A, 10A, 20A, 50A, 100A, 200A and 500A, the current values beyond the lower limit of over-current instantaneous tripping are not tested.

B. Tests are done when I△t is equal to the lower limit current of over-current instantaneous tripping of type B and type C.

 

2.4 The over-current protection characteristics

No. Rated current In (A) Initial state Test current (A) Specified time (t) Expected result Remarks
a 6 ~ 63 Cold state 1.13 In t ≥ 1h Non-tripping  
b Immediately after sequence a 1.45 In t < 1h Tripping Increase to the specified current within 5s after test item a.
c Cold state 2.55 In 1s < t < 60s Tripping  
d Cold state 3 In t ≥ 0.1s Non-tripping Curve B
5 In t < 0.1s Tripping
5 In t ≥ 0.1s Non-tripping Curve C
10 In t < 0.1s Tripping

 

 

Product Description:

RCBO Type A is a Residual Current Operated Circuit Breaker with over-current protection. It is designed to provide protection against electric shock from leakage currents and over-current protection. It has a frame size rated current of 50A and a rated voltage of AC240V. It also has a mechanical life of 2000 and an electrical life of 2000. Its rated short-circuit breaking capacity is 230/240V 6000A, 10000A; 120V 15000A. RCBO Type A is a reliable and efficient circuit breaker that provides superior protection of electrical equipment.

 

Features:

  • Product Name: RCBO Type A
  • Connection: From Top To Bottom; From Bottom To Top
  • Classified by Type of Instantaneous Tripping: Type B: (3 ~ 5) In, Type C: (5 ~ 10) In
  • Rated Frequency: 50/60Hz
  • Rated impulse withstand voltage Uimp: 6000V
  • Rated short-circuit breaking capacity Icn: 230/240V 6000A, 10000A; 120V 15000A
 

Applications:

HAROK RCBO Type A circuit breaker is the perfect solution for commercial and industrial applications. It is equipped with VRL22, VAL003, VKL003, VDL006, VRL11, VRL01, VRL02, VRL03, VK007LE and other models with rated impulse withstand voltage Uimp of 6000V and rated short-circuit breaking capacity Icn of 230/240V 6000A, 10000A; 120V 15000A. This RCBO also features rated residual current operating time of ≤0.1s and rated residual current off-state of ≤0.1mA. The RCBO Type A provides an efficient and reliable circuit protection and is the ideal choice for safe and secure power distribution.

 

Technical Parameters:

Parameter Value
Product Name RCBO Type A
Rated Voltage Ue AC240V
Rated Residual Current Operating Time ≤0.1s
Rated Residual Current On-state ≤0.2mA
Classified by Type of Instantaneous Tripping Type B: (3 ~ 5) In, Type C: (5 ~ 10) In
Rated residual operating current I△n 0.01A, 0.03A, 0.1A, 0.3A
Frame size rated current Inm 50A
Rated Breaking Capacity 6kA
Mechanical life 2000
Electrical life 2000
 

Customization:

Custom RCBO Type A from HAROK

HAROK provides a wide range of custom Residual Current Operated Circuit Breaker with over-current protection, RCBO Type A. The product features model numbers: VRL22, VAL003, VKL003, VDL006, VRL11, VRL01, VRL02, VRL03, VK007LE. It is designed and manufactured in China and it has a rated impulse withstand voltage Uimp of 6000V. Depending on your needs, you can choose from a variety of rated residual non-operating current I△no, from 0.005A, 0.015A, 0.05A, 0.15A. It can be connected from top to bottom or from bottom to top. The rated residual current operating time is ≤0.1s and the rated current is 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A.

 

Packing and Shipping:

Packaging and Shipping for RCBO Type A:

  • The RCBO Type A product will be packed in a cardboard box.
  • The box will be sealed with adhesive tape and labeled with the product name and model number.
  • The box will then be placed in a shipping container for protection.
  • The shipping container will be labeled with the product name and model number.
  • The product will be shipped via an express courier service.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2003

  • Employee Number:

    >100

  • Ecer Certification:

    Verified Supplier

  YUEQING VORAX ELECTRIC CO., LTD (hereinafter referred to as "VORAX"), founded in 2003, has established itself as a prominent player in the low voltage electrics industry in China. With a prime location in Liushi Town, Yueqing city, Zhejiang Province, VORAX benefits from being s...   YUEQING VORAX ELECTRIC CO., LTD (hereinafter referred to as "VORAX"), founded in 2003, has established itself as a prominent player in the low voltage electrics industry in China. With a prime location in Liushi Town, Yueqing city, Zhejiang Province, VORAX benefits from being s...

+ Read More

Get in touch with us

  • Reach Us
  • Yueqing Vorax Electric CO.,LTD
  • Liuhuang Road, Liushi Town, Yueqing City, Zhejiang Province
  • https://www.rccbbreaker.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement