China VRL11 1P+N Residual Current Operated Circuit Breaker With Over-Current
China VRL11 1P+N Residual Current Operated Circuit Breaker With Over-Current

  1. China VRL11 1P+N Residual Current Operated Circuit Breaker With Over-Current
  2. China VRL11 1P+N Residual Current Operated Circuit Breaker With Over-Current
  3. China VRL11 1P+N Residual Current Operated Circuit Breaker With Over-Current
  4. China VRL11 1P+N Residual Current Operated Circuit Breaker With Over-Current
  5. China VRL11 1P+N Residual Current Operated Circuit Breaker With Over-Current
  6. China VRL11 1P+N Residual Current Operated Circuit Breaker With Over-Current

VRL11 1P+N Residual Current Operated Circuit Breaker With Over-Current

  1. MOQ: 3000PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C, T/T
Poles number 1P+N
Rated voltage 240V~(230V~), 120V~
Mechanical life 2000
Standard IEC/EN 61009-1
Rated frequency 50/60Hz
Rated Current 6A, 10A, 16A, 20A, 25A, 32A, 40A
Electrical life 2000
CURVE TYPE A, AC
Brand Name HAROK
Model Number VRL11
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Poles number 1P+N
Rated voltage 240V~(230V~), 120V~ Mechanical life 2000
Standard IEC/EN 61009-1 Rated frequency 50/60Hz
Rated Current 6A, 10A, 16A, 20A, 25A, 32A, 40A Electrical life 2000
CURVE TYPE A, AC Brand Name HAROK
Model Number VRL11 Place of Origin CHINA
High Light 40a type a rcbo40 amp type a rcbo5A Residual Current Operated Circuit Breaker

RCBO | Residual Current Operated Circuit Breaker with over-current protection

 

 

VRL11 Residual Current Operated Circuit Breaker with over-current protection (RCBO)

(MCB sized 1 module with switched neutral)

 

1. General

 

VRL11 residual current operated circuit breakers are suitable for lines with AC 50/60Hz, rated voltage 240V, 120V, rated current up to 40A and for purposes of residual current protection, overload and short circuit protection. When any personal electric shock occurs or the circuit leakage current exceeds the predetermined value, the residual current operated circuit breaker can automatically cut off the power supply in a very short period of time, so that the safety of persons and electrical equipment can be operated. The residual current operated circuit breaker can be used for infrequent conversion of lines under normal conditions, and applied under occasions such as industrial, and commercial, high-rise buildings and residential houses.

 

2. Technical parameters

 

2.1 The tripping characteristic curves are as shown below. 

 

2.2 Basic parameters

 

  Standard IEC/EN 61009-1
Main Specifications Model No. VDL006
Rated current In

5A, 6A, 10A, 13A, 15A, 16A, 20A, 25A, 30A, 32A, 35A, 40A

Classified by Type of Instantaneous Tripping Type B: (3 ~ 5) In, Type C: (5 ~ 10) In
Poles 1P + N
Type (wave form of the earth leakage sensed) Type B
Mechanical features Rated voltage Ue AC240V
Frame size rated current In 40A
Rated residual operating current I△n 0.006A, 0.01A, 0.03A, 0.1A, 0.3A
Rated residual non-operating current I△no

0.003A, 0.005A, 0.015A, 0.05A, 0.15A

Rated short-circuit breaking capacity Icn

10000A (230, 240V~); 15000A(120V~)

Rated residual making and

breaking capacity I△m

3000A
Electrical life 2,000
Mechanical life 2,000
Rated impulse withstand voltage Uimp 6000V
Connection From top and bottom, from bottom and top

 

 

2.3 The residual current breaking times

 

In (A) I△n (A) Breaking time when the residual current assumes the following values (s)
I△n 2I△n 5I△n 5A, 10A, 20A, 50A, 100A, 200A, 500A(a) I△t(b)
5~40 0.006, 0.01, 0.03, 0.1, 0.3 0.1 0.05 0.04 0.04 0.04

a. For tests of 5A, 10A, 20A, 50A, 100A, 200A and 500A, the current values beyond the lower limit of over-current instantaneous tripping are not tested.

B. Tests are done when I△t is equal to the lower limit current of over-current instantaneous tripping of type B and type C.

 

 

2.4 The over-current protection characteristics

 

No. Rated current In (A) Initial state Test current (A) Specified time (t) Expected result Remarks
a 6 ~ 40 Cold state 1.13 In t ≥ 1h Non-tripping  
b Immediately after sequence a 1.45 In t < 1h Tripping Increase to the specified current within 5s after test item a.
c Cold state 2.55 In 1s < t < 60s Tripping  
d Cold state 3 In t ≥ 0.1s Non-tripping Type B
5 In t < 0.1s Tripping
5 In t ≥ 0.1s Non-tripping Type C
10 In t < 0.1s Tripping

 

 

 

3. Outline and installation dimensions (mm)

 

 

 

 

Product Description:

RCBO Type A is a Residual Current Operated Circuit Breaker with over-current protection, which can provide protection against electric shock and short-circuit current. It features a Rated Residual Current Operating Time of ≤0.1s, a Rated Frequency of 50/60 Hz, and a Frame size with a Rated current Inm of 50A. It also has a Rated residual operating current I△n of 0.01A, 0.03A, 0.1A, 0.3A, and a Rated Current of 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A.

RCBO Type A is safety device designed to protect people and electrical equipment from the risk of electric shock and short-circuit current, as well as providing over-current protection. With a fast-acting Residual Current Operating Time of ≤0.1s and a wide range of Rated Current, it is suitable for a variety of applications. Its robust Frame size and Rated Frequency of 50/60 Hz makes it a reliable and durable choice for many industries.

RCBO Type A is an essential safety device for any electrical installation, and is an ideal choice for providing reliable over-current protection and residual current operated circuit breaker. Its wide range of Rated Current and Rated residual operating current I△n options make it suitable for various applications, while its Rated Frequency of 50/60 Hz and Rated Residual Current Operating Time of ≤0.1s make it a reliable and durable choice.

 

Features:

  • Product Name: RCBO Type A
  • Rated Current: 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A
  • Rated impulse withstand voltage Uimp: 6000V
  • Rated Residual Current On-state: ≤0.2mA
  • Rated Residual Current Operating Time: ≤0.1s
  • Classified by Type of Instantaneous Tripping: Type B: (3 ~ 5) In, Type C: (5 ~ 10) In
  • Residual Current Operated Circuit Breaker with Over-current Protection

 

Applications:

HAROK's RCBO type A is an ideal choice for efficient and reliable over-current protection. It is designed to detect and disconnect circuits when an abnormal current is detected. Its rated residual current operating time is ≤0.1s and rated current is 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A. It is available in several different models including VRL22, VAL003, VKL003, VDL006, VRL11, VRL01, VRL02, VRL03, VK007LE. It offers two types of connection: from top to bottom; from bottom to top. Rated residual current on-state is ≤0.2mA and electrical life is 2000. It is made of high quality materials that ensure superior performance and durability. This product is manufactured in CHINA and offers the highest level of safety and reliability.

 

Technical Parameters:

Parameter Value
Product Name Residual Current Operated Circuit Breaker with over-current protection, RCBO TYPE A, RCBO CIRCUIT BREAKER
Mechanical life 2000
Rated Breaking Capacity 6kA
Electrical life 2000
Rated Frequency 50/60Hz
Rated short-circuit breaking capacity Icn 230/240V 6000A, 10000A; 120V 15000A
Rated residual non-operating current I△no 0.005A, 0.015A, 0.05A, 0.15A
Rated Residual Current On-state ≤0.2mA
Rated residual operating current I△n 0.01A, 0.03A, 0.1A, 0.3A
Classified by Type of Instantaneous Tripping Type B: (3 ~ 5) In, Type C: (5 ~ 10) In
Rated Residual Current Off-state ≤0.1mA

 

Customization:

Custom RCBO Type A from HAROK

Specifications:

  • Brand Name: HAROK
  • Model Number: VRL22, VAL003, VKL003, VDL006, VRL11, VRL01, VRL02, VRL03, VK007LE
  • Place of Origin: CHINA
  • Mechanical life: 2000
  • Electrical life: 2000
  • Rated Frequency: 50/60Hz
  • Connection: From Top To Bottom; From Bottom To Top
  • Product Name: RCBO Type A

Residual Current Operated Circuit Breaker with over-current protection, HAROK’s RCBO Type A is a reliable and durable device to protect electrical circuits from overloads and short circuits. It is designed with a mechanical life of 2000 and electrical life of 2000, rated frequency of 50/60Hz, and connection from top to bottom and from bottom to top.

 

Packing and Shipping:

RCBO Type A Packaging and Shipping:

  • The product is packaged in a cardboard box.
  • The product is placed in a sealed plastic bag.
  • The box is labeled with product name, model number, date of manufacture, and other pertinent information.
  • The box is then placed in a shipping container.
  • The shipping container is labeled with the recipient's address and other shipping information.
  • The container is then shipped to the destination.

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2003

  • Employee Number:

    >100

  • Ecer Certification:

    Verified Supplier

  YUEQING VORAX ELECTRIC CO., LTD (hereinafter referred to as "VORAX"), founded in 2003, has established itself as a prominent player in the low voltage electrics industry in China. With a prime location in Liushi Town, Yueqing city, Zhejiang Province, VORAX benefits from being s...   YUEQING VORAX ELECTRIC CO., LTD (hereinafter referred to as "VORAX"), founded in 2003, has established itself as a prominent player in the low voltage electrics industry in China. With a prime location in Liushi Town, Yueqing city, Zhejiang Province, VORAX benefits from being s...

+ Read More

Get in touch with us

  • Reach Us
  • Yueqing Vorax Electric CO.,LTD
  • Liuhuang Road, Liushi Town, Yueqing City, Zhejiang Province
  • https://www.rccbbreaker.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement