Payment Terms | L/C, T/T, Western Union, MoneyGram |
Product Name | Residual Current Circuit Breaker |
Model | VML01 |
Rated current | 16A, 25A, 32A, 40A, 63A, 80A, 100A |
Rated voltage | 2P: 240V 4P: 415V |
Rated frequency | 50/60 Hz |
Terminal connection type | Cable/Pin-type busbar |
Brand Name | HAROK |
Model Number | VML01 |
Place of Origin | CHINA |
View Detail Information
Explore similar products
240/415VAC Residual Current Circuit Breakers RCCB Type AC NF SEMKO VDE KEMA
UKCA 30mA-300mA Residual Current Circuit Breaker RCCB Type EV 10kA
50/60Hz 2P 4P Electrical Residual Current Circuit Breaker RCCB For Water Heater
16A 25A 2pole RCCB TYPE G Short Time Delay VKL11 For EV Charging Systems
Product Specification
Payment Terms | L/C, T/T, Western Union, MoneyGram | Product Name | Residual Current Circuit Breaker |
Model | VML01 | Rated current | 16A, 25A, 32A, 40A, 63A, 80A, 100A |
Rated voltage | 2P: 240V 4P: 415V | Rated frequency | 50/60 Hz |
Terminal connection type | Cable/Pin-type busbar | Brand Name | HAROK |
Model Number | VML01 | Place of Origin | CHINA |
High Light | HAROK 40a 100ma RCCB ,40a 100ma INMETRO RCCB ,Housing 40a 100ma RCCB |
HAROK 50/60 Hz 40a 100ma RCCB Inmetro 240V 415V rccb in electrical
VML01 Residual Current Circuit Breaker RCCB Inmetro
1. General
1.1 Function
Control electric circuits.
Protect people against indirect contacts and additional protection against direct contacts.
Protect installations against fire hazard due to insulation faults.
Residual current circuit breakers are used in housing, tertiary sector and industry.
1.2 Selection
Detectable wave form
AC class
Tripping is ensured for slowly increasing sinusoidal AC residual currents
A class
Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.
ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)
Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.
Note: Our ASi type includes G/KV function and Si function.
1.3 Approvals and certificates
We certify that the RCCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying
with the requirements.
1. Verification of the operating characteristic as per Seq. - D0 CL9.9
2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16
3. High Voltage Test as per D.3 of Annex D
4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)
Tripping sensitivity
10mA - precision instrument leakage protection and bathroom use.
30mA - additional protection against direct contact.
100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;
300mA/500mA - protection against indirect contacts, as well as fire hazard.
Tripping time
Instantaneous
It ensures instantaneous tripping(without time-delay).
Short time delay ASi
(High Immunity/ Avoid nuisance tripping &blinding)
It ensures any tripping at least 10ms.
Selective
It ensures total discrimination with a non selective RCD placed downstream.
RCCB | Residual Current Circuit Breaker
2. Technical parameters
Standard | IEC/EN 61008-1 AS/NZS61008.1 | |
Electrical features | Model No. | VML01 |
Poles | 2P, 4P | |
Rated current In | 16A, 25A, 32A, 40A, 63A, 80A, 100A | |
Rated Sensitivity I△n | 10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA | |
Rated voltage Ue | 2P: 240V 4P: 415V | |
Insulation voltage Ui | 415V | |
Rated frequency | 50/60 Hz | |
Rated residual making and breaking capacity I△m | 1500A | |
Short-circuit current Inc=I△c | 6000A, 10000A | |
Type (wave form of the earth leakage sensed) | AC, A, ASi, S | |
break time under I△n | ≤0.1s(Normal type), 10ms~300ms(ASi type). 150ms~500ms(S type) | |
Rated impulse withstand voltage(1.2/50) Uimp | 4kV | |
Dielectric test voltage at ind. Freq. for 1 min | 2.5 | |
Pollution degree | 2 | |
Mechanical features | Electrical life | ≥2000 |
Mechanical life | ≥2000 | |
Fault current indicator | Yes | |
Terminal protection degree | IP20 | |
Ambient temperature (with daily average≤35℃) | -25℃ to 50℃ | |
Storage temperate | -30℃ to 70℃ | |
Installation | Terminal connection type | Cable/Pin-type busbar |
Terminal size top/bottom for cable | 25-35 mm² | |
18-3/18-2 AWG | ||
Terminal size top/bottom for busbar | 10/16 mm² | |
18-8/18-5 AWG | ||
Tightening torque | 2.5 N·m | |
22 In-Ibs. | ||
Mounting | On DIN rail EN 60715 (35mm) by means of fast clip device | |
Connection | From top and bottom |
3. RCCB Outline and installation dimensions (mm)
Company Details
Business Type:
Manufacturer
Year Established:
2003
Employee Number:
>100
Ecer Certification:
Verified Supplier
YUEQING VORAX ELECTRIC CO., LTD (hereinafter referred to as "VORAX"), founded in 2003, has established itself as a prominent player in the low voltage electrics industry in China. With a prime location in Liushi Town, Yueqing city, Zhejiang Province, VORAX benefits from being s... YUEQING VORAX ELECTRIC CO., LTD (hereinafter referred to as "VORAX"), founded in 2003, has established itself as a prominent player in the low voltage electrics industry in China. With a prime location in Liushi Town, Yueqing city, Zhejiang Province, VORAX benefits from being s...
Get in touch with us
Leave a Message, we will call you back quickly!