Payment Terms | L/C, T/T, Western Union, MoneyGram |
Product Name | Miniature Circuit Breaker |
Pole | 1P, 1P+N, 2P, 3P, 3P+N, 4P |
Rated current In | 1A, 2A, 3A, 4A, 6A, 10A, 15A, 16A, 20A, 25A, 30A, 32A, 40A, 45A, 50A, 60A, 63A |
Rated voltage Ue | 120V, 230/400V ~ 240/415V |
Electrical life | 10,000 Times |
Mechanical life | 20,000 Times |
Rated breaking capacity | 4500A, 6000A, 10000A |
Brand Name | HAROK |
Model Number | VF008 |
Place of Origin | CHINA |
View Detail Information
Explore similar products
High-Quality 500,000 Cycles Main Switch Isolator 4 Poles 100A
VIS100 4P 100A Main Switch Isolating Circuit Breaker Household Function
HAROK 63 Amp 2 Pole Isolator Switch White Body With Red Knob Din Rail Products
VIS100 DC Miniature Circuit Breaker 2 Pole 63 Amp Isolator For Solar PV System
Product Specification
Payment Terms | L/C, T/T, Western Union, MoneyGram | Product Name | Miniature Circuit Breaker |
Pole | 1P, 1P+N, 2P, 3P, 3P+N, 4P | Rated current In | 1A, 2A, 3A, 4A, 6A, 10A, 15A, 16A, 20A, 25A, 30A, 32A, 40A, 45A, 50A, 60A, 63A |
Rated voltage Ue | 120V, 230/400V ~ 240/415V | Electrical life | 10,000 Times |
Mechanical life | 20,000 Times | Rated breaking capacity | 4500A, 6000A, 10000A |
Brand Name | HAROK | Model Number | VF008 |
Place of Origin | CHINA | ||
High Light | UL489 Circuit Breaker IP20 ,IP20 Miniature Circuit Breaker ,mini mcb 32 amp |
VF008 Miniature Circuit Breaker
1. General
1.1 Function
-protection of circuits against short-circuit currents
-protection of circuits against overload currents, switch
-isolation
VF008circuit-breakers are used in domestic installation, as well as in commercial and industry electrical distribution systems.
1.2 Selection
Technical data of the network at the point considered:
-short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device
-Network normal voltag
Tripping curves:
B curve (3-5In)
protection for people and big length cables in TN and IT systems.
C curves (5-10In)
protection for resistive and inductive loads with low inrush current.
D curves (10-14In)
protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers,
breakdown lamps)
2. Technical parameters
2.1
Standard | IEC/EN 60947-2 | IEC/EN 60947-2 | |||
Electrical features | Model No. | VF008 | |||
Poles | 1P, 1P+N, 2P, 3P, 3P+N, 4P | 1P, 2P, 3P, 4P | |||
Rated current In | 1A, 2A, 3A, 4A, 6A, 10A, 15A, 16A, 20A, | ||||
25A, 30A, 32A, 40A, 45A, 50A, 60A, 63A | |||||
Rated voltage Ue | 120V, 230/400V ~ 240/415V | ||||
Insulation voltage Ui | 500V | ||||
Rated frequency | 50/60 Hz | ||||
Rated breaking capacity | 4500A, 6000A, 10000A | ||||
Energy limiting class | 3 | ||||
Rated impulse withstand voltage(1.2/50) Uimp | 4000V | ||||
Dielectric test voltage at ind. Freq. for 1 min | 2kV | 1.89kV | |||
Pollution degree | 2 | ||||
Thermo-magnetic release characteristic | B, C, D | (8 – 12) In | |||
Mechanical features | Electrical life | 10,000 | |||
Mechanical life | 20,000 | ||||
Contact position indicator | Yes | ||||
Protection degree | IP20 | ||||
Reference temperature for setting of thermal element | 30℃ | ||||
Ambient temperature (with daily average≤35℃) | -5℃ to 40℃ | ||||
Storage temperature | -25℃ to 70℃ |
Installation | Terminal connection type | Cable/Pin-type busbar |
Terminal size top/bottom for cable | 25mm² | |
18-4AWG | ||
Terminal size top/bottom for busbar | 10mm² | |
18-8 AWG | ||
Tightening torque | 2.5 N·m | |
22In-Ibs. | ||
Mounting | On DIN rail EN 60715 (35mm) by means of fast clip device | |
Connection | From top and bottom | |
Combination with accessories | Auxiliary contact | Yes |
Shunt release | Yes | |
Under voltage release | Yes | |
Alarm contact | Yes |
2.2 Curves
3. Outline and installation dimensions (mm)
The UL489 Circuit Breaker is a mini circuit breaker that provides overload and short-circuit protection for electrical systems. It is designed to be reliable and safe to use in any installation. The UL489 Circuit Breaker has a rated current range of 1A, 2A, 3A, 4A, 6A, 10A, 15A, 16A, 20A, 25A, 30A, 32A, 40A, 45A, 50A, 60A, 63A and an insulation voltage Ui of 500V. It also features a wide storage temperature range of -25℃ to 70℃, with a reference temperature for setting of its thermal element at 30℃. Its robust design ensures it is reliable and safe to use in any installation. The UL489 Circuit Breaker is an ideal solution for providing overload and short-circuit protection for electrical systems.
HAROK UL489 Circuit breaker series is designed for providing electrical protection that satisfies the requirement of UL489 standard. This series of Mini Circuit Breakers (MCBs) is developed and produced by HAROK in CHINA. It has wide usage range from -5℃ to 40℃, and is certified by CE, SAA, SEMKO and NF. The reference temperature for setting of thermal element is 30℃. The rated voltage Ue is 120V, 230/400V~240/415V. Its mechanical life is up to 20,000. The model numbers include VF001, VF002, VF003, VK007, VA007, VF008, and VK009.
Parameters | Value |
---|---|
Storage Temperature | -25℃ To 70℃ |
Insulation Voltage Ui | 500V |
Thermo-magnetic Release Characteristic | B, C, D |
Operating Temperature | -5℃ To 40℃ |
Electrical Life | 10,000 |
Certificate | CE, SAA, SEMKO, NF |
Number of Poles | 1P, 1P+N, 2P, 3P, 3P+N, 4P |
Reference Temperature for Setting of Thermal Element | 30℃ |
Protection Type | Overload And Short-Circuit |
Protection Degree | IP20 |
We specialize in providing custom UL489 Circuit Breaker from HAROK.
Our model numbers include VF001, VF002, VF003, VK007, VA007, VF008, VK009.
Our UL489 Circuit Breaker are made in China with a reference temperature for setting of thermal element of 30℃, and rated voltage Ue of 120V, 230/400V ~ 240/415V.
The frequency rating is 50/60 Hz and it meets IEC/EN 60947-2 standards.
The Electrical life of our UL489 Circuit Breaker is 10,000.
Packaging and Shipping of UL489 Circuit Breaker:
Company Details
Business Type:
Manufacturer
Year Established:
2003
Employee Number:
>100
Ecer Certification:
Verified Supplier
YUEQING VORAX ELECTRIC CO., LTD (hereinafter referred to as "VORAX"), founded in 2003, has established itself as a prominent player in the low voltage electrics industry in China. With a prime location in Liushi Town, Yueqing city, Zhejiang Province, VORAX benefits from being s... YUEQING VORAX ELECTRIC CO., LTD (hereinafter referred to as "VORAX"), founded in 2003, has established itself as a prominent player in the low voltage electrics industry in China. With a prime location in Liushi Town, Yueqing city, Zhejiang Province, VORAX benefits from being s...
Get in touch with us
Leave a Message, we will call you back quickly!