VKL003 Mini RCBO Residual Current Operated Circuit Breaker With Over Current

  1. MOQ: 3000PCS
  2. Price:
  3. Get Latest Price
Payment Terms L/C, T/T
Poles number 1P+N
Type Type B
Rated current up to 40A
Product name mini rcbo
Rated voltage 240V, 120V
Mechanical life 2000
Brand Name HAROK
Model Number VKL003
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Poles number 1P+N
Type Type B Rated current up to 40A
Product name mini rcbo Rated voltage 240V, 120V
Mechanical life 2000 Brand Name HAROK
Model Number VKL003 Place of Origin CHINA
High Light RCBO Residual Current Operated Circuit BreakerMini Residual Current Operated Circuit BreakerAC240V Mini RCBO

 

MINI RCBO | Residual Current Operated Circuit Breaker with over-current protection

 

VKL003 Residual Current Operated Circuit Breaker with over-current protection

(MCB sized 1 module with switched neutral)

 

1. General

VKL003 residual current operated circuit breakers are suitable for lines with AC 50/60Hz, rated voltage 240V, 120V, rated current up to 40A and for purposes of residual current protection, overload and short circuit protection. When any personal electric shock occurs or the circuit leakage current exceeds the predetermined value, the residual current operated circuit breaker can automatically cut off the power supply in a very short period of time, so that the safety of persons and electrical equipment can be operated. The residual current operated circuit breaker can be used for infrequent conversion of lines under normal conditions, and applied under occasions such as industrial, and commercial, high-rise buildings and residential houses.

 

 

2. Technical parameters

2.1 The tripping characteristic curves are as shown below. 

 

 

2.2 Basic parameters

  Standard IEC/EN 61009-1
Main Specifications Model No. VKL003
Rated current In 5A, 6A, 10A, 13A, 15A, 16A, 20A, 25A, 30A, 32A, 35A, 40A
Classified by Type of Instantaneous Tripping Type B: (3 ~ 5) In, Type C: (5 ~ 10) In
Poles 1P + N
Type (wave form of the earth leakage sensed) Type AC, Type A
Mechanical features Rated voltage Ue AC240V, AC120V
Frame size rated current In 40A
Rated residual operating current I△n 6mA, 10mA, 30mA, 100mA, 300mA
Rated residual non-operating current I△no 3mA, 5mA, 15mA, 50mA, 150mA
Rated short-circuit breaking capacity Icn 240V: 4500A, 6000A, 10000A 120V: 15000A

Rated residual making and

breaking capacity I△m

500A
Electrical life 2,000
Mechanical life 2,000
Rated impulse withstand voltage Uimp 4000V
Connection From top and bottom, from bottom and top

 

 

2.3 The residual current breaking times

In (A) I△n (A) Breaking time when the residual current assumes the following values (s)
I△n 2I△n 5I△n 5A, 10A, 20A, 50A, 100A, 200A, 500A(a) I△t(b)
6~40 0.01, 0.03, 0.1, 0.3 0.1 0.05 0.04 0.04 0.04

a. For tests of 5A, 10A, 20A, 50A, 100A, 200A and 500A, the current values beyond the lower limit of over-current instantaneous tripping are not tested.

B. Tests are done when I△t is equal to the lower limit current of over-current instantaneous tripping of type B and type C.

 

 

2.4 The over-current protection characteristics

No. Rated current In (A) Initial state Test current (A) Specified time (t) Expected result Remarks
a 6 ~ 40 Cold state 1.13 In t ≥ 1h Non-tripping  
b Immediately after sequence a 1.45 In t < 1h Tripping Increase to the specified current within 5s after test item a.
c Cold state 2.55 In 1s < t < 60s Tripping  
d Cold state 3 In t ≥ 0.1s Non-tripping Type B
5 In t < 0.1s Tripping
5 In t ≥ 0.1s Non-tripping Type C
10 In t < 0.1s Tripping

 

3. Outline and installation dimensions (mm)

 

Product Description:

RCBO Type B is a Residual Current Operated Circuit Breaker which is designed to provide protection against electric shock and fire caused by overload, short circuit and earth leakage. It provides superior protection and safety for both residential and commercial applications. This product is compliant with the IEC/EN 61009-1 and AS/NZS 61009.1 standards, and offers an impressive 2000 Mechanical Life. It is available in 1P+N poles, and has a wide range of rated current options (6A 10A 16A 20A 25A 32A 40A 50A Inm). RCBO Type B is the ideal choice for reliable and safe electrical circuit protection.

 

Features:

  • Product Name: RCBO Type B
  • Residual Current Operated Circuit Breaker
  • Rated Residual Operating Current: 0.01A, 0.03A, 0.1A, 0.3A
  • Rated impulse withstand voltage Uimp: 6000V
  • Frame size rated current Inm: 50A
  • Poles: 1P+N
  • Classified by Type of Instantaneous Tripping: Type B: (3 ~ 5) In, Type C: (5 ~ 10) In

 

Applications:

RCBO Type B, manufactured by HAROK with model number VKL003, is a 1P+N circuit breaker and is made in CHINA. It is rated at AC240V with a rated residual non-operating current of 0.005A, 0.015A, 0.05A, 0.15A and a rated residual making and breaking capacity of I△m 500A. This RCBO Circuit Breaker offers superior electrical life of 2000.

RCBO Type B is suitable for various applications, especially for the protection of sensitive appliances that require a very low residual current. It is also suitable for circuit protection in places with frequent on-off operations, such as kitchen, bathroom, and laundry. RCBO Type B can be used to protect circuits in places such as office buildings, factories, and warehouses.

RCBO Type B is also suitable for residential and commercial applications, such as in residential buildings, apartments, and condominiums. It is also ideal for commercial applications, such as in shops, restaurants, and retail stores. In addition, it can be used to protect electrical circuits in hotels, hospitals, and other public places.

Furthermore, RCBO Type B is suitable for the protection of lighting circuits, air conditioning systems, and other electrical circuits that are subject to frequent on-off operations. It is also suitable for the protection of motors, pumps, and other electrical equipment in industrial applications.

 

Technical Parameters:

Property Description
Standard IEC/EN 61009-1, AS/NZS 61009.1
Connection From Top And Bottom, From Bottom And Top
Type of Instantaneous Tripping Type B: (3 ~ 5) In, Type C: (5 ~ 10) In
Rated Residual Operating Current 0.01A, 0.03A, 0.1A, 0.3A
Electrical Life 2000
Mechanical Life 2000
Product Name Mini RCBO Type B
Frame size rated current Inm 50A
Rated residual making and breaking capacity I△m 500A
Rated Current 6A 10A 16A 20A 25A 32A 40A 50A

 

Customization:

RCBO Type B - HAROK VKL003
  • Brand Name: HAROK
  • Model Number: VKL003
  • Place of Origin: CHINA
  • Mechanical Life: 2000
  • Rated Voltage: AC240V
  • Standard: IEC/EN 61009-1, AS/NZS 61009.1
  • Type: Type B
  • Classified by Type of Instantaneous Tripping: Type B: (3 ~ 5) In, Type C: (5 ~ 10) In

HAROK VKL003 RCBO Type B is a type of Residual Current Operated Circuit Breaker which can provide a reliable and effective protection against electric shock. It has a rated voltage of AC240V and a mechanical life of 2000. It is certified by IEC/EN 61009-1, AS/NZS 61009.1 and classified by Type of Instantaneous Tripping as Type B: (3 ~ 5) In, Type C: (5 ~ 10) In.

 

Packing and Shipping:

Packaging and Shipping:
RCBO Type B products are packed in 5-ply cardboard boxes, foam lined, with a corrugated wrap. Each box contains 10 pieces. The boxes are shrink-wrapped and then placed on a pallet. The pallet is then stretch-wrapped for shipping.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2003

  • Employee Number:

    >100

  • Ecer Certification:

    Verified Supplier

  YUEQING VORAX ELECTRIC CO., LTD (hereinafter referred to as "VORAX"), founded in 2003, has established itself as a prominent player in the low voltage electrics industry in China. With a prime location in Liushi Town, Yueqing city, Zhejiang Province, VORAX benefits from being s...   YUEQING VORAX ELECTRIC CO., LTD (hereinafter referred to as "VORAX"), founded in 2003, has established itself as a prominent player in the low voltage electrics industry in China. With a prime location in Liushi Town, Yueqing city, Zhejiang Province, VORAX benefits from being s...

+ Read More

Get in touch with us

  • Reach Us
  • Yueqing Vorax Electric CO.,LTD
  • Liuhuang Road, Liushi Town, Yueqing City, Zhejiang Province
  • https://www.rccbbreaker.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement