China factories

China factory - Newscen Biopharm Co., Limited

Newscen Biopharm Co., Limited

  • China,Tianjin ,Tianjin
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China In Vitro Diagnostic 97.5% Accuracy Syphilis Rapid Test Kit
China In Vitro Diagnostic 97.5% Accuracy Syphilis Rapid Test Kit

  1. China In Vitro Diagnostic 97.5% Accuracy Syphilis Rapid Test Kit
  2. China In Vitro Diagnostic 97.5% Accuracy Syphilis Rapid Test Kit
  3. China In Vitro Diagnostic 97.5% Accuracy Syphilis Rapid Test Kit
  4. China In Vitro Diagnostic 97.5% Accuracy Syphilis Rapid Test Kit

In Vitro Diagnostic 97.5% Accuracy Syphilis Rapid Test Kit

  1. MOQ: 10 Boxes or 400 Kits (40 Kits/Box)
  2. Price: Negotiable as per Order Quantity
  3. Get Latest Price
Payment Terms T/T, Western Union, MoneyGram
Supply Ability 100,000 Kits Per Day
Delivery Time 8 days
Packaging Details 40 Kits/Box, 50 Boxes/Carton, 317g/Box, 18kgs/Carton, Box Size: 250x125x65mm, Carton Size: 650x510x330mm
Methodology Colloidal Gold
Shelf Life 2 Years
OEM/ODM Available
Usage For In Vitro Diagnostic Use Only
Temperature Request 2-30°C
Manufacturer/Trader Manufacturer
Brand Name Newscen
Model Number TP (Treponema Pallidum) Syphilis
Certification ISO9001, CE, TUV, FDA
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, Western Union, MoneyGram Supply Ability 100,000 Kits Per Day
Delivery Time 8 days Packaging Details 40 Kits/Box, 50 Boxes/Carton, 317g/Box, 18kgs/Carton, Box Size: 250x125x65mm, Carton Size: 650x510x330mm
Methodology Colloidal Gold Shelf Life 2 Years
OEM/ODM Available Usage For In Vitro Diagnostic Use Only
Temperature Request 2-30°C Manufacturer/Trader Manufacturer
Brand Name Newscen Model Number TP (Treponema Pallidum) Syphilis
Certification ISO9001, CE, TUV, FDA Place of Origin China
High Light In Vitro Syphilis Rapid Test Kit97.5% Syphilis Rapid Test Kit97.5% Syphilis Rapid Diagnostic Kit

Treponema Pallidum(TP) Rapid Diagnostic Kit (Colloidal Gold)

 

For the qualitative detection of Syphilis antibodies in serum/plasma and whole blood

 

Treponema Pallidum Syphilis Rapid Test Kit TP Home Use In Vitro Diagnostic Device

 

Main Features

 

☀ High Sensitivity: 100%

☀ Specificity: 100%

☀ Reliable: Accuracy higher than 97.5%, early detection of the presence of TP Antibody

☀ Convenient: Room Temperature Storage, Built-In Control

☀ Simple: No Instrument Required

☀ Fast: Results in 5-30 minutes, strong positive results may be observed promptly within 3 minutes

☀ Certified by Authoritative Certification System and Standards

☀ Winner of "the National Rapid Diagnostic Kit for Clinical Performance Assessment"

 

 

Intended Use


The Syphilis Rapid Diagnostic Test is a qualitative test for the detection of antibodies to Syphilis in human serum/plasma and whole blood. It is considered as an initial screening test for Syphilis antibodies. All positive specimens must be confirmed with Western Blot or other qualified EIA.

 

Principle


Syphilis Rapid Diagnostic Test is a chromatographic immunoassay (CIA) for the detection of antibodies to Syphilis in human serum or plasma. Syphilis specific antigens are precoated onto membrane as a capture reagent on the test region.

 

During the test, specimen is allowed to react with the colloidal gold particles, which have been labeled with Syphilis specific antigens. Antibodies to Syphilis, if present, a red colored band will develop on the membrane in proportion to the amount of Syphilis antibodies present in the specimen.

 

Absence of this red colored band in the test region suggests a negative result. To serve as a procedural control, a red colored band in the control region will always appear regardless the presence of antibodies to Syphilis. The RDT is simple, rapid, sensitive and specific.

 

 

Reagents and Materials Provided

 

☀ Blood diluent in a dropper bottle.

☀ One sealed pouched cassette with desiccant & a disposable pipe.

☀ One piece of operating instruction with 40 test pouches.

 

Sample Collection and Preparation

 

Whole Blood ( Finger stick Specimens)

☀ Clean the area to be lanced with an alcohol swab.

☀ Squeeze the end of the fingertip and pierce it with a sterile lancet.

☀ Wipe away the first drop of blood with sterile gauze or cotton.

☀ Allow the second drop to flow directly into a sample well.

 

Plasma

☀ Have a certified phlebotomist collect whole blood into a purple, blue or green top collection tube (containing EDTA, citrate or heparin, respectively) by veinpuncture.

☀ Separate the plasma by centrifugation.

☀ Carefully withdraw the plasma for testing or label and store it at 4°C for up to five days. Plasma may be frozen at -20°C for at least three months.

 

Serum

☀ Have a certified phlebotomist collect whole blood into a red top collection tube (containing no anticoagulants) by veinpuncture.

☀ Allow the blood to clot.

☀ Separate the serum by centrifugation.

☀ Carefully withdraw the serum for testing or label and store it at 4°C for up to five days. Serum may be frozen at -20°C for at least three months.

 

 

Assay Procedure

 

Serum or Plasma Sample

Add 2 drops of serum or plasma into sample well. Observe the result in 120 minutes.

 

Whole Blood Sample

Add 1 drop of whole blood into sample well, after all blood completely absorbed. Add 2 drop of whole blood diluent. Observe the result in 20 minutes.

 

 

Interpretation of Results

 

 

Negative: No apparent band in the test region (T), Only one red band appears in the control region (C). This indicates that no TP antibodies have been detected.


Positive: In addition to one red band in the control region (C), a red band will appear in the test region (T). This indicates that the specimen contains TP antibodies.


Invalid: If no band appears in the control region(C), regardless of the presence or absence of band in the test region (T). It indicates a possible error in performing the test. The test should be repeated using a new device.
 

Warning and Precautions

 

☀ FOR IN VITRO DIAGNOSTIC USES ONLY.

☀ All patient samples should be treated as if capable of transmitting diseases.

☀ Do not interchange reagents from different lots or use test kit beyond expiration date.

☀ Icteric, lipemic, hemolysed, heat treated and contaminated sera may cause erroneous results.

 

Storage


Store the test kits at temperature 4-30°C,in the sealed pouch for the duration of the shelf life (24 months).

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Seller

  • Year Established:

    2003

  • Employee Number:

    200~300

  • Ecer Certification:

    Active Member

Newscen Biopharm Co., Limited is a professional manufacturer of in vitro diagnostic products and related supporting apparatuses, which is jointly founded by Tianjin Pharmaceutical Group, Tianjin Zhongxin Pharmaceuticals Co., Ltd and oversea Chinese entrepreneurs.   Founded in 2003, the co... Newscen Biopharm Co., Limited is a professional manufacturer of in vitro diagnostic products and related supporting apparatuses, which is jointly founded by Tianjin Pharmaceutical Group, Tianjin Zhongxin Pharmaceuticals Co., Ltd and oversea Chinese entrepreneurs.   Founded in 2003, the co...

+ Read More

Get in touch with us

  • Reach Us
  • Newscen Biopharm Co., Limited
  • No. 65 Sixth Ave .,TEDA Tianjin , 300457 P. R. China
  • https://rapid-testkit.ecer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement