Nominal voltage | 380V/400V/415V |
Protection | Overvoltage |
Type | On-line pure sine wave |
Phase | 3 phase+N+G |
Wave form | Pure Sine Wave |
Battery type | Lead Acid Battery |
Transfer time | Zero Conversion |
Capacity | 30KVA(3Ph/1Ph) |
Frequency | 50/60Hz |
Brand Name | ZGD |
Model Number | ZGD310 30 |
Certification | CE |
Place of Origin | SHENZHEN |
View Detail Information
Explore similar products
10KVA 8KW Industrial Online UPS Systems With External Battery
15KVA 12KW Industrial Online UPS battery backup Pure Sine Wave 3 Phase
400V 415V 20KVA 16KW UPS Industrial Online UPS Uninterruptible Power Supply
3 Phase 10KVA 8KW Online UPS Systems With External Battery Backup
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 1000 sets per month |
Delivery Time | 7~15 working days | Nominal voltage | 380V/400V/415V |
Protection | Overvoltage | Type | On-line pure sine wave |
Phase | 3 phase+N+G | Wave form | Pure Sine Wave |
Battery type | Lead Acid Battery | Transfer time | Zero Conversion |
Capacity | 30KVA(3Ph/1Ph) | Frequency | 50/60Hz |
Brand Name | ZGD | Model Number | ZGD310 30 |
Certification | CE | Place of Origin | SHENZHEN |
High Light | 24KW Industrial Online UPS ,30KVA Industrial Online UPS ,24KW Long Backup Time UPS |
Industrial Online UPS 30KVA 24KW Three Phase Long Backup Time Pure Sine Wave Ups
Application:
Petroleum, chemical industry, gas and power station and so on.
Static Switch:
Not sync automatically switch:
When the bypass of UPS and inverter are not synchronized,
ZGD310 C can automatically implement not
sync switch, such as city electricity surge pulse width
<5ms can ensure no power cutoff.
When the bypass exceed limit, UPS will detect the
bypass every 20ms, as long as the phase angle
difference of bypass and inverter come back to the
normal range, not synchronized bypass switch can be
realized.
Intelligent Monitoring:
Via RS232/RS485, passive contact and power transmitter
signal to transfer working status of UPS and real-time data
to the DCS system, finally realize intelligent monitoring.
Model Papacity(KVA) | 10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | |
Capacity | 8KW | 12KW | 16KW | 24KW | 32KW | 48KW | 64KW | 80KW | |
lnput | |||||||||
Rated voltage | 400 Vac three-phase | ||||||||
Voltage range | ±20% | ||||||||
Frequency range | 50/60HZ±5% | ||||||||
Power factor | ≥0.8 | ||||||||
Current harmonic distortion | <5%with harmonic filter | ||||||||
Soft Start | 0-100% in10" | ||||||||
Bypass Input
| |||||||||
Rated voltage | 230Vac single-phase | ||||||||
Permitted voltage range | ±15%(selectable from ±10% to ±25% from front panel) | ||||||||
Rated frequency | 50/60Hz | ||||||||
Permitted frequency range | ±2%(selectable from ±1% to ±5% from front panel)
| ||||||||
Standard features | BackFeed portection; split bypass line | ||||||||
Batteries | |||||||||
Type | Maintenance-free lead-acid VRLA AGM / GEL;NICd | ||||||||
Maximum recharge current(A) | 0.2 X C10 | ||||||||
DC Voltage | 384VDC | 432VDC | |||||||
AC ripple voltage | <1% | ||||||||
Inverter output
| |||||||||
Number of phases | 1 | ||||||||
Rated voltage(V) | 230Vac single-phase | ||||||||
Regulation of the output voltage | 220÷244Vac phase/neutral(from contril panel)
| ||||||||
Crest factor(Ipeak/Irms) | 3:1 | ||||||||
Static stability | ±1% | ||||||||
Dynamic stability | ±5% | ||||||||
Frequency | 50/60Hz configurable | ||||||||
Overload | 110% 125% 150% of the rated current for 5h/10'/1' | ||||||||
Frequency stability | ±0.05% on mains failure | ||||||||
System | |||||||||
Remote signaling | Volt free contacts | ||||||||
Remote controls | EPO and Bypass | ||||||||
Communication | RS232 + romote contacts | ||||||||
Operation temperature | 0℃/ + 40℃ | ||||||||
Relative humidity | <95% non condensing | ||||||||
Colour | Light grey (RAL 7035) | ||||||||
Noise | 54dBA at 1m | 60dBA at 1m | 65dBA at 1m | ||||||
Protection degree | IP42 | ||||||||
Efficiency Smart Mode | up to 98% | ||||||||
Compliance | Safety:EN 62040-1-1(Directive 2006/95/EC); EMC:6200-2(Directive 2004/108/EC) | ||||||||
Weight(KG)N.W | 200 | 220 | 230 | 290 | 340 | 440 | |||
Dimensions:(WxDxH)mm | 600*800*1900 |
Company Details
Business Type:
Manufacturer,Exporter,Seller
Total Annual:
1000000-5000000
Employee Number:
zgd001~zgd500
Ecer Certification:
Site Member
As a manufacturer with over 10 years of experience, Shenzhen ZGD Technology Co., Ltd. has more than 10 production lines which can produce 100,000 pieces of UPS every month. Over 10% of our staff members are engineers and professional technicians and more than 400 are skilled workers. Our company spe... As a manufacturer with over 10 years of experience, Shenzhen ZGD Technology Co., Ltd. has more than 10 production lines which can produce 100,000 pieces of UPS every month. Over 10% of our staff members are engineers and professional technicians and more than 400 are skilled workers. Our company spe...
Get in touch with us
Leave a Message, we will call you back quickly!