Payment Terms | T/T |
Supply Ability | 100 units per month |
Delivery Time | 15 word days |
Packaging Details | Consultation with customers |
Motor Speed | 960-2900 rpm |
Packing Ways | Wooden Case |
Impeller Test | Ultrasonic flaw detection |
Motor Brand | Siemens/ABB |
System Type | Various models |
Air Volume | 1000-100000 m3/h |
Impeller Testing | Dynamic Blancing Adjusting |
Drive | Coupling Driven |
Electric Current Type | AC |
Voltage | 220V/380V |
Usage | Induced draft fan |
Bearing Cooling | Air cooling or Circulating Water cooling |
Blade Number | 4-73、5-48、6-51、9-19 |
Brand Name | QiaoDa |
Model Number | 4-68-8D |
Certification | YES |
Place of Origin | China |
View Detail Information
Explore similar products
Centrifugal Boiler Induced Draft Fan G4-73 High Pressure Dust Collector Fan
Industrial 220V/380V Exhaust Ventilation Fan 2.2KW High Air Volume Fan
FRP Centrifugal Fan 18.5KW Siemens Motor Dust Removal Fan 1000-15000 M3/H
4-72 Industrial Centrifugal Fan 5.5kw Air Capacity Induced Draft Blower 5000
Product Specification
Payment Terms | T/T | Supply Ability | 100 units per month |
Delivery Time | 15 word days | Packaging Details | Consultation with customers |
Motor Speed | 960-2900 rpm | Packing Ways | Wooden Case |
Impeller Test | Ultrasonic flaw detection | Motor Brand | Siemens/ABB |
System Type | Various models | Air Volume | 1000-100000 m3/h |
Impeller Testing | Dynamic Blancing Adjusting | Drive | Coupling Driven |
Electric Current Type | AC | Voltage | 220V/380V |
Usage | Induced draft fan | Bearing Cooling | Air cooling or Circulating Water cooling |
Blade Number | 4-73、5-48、6-51、9-19 | Brand Name | QiaoDa |
Model Number | 4-68-8D | Certification | YES |
Place of Origin | China | ||
High Light | dust collector draft induction fan ,low noise boiler induced draft fan ,Custom boiler induced draft fan |
Custom variable frequency low noise boiler dust collector induced draft fan
The centrifugal fan uses a high-speed rotating impeller to accelerate the gas, then
decelerates and changes the flow direction to convert the kinetic energy into potential
energy (pressure). In a single-stage centrifugal fan, the gas enters the impeller from
the axial direction, changes radial as the gas flows through the impeller, and then
enters the diffuser. In the diffuser, the gas changes the direction of flow and the
increase in the section area of the pipe slows down the gas flow, which converts
kinetic energy into pressure energy. * The pressure increase mainly occurs in the
impeller, followed by the diffusion process. In a multistage centrifugal fan, a reflow
is used to make the air flow into the next blade to produce a higher pressure.
Model number | Rotational speed (r/min) | Total pressure (Pa) | Flow rate (m³/b) | Internal efficiency (%) | Internal power (KW) | Shaft power (KW) | Required power (KW) | |
Motor(KW) | ||||||||
8D | 1AS0 | 2745 | 11000 | 75 | 11.2 | 11.4 | 13.1 | 15 |
2701 | 13200 | 78 | 12.7 | 13 | 14.9 | |||
2612 | 15400 | 81 | 13.8 | 14.1 | 16.2 | 18.5 | ||
2479 | 17600 | 83 | 14.6 | 14.8 | 17 | |||
2346 | 19800 | 82 | 15.7 | 16.I | 18.5 | 22 | ||
2214 | 22000 | 80 | 16.9 | 17.3 | 19.8 | |||
2036 | 24200 | 77 | 17.8 | 18,I | 20.9 | |||
1859 | 26400 | 74 | 18.4 | 18.8 | 21.6 | |||
9D | 1450 | 3474 | 15700 | 75 | 20.2 | 20.6 | 23.7 | 30 |
3418 | 18800 | 78 | 22.9 | 23.4 | 26.9 | |||
3306 | 21900 | 81 | 24.8 | 25.3 | 29.1 | |||
3138 | 25000 | 83 | 26.3 | 26.8 | 30.8 | |||
2969 | 28100 | 82 | 28.3 | 28.8 | 33.2 | 15 | ||
2801 | 31300 | 80 | 30.4 | 31.】 | 35.7 | |||
2577 | 34400 | 77 | 32 | 32.6 | 37.5 | |||
2353 | 37500 | 74 | 33.1 | 33.8 | 38.9 | |||
10D | 1450 | 4289 | 21500 | 75 | 34.2 | 34.9 | 40. | 45 |
4220 | 25800 | 78 | 38.8 | 39.6 | A5.5 | |||
4081 | 30000 | 81 | 42 | 42.8 | 49.3 | 55 | ||
3874 | 34300 | 83 | 44.S | 4S. | S2.2 | |||
3666 | 38600 | 82 | 7.9 | 48.9 | S6.3 | 75 | ||
3459 | 42900 | 80 | 51.5 | S2.6 | 605 | |||
3182 | 47200 | 77 | S4.2 | 55.3 | 63.6 | |||
2905 | 51500 | 74 | S6.2 | S7.3 | 65.9 | |||
1ID | 】450 | 5190 | 28600 | 75 | 55 | 56 | 65 | 75 |
5106 | 34300 | 78 | 62 | 64 | 73 | |||
4938 | 40000 | 81 | 68 | 69 | 79 | 90 | ||
4688 | 45700 | 83 | 72 | 73 | 84 | |||
4436 | S1400 | 82 | 77 | 79 | 9】 | 110 | ||
4185 | 57100 | 80 | 83 | 85 | 97 | |||
3850 | 62800 | 77 | 87 | 89 | 102 | |||
3515 | 68500 | 74 | 90 | 92 | 106 |
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2003
Total Annual:
5500000-6900000
Employee Number:
80~100
Ecer Certification:
Verified Supplier
About Us: We are committed to delivering innovative and reliable solutions for industrial air quality management. With over two decades of experience in designing, manufacturing, and installing high-performance dust collectors, we have established ourselves as a leading name in the field. ... About Us: We are committed to delivering innovative and reliable solutions for industrial air quality management. With over two decades of experience in designing, manufacturing, and installing high-performance dust collectors, we have established ourselves as a leading name in the field. ...
Get in touch with us
Leave a Message, we will call you back quickly!