Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"8-24VDC 50mA Interface PT1\/4 Calibration Method Air Mass Flow Rate Controller","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/25\/de\/c7c498f6538a251fb7626e2cf68b-200x200-1\/8_24vdc_50ma_interface_pt1_2f4_calibration_method_air_mass_flow_rate_controller.jpg","attrs":{"Brand Name":"Consensic","Model Number":"CAFS5032","Place of Origin":"WUXI","Minimum Order Quantity":"Please contact us for details"}}
{"title":"CMF9019 Communication Method RS485 MODBUS Medium Temperature -10-65\u2103 Ambient","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/10\/28\/5382497b86ba6157d8a9872c5ff7-200x200-1\/cmf9019_communication_method_rs485_modbus_medium_temperature_10_65_e2_84_83_ambient_temperature_25_85_e2_84_83.jpg","attrs":{"Brand Name":"Consensic","Model Number":"CMF9019","Certification":"PTC23091116101C-CN01","Place of Origin":"WUXI"}}
{"title":"20ms Response Time Air Flow Controller Analog Output 1 To 5V","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/59\/05\/c773a7e4e6b4022db16cce3fd9ed-200x200-1\/20ms_response_time_air_flow_controller_analog_output_1_to_5v.jpg","attrs":{"Brand Name":"Consensic","Model Number":"CAFS4000","Minimum Order Quantity":"Please contact us for details","Price":"Offline conversation or face-to-face discussion"}}
{"title":"CAFS5025 Flow Range 0-1200 SLPM Calibration Method Air, 20\u2103, 101.325 kPa","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/39\/56\/c697bc69c7e331e3738fd1b66c2d-200x200-1\/cafs5025_flow_range_0_1200_slpm_calibration_method_air_2c_20_e2_84_83_2c_101_325_kpa.jpg","attrs":{"Brand Name":"Consensic","Model Number":"CAFS5025","Place of Origin":"WUXI","Minimum Order Quantity":"Please contact us for details"}}
{"title":"CAFS5019 Interface Air, 20\u00b0C, 101.325 kPa Output Mode Analog (1-5 VDC), 4-20 mA","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/52\/43\/d39f6bfbe1ac63ea49899a6a3c03-200x200-1\/cafs5019_interface_air_2c_20_c2_b0c_2c_101_325_kpa_output_mode_analog_281_5_vdc_29_2c_4_20_ma_28matching_29.jpg","attrs":{"Brand Name":"Consensic","Model Number":"CAFS5019 CAFS5000 series","Certification":"PTC23041812701C-CN01","Place of Origin":"WUXI"}}
{"title":"CMF5032 CAFS5032 with display Quick response time (20 ms response time)","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/8d\/d1\/6f91c60c1ac8d7e4933a7a194542-200x200-1\/cmf5032_cafs5032_with_display_quick_response_time_2820_ms_response_time_29.jpg","attrs":{"Brand Name":"Consensic","Model Number":"CMF5032","Certification":"PTC23041812701C-CN01","Place of Origin":"WUXI"}}
{"title":"CAFS6000 Flow range0-10000SCCM Calibration conditions0\u2103, 1 standard atmosphere","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/df\/73\/4225037d1010fb934b671509e90b-200x200-1\/cafs6000_flow_range0_10000sccm_calibration_conditions0_e2_84_83_2c_1_standard_atmosphere.jpg","attrs":{"Brand Name":"Consensic","Model Number":"CAFS6000","Certification":"PTC22072602101C-CN01","Place of Origin":"WUXI"}}
Trustworthy Manufacturer: Rely on a reputable manufacturer for consistent quality and service.
Professional Manufacturer: Specialize in manufacturing, providing expertise and reliability.
Stable Inventory: Ensure availability and fast delivery of products.
Quality Assurance: Strictly control details to guarantee product quality.
Fast Processing: Efficient processing ensures timely delivery of high-quality products.
Intimate After-Sales: Provide comprehensive after-sales support for peace of mind.
Features:
High Accuracy: Achieves 1.5% F.S accuracy, ensuring precise flow measurement.
Linear Output: No temperature compensation required, simplifying usage.
Long-Term Stability: Minimal zero drift ensures consistent performance over time.
Fast Response Time: Offers a rapid 20 ms response time for real-time monitoring.
Wide Flow Range: Covers a range of 0-60m/s, with impact resistance up to 100g.
Solid-State Sensing Core: Resists clogging and pressure shocks for reliable operation.
Analog Output: Provides 1-5 V analog output, with digital RS485 communication available.
Compatibility: Suitable for measuring relatively humid gases, enhancing versatility.
Wide Operating Conditions: Operates reliably in temperatures from -10°C to 65°C, with storage temperature up to 85°C and humidity up to 100% RH.
Resistant to Condensation: Withstands condensation for reliable performance in various environments.
Technical Parameters:
Functional Items
8-24VDC 50mA Interface PT1/4 Calibration Method Air Mass Flow Rate Controller 101.325kPa
Performance Parameters
Unit
Power Supply
8~24VDC,50mA
Precision
±1.5
Response Time
65
Maximum Pressure
0.8
Methods of Communication
RS485 (MODBUS)
Output Mode
Analog outputs 1-5 VDC, 4-20mA
Temperature
Medium temperature (-10~65)℃, ambient temperature (-25~85)℃
Interface
PT1/4
Calibration Method
Air, 20°C, 101.325kPa
Overall Material
Stainless steel
Applications:
Industrial
Medical
Petroleum
Instrumentation
Gas
Chemical
Smelting
Food Processing
Mechanical and Electrical Equipment
Product Description:
The CAFS5032 medical flow sensors utilize microelectromechanical system (MEMS) flow sensing chips for precise measurement and control of clean, dry gas flows. With unique packaging technology, these sensors ensure high sensitivity, reliability, stability, and cost-effectiveness. They are based on a MEMS flow sensing unit and a high-precision digital processing and calibration circuit (MCU), ensuring accurate flow measurement without the need for external calibration. The sensors support digital RS485 communication and analog output for easy integration and versatile usage. They operate effectively in a wide range of temperatures and humidity levels, making them suitable for diverse applications.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Agent,Seller,Other
Year Established:
2009
Total Annual:
1000-1500
Employee Number:
50~100
Ecer Certification:
Verified Supplier
ConsensicInc.
Sensorchipandsolutionprovider
Pressuresensor,flowsensor,humidity
sensor,etc.
China
Wuxi Consensic Electronic Technology Co., Ltd
Room 214072, B5401, No. 86 Dicui Road, Binhu District, Wuxi City, Jiangsu Province
Phone:+86 510.85122279
Fax:+...
ConsensicInc.
Sensorchipandsolutionprovider
Pressuresensor,flowsensor,humidity
sensor,etc.
China
Wuxi Consensic Electronic Technology Co., Ltd
Room 214072, B5401, No. 86 Dicui Road, Binhu District, Wuxi City, Jiangsu Province
Phone:+86 510.85122279
Fax:+...