China CAFS5008 latus rectum 8 joggle 3/8’’ L 83 H 27 W 35 d 8
China CAFS5008 latus rectum 8 joggle 3/8’’ L 83 H 27 W 35 d 8

  1. China CAFS5008 latus rectum 8 joggle 3/8’’ L 83 H 27 W 35 d 8

CAFS5008 latus rectum 8 joggle 3/8’’ L 83 H 27 W 35 d 8

  1. MOQ: Please contact us for details
  2. Price: Offline conversation or face-to-face discussion
  3. Get Latest Price
Payment Terms L/C/Ade/Pellet/Texi Union, MoneyGram, Alipay, and business-to-business payments
Supply Ability 999
Delivery Time 3-7 work days
interface G3/8Customizable
Flow range 20/50/100/200/300slpm can be customized
Methods of Communication 485/I2C optional
temperature Medium temperature (-10~65)°C
Response time 20ms optional
Overall material Aluminum alloy (stainless steel optional)
Brand Name Consensic
Model Number CAFS5008
Certification PTC23041812701C-CN01
Place of Origin WUXI

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C/Ade/Pellet/Texi Union, MoneyGram, Alipay, and business-to-business payments Supply Ability 999
Delivery Time 3-7 work days interface G3/8Customizable
Flow range 20/50/100/200/300slpm can be customized Methods of Communication 485/I2C optional
temperature Medium temperature (-10~65)°C Response time 20ms optional
Overall material Aluminum alloy (stainless steel optional) Brand Name Consensic
Model Number CAFS5008 Certification PTC23041812701C-CN01
Place of Origin WUXI

 

Installation and Usage Guide

Product Orientation

This product is recommended for horizontal installation, though it can be installed vertically if site conditions are limited. Ensure that the arrow on the base indicates the direction of flow. Connect the media to the inlet and outlet ports accordingly.

Installation Steps

  1. Inspect the Flowmeter:

    • Ensure the flowmeter has no visible damage.
  2. Prepare the Pipes:

    • Connect and clean the pipes before installation.
  3. Install the Flowmeter:

    • Follow these steps for proper installation:

      1. Ensure Measurement Accuracy:

        • Connect the upstream end of the flowmeter first.
        • The upstream straight pipe section should meet a minimum requirement of 10DN.
        • The downstream straight pipe section should meet a minimum requirement of 5DN.
      2. Sealing Material:

        • Do not allow sealing material to penetrate into the pipe during installation.
      3. Connect Power Cable:

        • Pay attention to the wiring polarity.
        • Ensure the input DC voltage is between 8-24 VDC.
      4. Signal Line Connection:

        • If needed, connect the signal line to the corresponding user interface correctly.
    • Note: Ensure the airflow direction is consistent with the sensor’s airflow indication direction. Once the sensor lead line is connected correctly, turn on the power supply to start operation.

Installation Notes

  1. Pipe Cleanliness:

    • Clear impurities from the pipe before installation to avoid damage to the flowmeter. The inner wall of the pipe should be clean and free of scale.
  2. Fixed Parts:

    • Do not release the fixed parts of the flowmeter arbitrarily.
  3. Installation Stress:

    • Ensure no installation stress is applied to the flowmeter to prevent damage.
  4. Environmental Conditions:

    • Avoid strong magnetic field interference and violent vibration environments.
  5. Stable Medium Flow:

    • Ensure stable medium flow. Operate the valve slowly; do not rush to open or close it.

Product Specifications

Model Latus Rectum Joggle L H W d Specifications
CAFS 5008 8 3/8’’ 83 27 35 8 20 / 50 / 100 / 200 / 300 units (L/MIN)

Functional Items

CAFS5008 latus rectum 8 joggle 3/8’’ L 83 H 27 W 35 d 8 Performance Parameters

Parameter Unit Remarks
Flow range 20/50/100/200/300 slpm Customizable
Power Supply Voltage 8~24VDC, 50mA Selectable
Accuracy ±1.5% FS  
Response time 20 ms Selectable
Maximum pressure 0.8 MPa Customizable
Communication mode 485/I2C Selectable
Output method Analog outputs of 1-5V  
Medium temperature -10~65 ℃  
Joggle G3/8 Customizable
Levels of protection IP40  
Calibration method Air, 0℃, and / 20℃ 101.325kPa  
Overall material Aluminum alloys (stainless steel optional)  

This guide outlines the correct installation and usage procedures for the CAFS5008 latus rectum 8 joggle 3/8’’ L 83 H 27 W 35 d 8 to ensure optimal performance and longevity.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Agent,Seller,Other

  • Year Established:

    2009

  • Total Annual:

    1000-1500

  • Employee Number:

    50~100

  • Ecer Certification:

    Verified Supplier

ConsensicInc. Sensorchipandsolutionprovider Pressuresensor,flowsensor,humidity sensor,etc.   China Wuxi Consensic Electronic Technology Co., Ltd Room 214072, B5401, No. 86 Dicui Road, Binhu District, Wuxi City, Jiangsu Province Phone:+86 510.85122279 Fax:+... ConsensicInc. Sensorchipandsolutionprovider Pressuresensor,flowsensor,humidity sensor,etc.   China Wuxi Consensic Electronic Technology Co., Ltd Room 214072, B5401, No. 86 Dicui Road, Binhu District, Wuxi City, Jiangsu Province Phone:+86 510.85122279 Fax:+...

+ Read More

Get in touch with us

  • Reach Us
  • Wuxi Consensic Electronic Technology Co., Ltd.
  • No.86,Dicui Road,B5Building, Fourth Floor,Room 401
  • https://www.pressureflowsensor.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement