China Aluminum Profile GMP Cleanroom , 0.45m/S Iso Class 8 Clean Room
China Aluminum Profile GMP Cleanroom , 0.45m/S Iso Class 8 Clean Room

  1. China Aluminum Profile GMP Cleanroom , 0.45m/S Iso Class 8 Clean Room

Aluminum Profile GMP Cleanroom , 0.45m/S Iso Class 8 Clean Room

  1. MOQ: 1 Set
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms T/T, L/C
Supply Ability 1000 Sets/Month
Delivery Time 14-30 Workdays
Packaging Details Plywood Box
Project GMP Cleanroom
Style Simple
Frame Aluminum Profile
Wall Magnesium Sandwich Panel
Characteristic Control Air Cleanliness
Using Field Workshop
Brand Name GCC
Certification QS/SC
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C Supply Ability 1000 Sets/Month
Delivery Time 14-30 Workdays Packaging Details Plywood Box
Project GMP Cleanroom Style Simple
Frame Aluminum Profile Wall Magnesium Sandwich Panel
Characteristic Control Air Cleanliness Using Field Workshop
Brand Name GCC Certification QS/SC
Place of Origin China
High Light 0.45m/S Iso Class 8 Clean RoomAluminum Profile GMP Cleanroom0.45m/S GMP Cleanroom

GMP Cleanroom

GMP requires a cleanroom or clean area for pharmaceutical manufacturing. Within the GMP there are further standards for the materials used in the construction of a cleanroom or area compliant with GMP. All materials must be able to withstand frequent cleaning and disinfection. Additionally, materials must be free of cracks, smooth and level, and able to interlock seamlessly. Particulate materials may not be used due to the risk of contamination. Aside from GMP compliance, other factors such as durability, ease of installation, and cost come into consideration when designing a cleanroom. At Clean we will guide you through the design process step by step to ensure that both GMP standards, your needs, and your budget are all satisfied.

 

GMP Cleanroom Walls

 

Cleanroom walls and ceilings should be bright and clean, fade resistant, smooth and even, and easy to clean. Common materials for cleanroom walls include stone, Choi steel, and Terrazzo, which are often coated in a special paint. For especially damp production environments that are difficult to keep clean, Vitrolite (porcelain) walls may be used. However, in this case it is crucial that the material is applied evenly and sealed with no cracks to minimize the risk of contamination. We recommend Choi steel and/or paint coating for best results.

 

GMP Cleanroom Floors

 

(1) Cleanroom floors are required to be smooth and level, scratch resistant, impact resistant, easy to clean, high integrity, and free of cracks. In addition, GMP cleanroom floors must be anti-static and possess sufficient weight bearing capacity.

(2) Cleanroom floors must be moisture resistant. To achieve this, install a buffer layer below the concrete foundation layer and use an elevated floor.

(3) Approved floor surface coatings: a) Inelastic Surface - Terrazzo / b) Painted Surface (film) - acrylic, epoxy, polyurethane; self-leveling - self-leveling epoxy resin / c) Elastic Facing Material - PVC Plastic Flooring

 

 

GMP Cleanroom Doors And Windows

 

Doors used in cleanrooms must be smooth and even, easy to clean, of simple design (no door sill), and must open in the direction or the cleanest area that they connect. Cleanroom doors must be sealed when not in use to preserve the positive pressure environment. In order to avoid mold and deformation, wooden doors should never be used in clean areas or cleanrooms.

Windows in cleanrooms should be smooth and even, of simple design, resistant to dust collection, and installed flush with interior walls (no windowsill). Cleanroom windows should not be made of wood. Windows installed between clean areas and non-clean areas should consist of at least two layers, with at least one of those layers being a non-moveable pane.

 

GMP Cleanroom Requirements For Health Products

 

(1) An appropriate air quality and temperature control system must be installed according to the type of health product being manufactured and the proximate environment.

(2) The manufacture and packaging of pills, tablets, caplets, soft capsules, powders, medicinal teas, pastes and related products should abide by the guidelines set forth in GMP for D level cleanrooms. The manufacturer may further optimize the manufacturing and packaging environment and facilities depending on the exact nature of the product.

 

Level Of Airborne Particulate Cleanliness In Prefab Cleanrooms

 

Level Maximum Particles/m3 Equivalent 
  ≥0.1 μm ≥0.2 μm ≥0.3 μm ≥0.5 μm ≥1 μm ≥5 μm  
ISO 1 10b d d d d e  
ISO 2 100 24b 10b d d e  
ISO 3 1000 237 102 35b d e Class 1
ISO 4 10000 2370 1020 352 83b e Class 10
ISO 5 100000 23700 10200 3520 832 d,e,f Class 100
ISO 6 1000000 237000 102000 35200 8320 293 Class 1,000
ISO 7 c c c 352000 83200 2930 Class 10,000
ISO 8 c c c 3520000 832000 29300 Class 100,000
ISO 9 c c c 35200000 8320000 293000 Room Air

 

Specification Table

 

Area 15㎡ 30㎡ 50㎡ 100㎡
Material Aluminum frame/Baking steel plate/lnsulating glass window
FFU class 1-100 12pcs 24pcs 48pcs 96pcs
FFU class-1K 3pcs 6pcs 9pcs 18pcs
FFU class-10K 2pcs 4pcs 6pcs 12pcs
Speed (m/s) 0.45m/s ±20% 0.45m/s ±20%
Temperature (optional) 18-28°C
Humidity (opiional) 50-70% 50-70%
Illumination 400-800LUX
Power 2.4-7kw 4.8-10kw 9.6-19kw 19.2-30kw
 

 

Why Choose Us

 

Gcc is one of the leaders in modular cleanrooms industry that can provide you with the most cost-effective cleanroom solutions according to your require or give you professional advice.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2010

  • Total Annual:

    10000000-20000000

  • Employee Number:

    >100

  • Ecer Certification:

    Verified Supplier

Guangzhou Cleanroom Constuction Co., Ltd. was established in 2010 and is a high-quality enterprise in China's cleanroom system engineering and equipment manufacturing. The company has been recognized as a high-tech enterprise and a "little giant" of technological innovation in Guangzho... Guangzhou Cleanroom Constuction Co., Ltd. was established in 2010 and is a high-quality enterprise in China's cleanroom system engineering and equipment manufacturing. The company has been recognized as a high-tech enterprise and a "little giant" of technological innovation in Guangzho...

+ Read More

Get in touch with us

  • Reach Us
  • Guangzhou Cleanroom Construction Co., Ltd.
  • https://www.prefabcleanroom.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement