China factories

China factory - Hefei Coolnet power  Co., ltd

Hefei Coolnet power Co., ltd

  • China,Hefei ,Anhui
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China 80-100kW Fluorine Pump Precision Cooling System For Server Rooms And Data
China 80-100kW Fluorine Pump Precision Cooling System For Server Rooms And Data

  1. China 80-100kW Fluorine Pump Precision Cooling System For Server Rooms And Data
  2. China 80-100kW Fluorine Pump Precision Cooling System For Server Rooms And Data
  3. China 80-100kW Fluorine Pump Precision Cooling System For Server Rooms And Data
  4. China 80-100kW Fluorine Pump Precision Cooling System For Server Rooms And Data

80-100kW Fluorine Pump Precision Cooling System For Server Rooms And Data

  1. MOQ: 1
  2. Price: To be Negotiated
  3. Get Latest Price
Payment Terms T/T
Supply Ability 1000/Month
Delivery Time 4W
Packaging Details WOODEN
Total Capacity 30.6KW
Refrigerant R410A
Airflow 9200 m3/h
Mounting Floor Standing
Condition New
Voltage 380v/220v,220V/380V,380V/415V
Function Precision Air Conditioning
Application Computer Room,Data Center, Laboratories,Large Supermarket
Warranty 1 Year
After-sales Service provided Engineers Available to Service Machinery Overseas
Brand Name Coolent
Model Number CYA S30F
Certification ISO/CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 1000/Month
Delivery Time 4W Packaging Details WOODEN
Total Capacity 30.6KW Refrigerant R410A
Airflow 9200 m3/h Mounting Floor Standing
Condition New Voltage 380v/220v,220V/380V,380V/415V
Function Precision Air Conditioning Application Computer Room,Data Center, Laboratories,Large Supermarket
Warranty 1 Year After-sales Service provided Engineers Available to Service Machinery Overseas
Brand Name Coolent Model Number CYA S30F
Certification ISO/CE Place of Origin China
High Light Fluorine Pump Precision Cooling System100kW Fluorine Pump Precision Cooling SystemServer Rooms Fluorine Pump Air Conditioner

Coolnet Fluorine Pump Series Precision Air Cooling System for Data and Call Centers with Energy-Saving Technology

Products Introduction                                            

Coolnet fluorine pump series dual-cycle refrigerant system is a high-efficiency and energy-saving preciison air condioner. it provides precise temperature and humidity control for large and medium-size data rooms. Dual cycle system makes full use of outdoor natural cold sources and uses a set of refrigeraon systems to achieve three refrigeraon modes, It adopts high efficiency compressor and EC centrifugal fan to meet the requirements of 24 X 7 all weather connuous operaon.

 

Applications                                             

  • Computer room and data center
  • Switch room and mobile center station in telecommunication
  • High-tech environment and lab
  • Industrial automation control room and precision manufacturing workshop
  • Standard test room and calibration center
  • UPS and battery room
  • Test room in hospital
  • Biochemical culture chamber

 

Products Configuraons                            

Controller

7-inch color touch screen high-precision control, a variety of group control modes, to achieve 32 units group control, precise and reliable contro.

PTC Heater

PTC electric heang, aluminum alloy fins heat up quickly, can realize automac temperature adjustment and even heat generaon.

EC Fan

Energy-saving EC centrifugal fan, large air volume, high stac pressure, smooth operaon, low noise

Scroll Compressor

Stable design realizes high reliability and durability for easy repair and maintenance. Low noise, low vibra�on and high energy efficiency throughout the enre operang period.

Humidify System

Electrode humidificaon volume, high efficiency and with automac flushing function.

 

 

Advantages & Features                                          

  • Fluorine pump energy-saving dual-cycle air condioning technology leads the world
  • No fresh air circulaon system required, it will not affect the air quality in data center , without damage of the building appearance.
  • No Ethylene glycol , no worries about water polluon
  • Full use of natural cold sources, when ambinent temperature less than 25°C, the operaon of refrigerant pump can reduce the energy consumpon of the unit and have significant energy-saving effects.
  • AEER can reach 12
  • The indoor unit adopts high-performance EC fan
  • The evaporator adopts V-shaped design, with uniform return air and low resistance.
  • DC inverter compressor reduces energy consumpon

Technical Parameters                                                                                                                                                                                

Model CYA S30F S35F S40F S45F S50F T62F T72F T82F T92F T102F
Total Capacity(KW) 30.6 36 41 45.8 50.4 61.6 71.8 81.6 91 100.8
Sensible Capacity(KW) 27.6 32.4 36.9 41.3 45.9 55.4 65.3 73.4 87.2 90.7
Fan Section EC Fan
Fan Quantity 1 1 1 1 1 2 2 2 2 2
Air Flow (m³/h) 9200 10500 11500 12800 13500 18400 21000 23000 25600 27000
Excess Pressure Outside Pa Standard pressure is 20Pa, adjustable from 20~300Pa
Air Fiter G4
Compressor Scroll Compressors
Compressor Quantity 1 1 1 1 1 2 2 2 2 2
Refrigerant R410A
Electric Heating Type PTC Electrical Heating
Capacity(KW) 6 6 9 9 9 9 9 9 15 15
Rated Current(A) 10 10 14 14 14 14 14 14 23 23
Humidifier Section Electrode Steam Humidification
Capacity(kg/h) 5 5 8 8 8 13 13 13 13 13
Rated Current (A) 6 6 10 10 10 15 15 15 15 15
Power Supply 380v/50HZ 3N~
Full Loaded Circuit 41 47.2 53.9 60 61.6 77.5 89.8 100.4 115.4 118.6
Humidifier Inlet Pipe(in) G1/2"
Condensate Drainage DN(mm) 18
Gas Pipe (mm) 22
Liquid Pipe (mm) 15.88 15.88 15.88 19.05 19.05 15.88 15.88 15.88 19.05 19.05
Installation Parameters for Indoor Units
Dimension W*D*H (mm) 890*983*1975 1315*983*1975 1740*983*1975 2165*983*1975
Weight(kg) 366 368 453 468 485 652 655 708 716 735
Condenser
Model CY 0522 0582 0662 0742 0832 0522 0582 0662 0742 0832
Quantity 1 1 1 1 1 2 2 2 2 2
Pump Cabinet
Model CN-LAF 1 1 1 1 1 2 2 2 2 2
Dimension 460*220*660
Integrated Condenser with Pump
Outdoor Temperature 35°C CYP0441 CYP0551 CYP0551 CYP0661 CYP0771 CYP0882 CYP1102 CYP1102 CYP1322 CYP1542
Outdoor Temperature 45°C CYP0551 CYP0661 CYP0661 CYP0771 CYP0881 CYP1102 CYP1322 CYP1322 CYP1542 CYP1762
 

Certificates                                      

 

Factory Details                                         

Packing & Delivery                                              

 

Case                                         

 

 

 

 
 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2010

  • Total Annual:

    10,000,000.00-10,000,000.00

  • Employee Number:

    100~150

  • Ecer Certification:

    Verified Supplier

Coolnet focuses on the R&D, production and application of data center integrated solutions. It is a service provider in the field of information infrastructure construction, with technology, products and solutions, and is committed to providing customers with products and overall solutions in th... Coolnet focuses on the R&D, production and application of data center integrated solutions. It is a service provider in the field of information infrastructure construction, with technology, products and solutions, and is committed to providing customers with products and overall solutions in th...

+ Read More

Get in touch with us

  • Reach Us
  • Hefei Coolnet power Co., ltd
  • Room 303, 3rd Floor, Building C, Yingte Workshop, West Section of Yanglin Road, High-tech Zone Mechanical and Electrical Industrial Park, Hefei City Anhui Province
  • https://www.precisionacunits.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement