Payment Terms | T/T, L/C |
Supply Ability | 1000Unit/Month |
Delivery Time | 20-45 working days |
Packaging Details | Standard export package |
cooling capacity | 26-102KW |
Operating voltage | 380V 3Ph-50HZ |
Warranty | 1 Year |
Color | Customized colors |
Airflow | Upflow/Downflow |
Fan Section | Centrifugal EC FAN |
Compressor | Scroll compressor |
Mounting | Floor Standing |
Brand Name | Coolent |
Model Number | CYDS26D/U |
Certification | ISO/CE |
Place of Origin | China |
View Detail Information
Explore similar products
8KW Computer Room Air Conditioning Unit , Close Control Air Conditioning Unit
Computer Room Precision Data Center CRAC Unit 20kW
30kW Computer Room Air Conditioning Unit , IT Room Air Conditioner
25KW Computer Room Air Conditioning Unit For Data Center IDC Cooling System
Product Specification
Payment Terms | T/T, L/C | Supply Ability | 1000Unit/Month |
Delivery Time | 20-45 working days | Packaging Details | Standard export package |
cooling capacity | 26-102KW | Operating voltage | 380V 3Ph-50HZ |
Warranty | 1 Year | Color | Customized colors |
Airflow | Upflow/Downflow | Fan Section | Centrifugal EC FAN |
Compressor | Scroll compressor | Mounting | Floor Standing |
Brand Name | Coolent | Model Number | CYDS26D/U |
Certification | ISO/CE | Place of Origin | China |
High Light | Single Cooling Precision AC Unit ,Computer Room Precision AC Unit ,Electric Heating Precision AC Unit |
Intelligent Single Cooling Electric Heating Precision Air Conditioner Computer Room AC
Product Introduction
Cyber Master series of medium and large air-cooled room air conditioners cover 26kW~102kW, with R410a refrigerant as the refrigerant of choice. The heat exchange module, air supply module and control module are independent, so that maintenance work can be carried out without stopping. The sunken structure can realize the horizontal air supply under the floor, and the resistance loss is smaller.
Advantages
| |
Technical Features |
![]() | Fan Use the efficient and low-noise EBM backward tilt centrifugal wind motorized balance test to ensure long life, high energy efficiency, low energy consumption and low noise operation. Compared with equipment with the same air volume in the industry, the power consumption is the lowest.
Condenser The air-cooled condenser is made of marine grade corrosion-resistant materials, has outstanding rigidity and anti-corrosion functions, and is accustomed to various environmental conditions. Fully adjustable speed electric fans are used to achieve energy saving and low noise.
Air pressure switch Configurable filter blockage and airflow loss are two functions of the air pressure switch for accurate monitoring of filter status and fan status to ensure normal operation of the unit.
Humidifier Electrode humidifier with high efficiency and large humidification, automatic flushing.
Compressor Copeland flexible scroll compressor with high efficiency, optional Danfoss EC compressor, which can regulate cooling capacity from 10% to 100%, can dynamically output cooling capacity according to demand, energy saving,and high efficiency. |
Technical Parameters |
Model: CYD | S26D/U | S31D/U | S35D/U | S40D/U | S45D/U | T41D/U | T50D/U | T55D/U | T61D/U | T70D/U | T85D/U | T90D/U | T100D/U | ||
Power Supply | 380V 3Ph-50HZ | ||||||||||||||
Air Discharge | Upflow/Downflow | ||||||||||||||
Cooling Capacity :24℃/50%RH | |||||||||||||||
DX | Total Capacity | KW | 26.8 | 31.5 | 35.5 | 40.2 | 45.6 | 41.9 | 50.5 | 55.4 | 61.4 | 70.5 | 85.5 | 90.8 | 102 |
Sensible | KW | 24.2 | 28.9 | 33.2 | 37.6 | 42.2 | 38.8 | 47.8 | 51.6 | 57.5 | 65.2 | 79.5 | 84.5 | 95.7 | |
AEER | W/W | 3.6 | 3.7 | 3.7 | 3.7 | 3.6 | 3.6 | 3.7 | 3.7 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | |
CW | water inlet/outlet | T7/12℃ | |||||||||||||
Total Capacity | KW | 33.6 | 33.6 | 44.2 | 44.2 | 56.4 | 44.2 | 56.4 | 59.1 | 73.5 | 76.4 | 89.2 | 92.5 | 92.5 | |
Sensible | KW | 29.2 | 29.2 | 37.7 | 37.7 | 48.6 | 37.7 | 48.6 | 51.2 | 63.2 | 66 | 77.8 | 81.7 | 81.7 | |
Flow Rate | m3/h | 5.8 | 5.8 | 7.6 | 7.6 | 9.7 | 7.6 | 9.7 | 10.1 | 12.6 | 13.1 | 15.3 | 15.9 | 15.9 | |
Compressor | Hermetic scroll | ||||||||||||||
Refrigerant | R410A | ||||||||||||||
Compressor quantity | PC | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | |
Fan Section | Centrifugal EC fan | ||||||||||||||
Airflow | m3/h | 7800 | 9200 | 9800 | 10600 | 12000 | 11500 | 15500 | 16000 | 17500 | 18500 | 22500 | 23500 | 24200 | |
Fan quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | |
Rated current | A | 2.8 | 3.5 | 4.1 | 4.4 | 4.9 | 4.4 | 4.4 | 5 | 5.2 | 5.2 | 16.5 | 16.5 | 16.5 | |
Rated power | W | 1200 | 1320 | 2000 | 2150 | 2400 | 1800 | 2000 | 3000 | 3300 | 3900 | 5400 | 6300 | 6300 | |
Excess press outside(2) | Pa | 20-300 Adjustable | |||||||||||||
Air filter | Standard EN799 | ||||||||||||||
Level | ≥G4 | ||||||||||||||
Dust interception rate | >95% | ||||||||||||||
Fire resistance level | 1 | ||||||||||||||
Reheat Section | |||||||||||||||
Total heating capacity | KW | 6 | 6 | 6 | 9 | 9 | 9 | 9 | 9 | 9 | 9 | 15 | 15 | 15 | |
Material | PTC | ||||||||||||||
Humidifier Section | Electrode type | ||||||||||||||
Capacity | Kg/h | 5 | 5 | 5 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | |
Physical | |||||||||||||||
Length | mm | 915 | 915 | 915 | 1315 | 1315 | 1315 | 1315 | 1315 | 1790 | 1790 | 2190 | 2190 | 2190 | |
Depth | mm | 980 | 980 | 980 | 980 | 980 | 980 | 980 | 980 | 980 | 980 | 980 | 980 | 980 | |
Height | mm | 1975 | 1975 | 1975 | 1975 | 1975 | 1975 | 1975 | 1975 | 1975 | 1975 | 1975 | 1975 | 1975 | |
Weight | KG | 393 | 490 | 590 | 595 | 610 | 605 | 615 | 620 | 625 | 625 | 985 | 992 | 1015 | |
Connection Pipe Size | |||||||||||||||
Liquid pipe | mm | 22 | 22 | 28 | 28 | 28 | 22 | 22 | 22 | 22 | 28 | 28 | 28 | 28 | |
Gas Pipe | mm | 28 | 28 | 35 | 35 | 35 | 28 | 28 | 28 | 28 | 35 | 35 | 35 | 35 | |
Inlet Pipe of Humidifier(Female) | G1/2'' | G1/2'' | G1/2'' | G1/2'' | G1/2'' | G1/2'' | G1/2'' | G1/2'' | G1/2'' | G1/2'' | G1/2'' | G1/2'' | G1/2'' | ||
Drain Pipe-ID | mm | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | |
Breakers & Cables | |||||||||||||||
Recommended Breaker (Indoor Unit) | A | 50 | 50 | 63 | 80 | 80 | 80 | 80 | 100 | 100 | 125 | 150 | 150 | 150 | |
Cableds (Indoor Unit) | mm2 | 4*10+1*6 | 4*10+1*6 | 4*10+1*6 | 4*10 | 4*16+1*10 | 4*16+1*10 | 4*16+1*10 | 4*16+1*10 | 4*16+1*10 | 3*25+2*16 | 3*25+2*16 | 3*50+2*25 | 3*50+2*25 | |
Condenser Model | mm2 | 451 | 522 | 582 | 662 | 742 | 2*0351 | 2*0451 | 2*0451 | 2*0522 | 2*0582 | 2*0662 | 2*0742 | 2*0832 |
Certificates |
Packing & Delivery |
Company Details
Business Type:
Manufacturer
Year Established:
2010
Total Annual:
10,000,000.00-10,000,000.00
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Coolnet focuses on the R&D, production and application of data center integrated solutions. It is a service provider in the field of information infrastructure construction, with technology, products and solutions, and is committed to providing customers with products and overall solutions in th... Coolnet focuses on the R&D, production and application of data center integrated solutions. It is a service provider in the field of information infrastructure construction, with technology, products and solutions, and is committed to providing customers with products and overall solutions in th...