China 0.005 Class CT PT Test Equipment Integrated With Source
China 0.005 Class CT PT Test Equipment Integrated With Source

  1. China 0.005 Class CT PT Test Equipment Integrated With Source

0.005 Class CT PT Test Equipment Integrated With Source

  1. MOQ: 1
  2. Price: Negotiable
  3. Get Latest Price
Supply Ability 20 sets per month
Delivery Time 30-45 days
Packaging Details Wooden Package
Accuracy Class 0.005
Current 5 to 3200A
Rated Secondary 1A, 5A
Frequency 50/60HZ
Power factor 1.0
Weight approx 50kgs
Brand Name HNMC
Model Number HLB-32G
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 20 sets per month Delivery Time 30-45 days
Packaging Details Wooden Package Accuracy Class 0.005
Current 5 to 3200A Rated Secondary 1A, 5A
Frequency 50/60HZ Power factor 1.0
Weight approx 50kgs Brand Name HNMC
Model Number HLB-32G Place of Origin China
High Light 0.005 Class CT PT Test Equipment5A CT PT Test Equipment140mm current transformer ratio test

Standard Current Transformer HLB-32G series

 

Technical Parameter

Primary
Wound primary winding 5….100A or 5….480A, 50/60HZ (more option available)
Applied primary

Applied primary: 100….3200A (1…10, maximum 12

turns) or 480A-3200A (1-2 turns) (more option available)

Rated Secondary

1A (model No.HLB-32G/1), 5A (model No.HLB-32G/5)

Or 1A&5A combined (model No.HLB-32G/1-5)

Test Primary A 2000 ampere-turn winding provided for self test of CT
Accuracy 0.005%(or 0.002% as option)
Duty cycle Continuous upto 3200A, and 30 minutes or more at 4000A
Secondary winding design 8Taps at 0, 100, 200, 1500, 1600, 2000, 2500, 3200 amperes to turns
Ratios available with customer applied primary winding 100, 120, 125, 130, 140, 150, 160, 175, 180, 200, 225, 240, 250, 260, 280, 300, 320, 325, 350, 360, 375, 400, 450, 480, 500, 600, 625, 640, 650, 700, 750, 800, 900, 1000, 1200, 1250,1300, 1400, 1500, 1600, 1800, 2000, 2400, 2500, 3000, 3200A
Ratio available with pre-wound primary winding 100, 90, 80, 75, 70, 65, 62.5, 60, 50, 45, 40, 37.5, 35, 32.5, 31.25,30,25, 24, 20, 18, 16, 15, 14,13,12.5, 12, 10, 9, 8, 7.5, 7, 6.5, 6.25, 6, 5, 4.5, 4, 3.75, 3.5, 3.25, 3.125, 3, 2.5
Rated secondary burden

5VA (model No.HLB-32G/5)

0.2VA (model No.HLB-32G/1)

5VA at I2 = 5A, Burden is 0.2VA at I2 = 1A (model No.HLB-32G/1-5)

Power factor COSΦ=1.0
Operating range (1%-120%)In
Frequency 50/60HZ
Voltage level AC 600V
Withstand voltage 2000V 1min
Insulating medium air
Dimension of feed through hole

Φ140mm

 

Size

Smaller one: Approx 590mm*400mm*240mm (design with applied primary 1-10, maximum 12 turns)

Bigger one: Approx 590mm*400mm*600mm (design with applied primary 1-2 turns)

Weight approx 50kgs
Accessories 3.5meters length secondary cable with connectors

 

 

 Designs for optional

 

Features

 

1) More ratios to ensure good accuracy

2) 5 to 3200A current transformer design

3) Used for precision measurement of AC current or calibration of instrument current transformer

4) Can be installed on a bus bar can be used with a primary conductor consisting of turn numbers

5) Designed with a tapped primary & secondary windings to ensure a large number of ratios over

    a range 5 to 3200A (or more as option)

6) Adopting “two stage principles” to ensure excellent accuracy and also allow to run long leads between

    CT and load but not degrading CT accuracy.

7) Adopting advanced design technology to ensure that it can be used in severe magnetic environment

    and also not affected by position of primary conductor in the hole or in the location of return conductor

8) With facility to test the performance of CT and verify its own accuracy.

9) CT ratio selection switch is optional and if customer need, it can be provided by adjust the design structure,

    then can select mentioned CT ratios but no need changing secondary.

 

 

Note:

 

1) Also can offer standard current transformer integrated with source (3200A CT with 4000A & 8.8KVA source;

    2000A CT with 2400A & 8.8KVA source)

2) Photo design mentioned in the brochure is as a reference, final design possibly will have change after

    customer inform special & optional requirements.

3) If choosing bigger one design, customer can reduce a lot of time when applying turns.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Seller

  • Year Established:

    2009

  • Total Annual:

    100-500

  • Employee Number:

    8 ~10

  • Ecer Certification:

    Active Member

Zhengzhou Great Electric Co.,Ltd, established in 2011, is a fast growing company in Zhengzhou, Henan Province, in the same year, Henan Muchen Trading Co.,Ltd was founded as our export sales company, taking charge of all export deals. We specialize in production & supply of high-quality produc... Zhengzhou Great Electric Co.,Ltd, established in 2011, is a fast growing company in Zhengzhou, Henan Province, in the same year, Henan Muchen Trading Co.,Ltd was founded as our export sales company, taking charge of all export deals. We specialize in production & supply of high-quality produc...

+ Read More

Get in touch with us

  • Reach Us
  • Zhengzhou Great Electric Co.,Ltd.
  • No.1207-1, Building #1, the National University Sci-Tech Park of Henan Province, No.11 Changchun Road, Zhengzhou, Henan 450000
  • https://www.powertest-equipment.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement