China High And Low Voltage Electrical Surge Protection Devices 385V 20KA High
China High And Low Voltage Electrical Surge Protection Devices 385V 20KA High

  1. China High And Low Voltage Electrical Surge Protection Devices 385V 20KA High

High And Low Voltage Electrical Surge Protection Devices 385V 20KA High

  1. MOQ: 1 piece
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms L/C, T/T, Western Union, MoneyGram
Supply Ability 20000 pieces/month
Delivery Time 3-7 work day
Packaging Details Carton packaging
Product name Surge protector
UC 385V
IN 10KA
IMAX 20KA
Standard IEC/EN 61643-11
Certificate CE
Warranty 2 Years
OEM/ODM YES
Brand Name THOR
Model Number TRS4-D20
Certification CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T, Western Union, MoneyGram Supply Ability 20000 pieces/month
Delivery Time 3-7 work day Packaging Details Carton packaging
Product name Surge protector UC 385V
IN 10KA IMAX 20KA
Standard IEC/EN 61643-11 Certificate CE
Warranty 2 Years OEM/ODM YES
Brand Name THOR Model Number TRS4-D20
Certification CE Place of Origin CHINA
High Light industrial surge suppressorvoltage spike protection device

Surge protector 3P40KA 385KV high and low voltage cabinet lightning protection module arrester

 

Working principle of product


   Under normal working condition, the lightning protection module is in a high resistance state. When the power supply line has lightning invasion or operation transient overvoltage, the lightning protection module will immediately pass through the response speed of nanosecond level, and limit the lightning overvoltage or transient overvoltage to the voltage range allowed by the electrical equipment, thus protecting the normal operation of the electronic equipment. After that, the lightning protection module quickly returns to the high impedance state without affecting the normal power supply of the grid.

 

 

 

Product specification

 

  1. Rated Operating Voitage(UC):275V

 

  2. Rated Operating Voltage(UN):220V

 

  3. Voltage protective level(UP):1.5KV

 

  4. Max discharge current(IMAX):20KA

 

  5. Nominal discharge current(IN):10KA

 

  6. Ressponse time(NS):<25

 

  7. Ingress Protection Rating:IP20

 

 

 

Product features


  1. traffic flow to further improve safety


  2. core components are strictly screened, stable performance and reliable operation.


  3. using the latest arc extinguishing technology to avoid fire completely 

 

  4. module is designed and installed conveniently and can be replaced directly.

 

 

 


Notice of product


  1. connect the grounding wire of the lightning protector with the ground wire of the lightning protection system.


  2. it should match the working voltage of the protected equipment. Please install according to the installation sketch.


  3. lightning protection device IN as input and OUT as output, the input end is connected with the outside, and the output end of the input end of the connecting device is protected


  4. The PE line of the  lightning arrester must be reliably connected with the ground wire of the lightning protection system, and the connection line is short, thick and straight.

 

 

 

Brief introduction

 

   Surge protector is the lightning protection measures adopted by Zhejiang toer Electric Co., Ltd. for the electrical system, which is applied to the power protection of equipment system in high lightning risk area. It can prevent all kinds of surge currents directly hitting lightning. Avoid the damage of lightning surge to other devices in the loop.

 

 

 

Product Installation

 

With 35mm standard DIN-rail mounting, connecting copper stranded conductor is 2.5~35mm²

At front of spd each pole must be setted protection---used fuse or miniature circuit breaker lightning current SPD protection,after SPD breakdown to short circuit protection.

SPD install on protected line(equipment) to the front and connected to the supply line. A class products install in the building home-entry line hold larger surge current total distribution box. B, C class products most install on the floor distribution box, D class products close to the front-end equipment that smaller surge current, smaller residual voltage place.

 

 

 


Company profile

 

   Incorporated in 2006, Zhejiang Thor Electric Co., Ltd has built everything to offer a wide range of innovative and reliable surge protection solutions and products.

 

 

 

Product packaging:Carton packing

 

Transportation method

  1. Express company: FEDEX,UPS,DHL,TNT

    2. Trains, ships, aircraft transport

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company

  • Year Established:

    2006

  • Total Annual:

    100-150

  • Employee Number:

    300~500

  • Ecer Certification:

    Active Member

Thor is all about protecting against the damaging effects of power transients. It is our goal and mission to connect our customer challenges with high-quality, right-priced solutions and products – completed by unrivaled customer service and technical support. Incorporated in 2006, Zhejiang... Thor is all about protecting against the damaging effects of power transients. It is our goal and mission to connect our customer challenges with high-quality, right-priced solutions and products – completed by unrivaled customer service and technical support. Incorporated in 2006, Zhejiang...

+ Read More

Get in touch with us

  • Reach Us
  • Zhejiang THOR Electric Co., Ltd
  • China Zhejiang Wenzhou Economic Development Zone
  • http://www.powersurgeprotectiondevice.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement