Payment Terms | L/C, T/T, Western Union, MoneyGram |
Supply Ability | 20000 pieces/month |
Delivery Time | 3-7 work day |
Packaging Details | Carton packaging |
Product name | Surge protector |
UC | 385V |
IN | 20KA |
IMAX | 40KA |
Standard | IEC/EN 61643-11 |
Certificate | CE |
Warranty | 2 Years |
OEM/ODM | YES |
Brand Name | THOR |
Model Number | TRS4-C40 |
Certification | CE |
Place of Origin | CHINA |
View Detail Information
Explore similar products
Indoor Mounted Spd Surge Protection Device , Mains Surge Protection Devices
Household Appliances Surge Suppression Devices , 220V / 480v Surge Protection
40KA - 80KA Electrical Surge Protection Devices Against Lightning Fluctuations
SPD Industrial Surge Protection Devices , Remote Signal Function Voltage Spike
Product Specification
Payment Terms | L/C, T/T, Western Union, MoneyGram | Supply Ability | 20000 pieces/month |
Delivery Time | 3-7 work day | Packaging Details | Carton packaging |
Product name | Surge protector | UC | 385V |
IN | 20KA | IMAX | 40KA |
Standard | IEC/EN 61643-11 | Certificate | CE |
Warranty | 2 Years | OEM/ODM | YES |
Brand Name | THOR | Model Number | TRS4-C40 |
Certification | CE | Place of Origin | CHINA |
High Light | industrial surge suppressor ,industrial surge protection devices |
3P lightning protector TRS4-C40 40KA voltage 385v DC surge
Brief introduction
The surge protector is a lightning protection measure adopted by Zhejiang toer Electric Co., Ltd. for the electrical system. It is a protective device for lightning protection and pressure protection in household, third industry and industrial fields.
It is mainly used to limit overvoltage and discharge electric current. Surge protector is usually connected with protected equipment. When overvoltage is generated, it can play the role of shunting and voltage limiting. To prevent excessive current and voltage damage to equipment, play the role of protection devices.
Working principle of product
In the equipment system, the inductive or capacitive coupling voltage is caused by the lightning shock and the switching operation of the upstream power supply system. Therefore, the surge may damage the photovoltaic modules and inverters and other devices. This will cause serious consequences for the operation of the system. The surge protector is a DC power defense specially designed for this purpose. The lightning module, once the high voltage, and endanger the insulation of the protected equipment, the lightning arrester acts immediately, the high voltage impact current guide the earth, thus limiting the voltage amplitude, protecting the insulation of the equipment. When the overvoltage is gone, the arrester is restored to its original state quickly, so as to protect the power equipment.
Product specification
Model and specofocation | TRS4-D20 | TRS4-C40 | TRS4-B60 | ||||
Rated Operating Voltage | Un | 220V/380V | |||||
Max continuous operating voltage | Uc | 385V AC | |||||
Voltage protective level | Up(KV)≤ | 1.5 | 1.8 | 2.0 | |||
Max discharge current | Imax(8/20μS) | 20kA | 40kA | 60kA | |||
Nominal discharge current | In(8/20μS) | 10kA | 20kA | 30kA | |||
Response time | ns | 〈25 | |||||
Ingress Protection Rating
|
IP20 | ||||||
Indication of invalidation | Aging invalidation:green Normal,red:Invaldation | ||||||
Configuration dimension | Three-phase four-wire:72×62×90 | ||||||
Application | Primary protection for in line | ||||||
Operating condition | Temp:-40℃~+70℃ | ||||||
RH≤95%(25℃) | |||||||
Sea level elevation≤3km | |||||||
Remote signal function | Can also picking | ||||||
Remarks | Other max continuous operating voltage can be customized |
Product features
1. tunnel type terminal connection, tighter wiring is more compact.
2. cut off the line when undervoltage occurs, and reset automatically after restoration.
3. fastening slideway buckle design is very difficult to fall off
4. detachable assembly and pluggable convenience
Notice of product
1. it should match the working voltage of the protected equipment. Please install according to the installation sketch.
2. lightning protector's input port (IN) is connected to the signal channel, and the output terminal (OUT) is connected with the input end of the protected device, so it can't connect with the signal.
3. when installing, pay attention to the cable entering and leaving the surge protector. The cables should be separated to avoid the two coupling of surge.
4. generally speaking, it is better to separate the protected conductor from the non protected conductor, and it should be separated from the ground wire. At the same time, in order to avoid transient orthogonal coupling between power cables and communication cables, necessary measurements should be made.
Company profile
Zhejiang Thor Electric Co., Ltd is committed to meeting the requirements of the European Union’s Waste Electrical and Electronic Equipment (WEEE) directive. This directive requires producers of electrical and electronic equipment to finance the take-back for re-use or recycling of their products placed on the EU market after 2005.
Product packaging:Carton packing
Transportation method
1. Express company: FEDEX,UPS,DHL,TNT
2. Trains, ships, aircraft transport
Company Details
Business Type:
Manufacturer,Exporter,Trading Company
Year Established:
2006
Total Annual:
100-150
Employee Number:
300~500
Ecer Certification:
Active Member
Thor is all about protecting against the damaging effects of power transients. It is our goal and mission to connect our customer challenges with high-quality, right-priced solutions and products – completed by unrivaled customer service and technical support. Incorporated in 2006, Zhejiang... Thor is all about protecting against the damaging effects of power transients. It is our goal and mission to connect our customer challenges with high-quality, right-priced solutions and products – completed by unrivaled customer service and technical support. Incorporated in 2006, Zhejiang...
Get in touch with us
Leave a Message, we will call you back quickly!