Standard RJ45 Interface Surge Suppression Devices , 220V Lightning Surge

  1. MOQ: 1 piece
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms L/C, T/T, Western Union, MoneyGram
Supply Ability 20000 pieces/month
Delivery Time 3-7 work day
Packaging Details Carton packaging
Product name Surge protector
UC 385V
IN 20KA
IMAX 40KA
Standard IEC/EN 61643-11
Certificate CE
Warranty 2 Years
OEM/ODM YES
Brand Name THOR
Model Number TRS4-C40
Certification CE
Place of Origin CHINA

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T, Western Union, MoneyGram Supply Ability 20000 pieces/month
Delivery Time 3-7 work day Packaging Details Carton packaging
Product name Surge protector UC 385V
IN 20KA IMAX 40KA
Standard IEC/EN 61643-11 Certificate CE
Warranty 2 Years OEM/ODM YES
Brand Name THOR Model Number TRS4-C40
Certification CE Place of Origin CHINA
High Light industrial surge protection devicesvoltage spike protection device

2p surge protection switch SPD TRS4-C40 lightning protection lightning arrester switch 220V

 

Working principle of product


   Under normal working condition, the lightning protection module is in a high resistance state. When the power supply line has lightning invasion or operation transient overvoltage, the lightning protection module will immediately pass through the response speed of nanosecond level, and limit the lightning overvoltage or transient overvoltage to the voltage range allowed by the electrical equipment, thus protecting the normal operation of the electronic equipment. After that, the lightning protection module quickly returns to the high impedance state without affecting the normal power supply of the grid.

 


Product specification

 

Model and specofocation   TRS4-D20 TRS4-C40 TRS4-B60
Rated Operating Voltage Un 220V/380V
Max continuous operating voltage Uc 385V AC
Voltage protective level Up(KV)≤ 1.5 1.8 2.0
Max discharge current Imax(8/20μS) 20kA 40kA 60kA
Nominal discharge current In(8/20μS) 10kA 20kA 30kA
Response time ns 〈25
Ingress Protection Rating
  IP20
Indication of invalidation   Aging invalidation:green Normal,red:Invaldation
Configuration dimension   Three-phase four-wire:72×62×90
Application   Primary protection for in line
Operating condition   Temp:-40℃~+70℃
  RH≤95%(25℃)
  Sea level elevation≤3km
Remote signal function   Can also picking
Remarks   Other max continuous operating voltage can be customized
 

 

 

 

Brief introduction


   Surge protector is the lightning protection measures taken by Zhejiang toer Electric Co., Ltd. for the electrical system. It protects the sensitive lines from the damage caused by lightning induction voltage, power interference, electrostatic discharge and so on.
   The housing is installed on the 35mm electric rail, and it can be applied to single-phase and three-phase power supply lines and modular design through different combinations.

 

 

 

Product features


  1. copper fittings have good electrical conductivity


  2. can withstand high lightning shock


  3. high-performance chips can react quickly when problems arise.


  4. cut off the line when undervoltage occurs, and reset automatically after restoration.

 

 


Notice of product


  1. standard RJ45 interface can be conveniently connected to the front end of the protected equipment. The grounding path should be as short as possible, and the length should not exceed 1.5 meters.


  2. connect the grounding wire of the lightning protector with the ground wire of the lightning protection system.


  3. it should match the working voltage of the protected equipment. Please install according to the installation sketch.


  4. ambient air temperature is no more than +40 C and no less than -5 C, and the average value of 24 hours is no more than +35 C.

 

 


Company profile

   
  Thor has been designing new products to meet the RoHS directive since 2006. Thor’s ongoing commitment to RoHS compliance includes continuing efforts to reduce the presence of hazardous substances in the design and manufacture of a growing number of popular products.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company

  • Year Established:

    2006

  • Total Annual:

    100-150

  • Employee Number:

    300~500

  • Ecer Certification:

    Active Member

Thor is all about protecting against the damaging effects of power transients. It is our goal and mission to connect our customer challenges with high-quality, right-priced solutions and products – completed by unrivaled customer service and technical support. Incorporated in 2006, Zhejiang... Thor is all about protecting against the damaging effects of power transients. It is our goal and mission to connect our customer challenges with high-quality, right-priced solutions and products – completed by unrivaled customer service and technical support. Incorporated in 2006, Zhejiang...

+ Read More

Get in touch with us

  • Reach Us
  • Zhejiang THOR Electric Co., Ltd
  • China Zhejiang Wenzhou Economic Development Zone
  • http://www.powersurgeprotectiondevice.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement