Payment Terms | L/C, T/T, Western Union, MoneyGram |
Supply Ability | 20000 pieces/month |
Delivery Time | 3-7 work day |
Packaging Details | Carton packaging |
Product name | Surge protective device |
UCPV | 500V |
IN | 20KA |
IMAX | 40KA |
Standard | IEC/EN 61643-11 |
Certificate | CE |
Warranty | 2 Years |
OEM/ODM | YES |
Brand Name | THOR |
Model Number | TRS3-C40 |
Certification | CE |
Place of Origin | CHINA |
View Detail Information
Explore similar products
High Standard Solar Surge Protection Device UC 1000V 20KA - 40KA Flame Retardant
Surge protector solar 500V pv surge arrester solar SPD 40 KA dc surge protector
Photovoltaic Under Voltage Protection Device , Three Phase Electrical Surge
DC surge protection outdoor 600v solar surge protection device dc surge arrester
Product Specification
Payment Terms | L/C, T/T, Western Union, MoneyGram | Supply Ability | 20000 pieces/month |
Delivery Time | 3-7 work day | Packaging Details | Carton packaging |
Product name | Surge protective device | UCPV | 500V |
IN | 20KA | IMAX | 40KA |
Standard | IEC/EN 61643-11 | Certificate | CE |
Warranty | 2 Years | OEM/ODM | YES |
Brand Name | THOR | Model Number | TRS3-C40 |
Certification | CE | Place of Origin | CHINA |
High Light | dc surge protection device ,power supply surge protector |
photovoltaic DC surge protection, solar power lightning protection device, thunderstorm days can also be used safely.
Working principle of product
In the solar photovoltaic system, the inductive or capacitive coupling voltage is caused by the lightning shock and the switching operation of the upstream power supply system. Therefore, the surge may damage the photovoltaic modules and inverters, which will cause serious consequences for the operation of the photovoltaic system. The photovoltaic lightning arrester is specially developed for this purpose. The lightning protection module of the DC power supply, once the high voltage, and endanger the insulation of the protected equipment, the lightning arrester acts immediately, and the high voltage impact current is directed to the earth, thus limiting the amplitude of the voltage and protecting the insulation of the equipment. When the overvoltage is gone, the arrester is restored to its original state quickly, so as to protect the power equipment.
Product features
1. the protection flow is large, the residual pressure is very low, and the response time is fast.
2. adopt the latest arc extinguishing technology to avoid fire.
3. The thermal protection circuit is adopted, and the thermal protection is built.
4. with the power status indication, it indicates the working state of surge protector.
Product specification
Model | RTS3-C40 | |||
Rated Operating Voitage | UC | 500 | 800 | 1000 |
Voltage protective level | Up(KV)≤ | 1.8 | 3.0 | 3.6 |
Max discharge current | Imax(8/20μS) | 40 | ||
Nominal discharge current
|
In(8/20μS) | 20 | ||
Ressponse time | NS | <25 | ||
Lndication of invalidation | Aging invalidation:green Normal,red:Invaldation | |||
Operating condition | Temp:-40℃~+70℃ | |||
RH≤95%(25℃) | ||||
Sea level elevation≤3km | ||||
Remote signal function
|
Can also picking | |||
Remarks | Other max continuous operating voltage can be customized |
Product Details
Photovoltaic DC surge protector tor Electric Co., Ltd. is designed according to the relevant standards and applied to the lightning protection products of solar photovoltaic system. It has high lightning discharge capability, and the maximum discharge current of each module reaches 10KA. The product is standard 35mm guide rail installation, easy installation, single module can be inserted and replaced. According to different DC power sources, various specifications can be selected, which can be applied to multi-channel DC power supply system through different combinations.
Use of attention
1. connect the positive and negative pole and the ground wire to the positive and negative poles and the earth terminals of the lightning protector respectively, and screw the terminals. Connect the grounding wire and the lightning protection system reliably. When the wiring is completed, check the wiring is correct and firm, then switch on the power supply and put it into operation. Before installing the lightning protection module, we must cut off the power supply, and no live operation is strictly prohibited.
2. it is recommended to fuse fuse or automatic circuit breaker at the front end of DC power supply lightning protection module.
3. this product does not need special maintenance at ordinary times. It only needs to check regularly whether the connection is loose and whether the working state is normal.
Company profile
Thor is all about protecting against the damaging effects of power transients. It is our goal and mission to connect our customer challenges with high-quality, right-priced solutions and products – completed by unrivaled customer service and technical support.
Incorporated in 2006, Zhejiang Thor Electric Co., Ltd has built everything to offer a wide range of innovative and reliable surge protection solutions and products.
Company Details
Business Type:
Manufacturer,Exporter,Trading Company
Year Established:
2006
Total Annual:
100-150
Employee Number:
300~500
Ecer Certification:
Active Member
Thor is all about protecting against the damaging effects of power transients. It is our goal and mission to connect our customer challenges with high-quality, right-priced solutions and products – completed by unrivaled customer service and technical support. Incorporated in 2006, Zhejiang... Thor is all about protecting against the damaging effects of power transients. It is our goal and mission to connect our customer challenges with high-quality, right-priced solutions and products – completed by unrivaled customer service and technical support. Incorporated in 2006, Zhejiang...
Get in touch with us
Leave a Message, we will call you back quickly!