China Intelligent Underground Cable Fault Indicators Current Automatically For Short
China Intelligent Underground Cable Fault Indicators Current Automatically For Short

  1. China Intelligent Underground Cable Fault Indicators Current Automatically For Short
  2. China Intelligent Underground Cable Fault Indicators Current Automatically For Short

Intelligent Underground Cable Fault Indicators Current Automatically For Short

  1. MOQ: 1set(3pcs)
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms Western Union, L/C
Supply Ability 3000sets per week
Packaging Details 56*40*34cm,48 pcs /box ,standarad export box
line load current detected automatically
Inhibiting the switch-off surge current automatically
Function detect short circuit
optical fiber communication distance less than 10m
Brand Name Tianyihongda
Model Number TYHD-3
Certification type test report
Place of Origin Beijing,China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms Western Union, L/C Supply Ability 3000sets per week
Packaging Details 56*40*34cm,48 pcs /box ,standarad export box line load current detected automatically
Inhibiting the switch-off surge current automatically Function detect short circuit
optical fiber communication distance less than 10m Brand Name Tianyihongda
Model Number TYHD-3 Certification type test report
Place of Origin Beijing,China
High Light underground cable fault distance locatorunderground electric cable fault locator

The TYHD-3 cable indicator is suitable for the cable 35kV system (including bellow 35kV system).It can only judge short-circuit, without locally indicating function. When short-circuit happened in cable,It can help line finder find the fault quickly .shorten power-off duration,improve the reliability of power supply,The picture of product is below:

Working principle:

Using clip-on line structure of fault detector as sensor of measuring load current. The intelligent controller control as the core with little power consumption ,When a circuit has a short circuit fault,The fault detector automatically recognize fault current characteristics to judge intelligently. In the meantime. the action signal will be transmitted to the panel indicator installed locally by fiber and locally indicating,then the panel indicator send the wireless signal to DTU to realize the remote transmission of fault signal.

Installing methods:

Clip the indicator on the line as shown in the pictures1.2.3, rotate the screws clockwise to fix it and tighten the fault detector, connect the fault detector and panel indicator through short-distance plastics optical fiber; make sure to insert the optical fiber to the other end and tighten the nut. The length of the optical fiber should be less than 10m,The shorter the distance ,the higher the reliability .optical fiber cross-section is cut flat with a paper cutter, which is beneficial to the transmission of fiber signal

After the test completely cover the rubber cover,in order to avoid abnormal indicator accused by long-term light leakage

Function:

1) Install and disassemble easily, be suitable for Cable lines with an external diameter of less than 40 mm.

2 ) detect short circuit

3 ) epoxy resin pouring,whole-sealed structure, suitable to run outdoors for a long time.

4) The line load current can be detected automatically, no need to configure alarm parameters.

5) Inhibiting the switch-off surge current automatically.

6) Fiber data communication:

Indicating locally the fault alarm signal transmitting from fault indicator to panel indicator(if no panel indicator, this function is not available).

7) Taking electricity from cable current, equipped with built-in storage lithium battery, life is more than 15 years.

There is type test report for it, test items as following:

 

 

 

 

Type Test Items

 

1. appearance and structure 2.function 3. electrical device performance 4.low temperature performance 5.high temperature performance 6.alternating temperature humidity7.vibrationendurance 8.incline drop test 9. electrical device life 10. static electricity and elecro-discharge immunity test 11.radio frequency electromagnetic field radiated immunity test 12.surge impact immunity test 13. power frequency magnetic field immunity test. 14. Adjacent interference test 15.short-circuit withstand impact test 16. fire hazard test 17. power consumption test 18. protection grade test 19. gripping strength test of grip structure.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2014

  • Total Annual:

    3000000-5000000

  • Employee Number:

    150~180

  • Ecer Certification:

    Site Member

Beijing TIANYIHONGDA Science & Technology Development Co., LTD is located in Lize Business Circle area, a prosperous business area in the center of Beijing City, China. is a high and advanced technology enterprise which is professionally engaged in research, production, sales and service of adva... Beijing TIANYIHONGDA Science & Technology Development Co., LTD is located in Lize Business Circle area, a prosperous business area in the center of Beijing City, China. is a high and advanced technology enterprise which is professionally engaged in research, production, sales and service of adva...

+ Read More

Get in touch with us

  • Reach Us
  • Beijing Tianyihongda Science & Technology Development Co., LTD
  • Room1301, Building 11, yard 88 , Sanluju Road, Fengtai District, Beijing, China
  • https://www.powerlinefaultindicator.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement