Payment Terms | Western Union, L/C, T/T |
Supply Ability | 3000sets per week |
Delivery Time | 3000 sets within 1 week |
Packaging Details | 56*40*34cm,48 pcs /box ,standarad export box |
Indication | three high-intensity red LEDs, 360-degree visibility |
alarm | red flag and flashlight |
Handling charge | installing and removing while line is in charging condition |
Fault judge | identifying the Short-circuit fault , without testing the action value |
Brand Name | Tianyihongda |
Model Number | TYHD-8 |
Certification | type test report |
Place of Origin | Beijing,China |
View Detail Information
Explore similar products
35KV Communicable Fault Circuit Indicator For Underground Cable Data Transmissio
Overhead Distribution Lines Fault Circuit Indicator , Quickly Phase Loss
Earth Fault Circuit Indicator , Reliable Transmitting Short Circuit Detector
Remote Terminal Fault Circuit Indicator , GSM / GPRS High Voltage Cable Fault
Product Specification
Payment Terms | Western Union, L/C, T/T | Supply Ability | 3000sets per week |
Delivery Time | 3000 sets within 1 week | Packaging Details | 56*40*34cm,48 pcs /box ,standarad export box |
Indication | three high-intensity red LEDs, 360-degree visibility | alarm | red flag and flashlight |
Handling charge | installing and removing while line is in charging condition | Fault judge | identifying the Short-circuit fault , without testing the action value |
Brand Name | Tianyihongda | Model Number | TYHD-8 |
Certification | type test report | Place of Origin | Beijing,China |
High Light | short circuit indicator ,short circuit detector |
6KV-110KV epoxy resin insulated communicable fault passage indicator for overhead line
The fault indicator for overhead distribution lines is used indicating of phase-to-phase and phase-to-earth faults by determining short circuit, over-current and power features to detect faults and provide a local light indication. In addition, the indicator also has current measurement and wireless data communication capabilities, by sending the fault signal to FTU,in order to comply the function of the remote communication and the remote monitoring, to help operators to find the point of failure quickly and shorten the outage time and improve reliability.
The fault indicator installed on the overhead lines, which clipped on each phase so that to detect current and Voltage signal in this phase using itself clipped line structure. Through the low-power chip, it completes current calculation, short circuit, ground fault detection, and through built-in low-power RF modules achieves short distance wireless communication.
After the indicator is installed, the line current has been measured . When the current meet the characteristics of the fault, the indicator immediately sends the fault current and the fault information to the nearest terminal device by the RF, while triggering a flop and flash indication.
The lineman simple follows the flashing fault indicators all the way to the first non-flashing fault indicator, thereby identify the fault location.
The terminal device receives the fault information can further upload, so master station can get useful information and determine the fault zone according to the sub-station uploaded information.
Shocks and vibrations:
a)Power frequency magnetic field test
b)Grip test
Order Note:
The fault indicator is installed on the load side, and the phase number A1, B1, and C1 are installed on the main line, and the A2, B2 and C2 are installed on the branch line.
There is type test report for it,test items as following:
Type Test Items
| 1. appearance and structure 2.function 3. electrical device performance 4.low temperature performance 5.high temperature performance 6.alternating temperature humidity7.vibrationendurance 8.incline drop test 9. electrical device life 10. static electricity and elecro-discharge immunity test 11.radio frequency electromagnetic field radiated immunity test 12.surge impact immunity test 13. power frequency magnetic field immunity test. 14. Adjacent interference test 15.short-circuit withstand impact test 16. fire hazard test 17. power consumption test 18. protection grade test 19. gripping strength test of grip structure. |
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2014
Total Annual:
3000000-5000000
Employee Number:
150~180
Ecer Certification:
Site Member
Beijing TIANYIHONGDA Science & Technology Development Co., LTD is located in Lize Business Circle area, a prosperous business area in the center of Beijing City, China. is a high and advanced technology enterprise which is professionally engaged in research, production, sales and service of adva... Beijing TIANYIHONGDA Science & Technology Development Co., LTD is located in Lize Business Circle area, a prosperous business area in the center of Beijing City, China. is a high and advanced technology enterprise which is professionally engaged in research, production, sales and service of adva...
Get in touch with us
Leave a Message, we will call you back quickly!