Payment Terms | T/T, Paypal |
Supply Ability | 1000 units per month |
Delivery Time | 3-5 days |
Packaging Details | 1 unit: 64*44*55cm/ctn 18kg |
Product Name | High Flow Nasal Cannula(HFNC) Oxygen Therapy |
Application | Hospital (ICU/RICU) |
FiO2 | 21%-100% |
Flow | 1-10LPM; 2-18LPM; 6-60LPM and 10-120LPM(Custom) |
Pressure of gas source | Air/Oxygen @ 0.3-0.4 Mpa |
OEM/ODM | Support |
Blender Alarm | When gas supply pressure difference > 0.1 Mpa |
Blender Alarm Noise | >57 dB(A) |
Humidifier Supply Voltage/Frequency | 220V/ 110V 50/60Hz |
Brand Name | Union Medical |
Model Number | UN-HFNC01 |
Place of Origin | Wuhan, China |
View Detail Information
Explore similar products
0.7MPa High Flow System Oxygen Therapy 10-120L/Min Non Invasive
ICU RICU HHHF HFNC Oxygen Machine High Flow Nasal Cannula Oxygen Therapy
0.7MPa High Flow System Oxygen Therapy 10-120L/Min Non Invasive
Product Specification
Payment Terms | T/T, Paypal | Supply Ability | 1000 units per month |
Delivery Time | 3-5 days | Packaging Details | 1 unit: 64*44*55cm/ctn 18kg |
Product Name | High Flow Nasal Cannula(HFNC) Oxygen Therapy | Application | Hospital (ICU/RICU) |
FiO2 | 21%-100% | Flow | 1-10LPM; 2-18LPM; 6-60LPM and 10-120LPM(Custom) |
Pressure of gas source | Air/Oxygen @ 0.3-0.4 Mpa | OEM/ODM | Support |
Blender Alarm | When gas supply pressure difference > 0.1 Mpa | Blender Alarm Noise | >57 dB(A) |
Humidifier Supply Voltage/Frequency | 220V/ 110V 50/60Hz | Brand Name | Union Medical |
Model Number | UN-HFNC01 | Place of Origin | Wuhan, China |
High Light | HHHF HFNC Oxygen Machine ,ICU RICU HFNC Oxygen Machine ,High Flow Nasal Cannula Oxygen Therapy |
Adult Infant High Flow Nasal Cannula Oxygen Therapy Heated Respiratory Humidifier HHHF HFNC Machine
Description:
Specifications:
Adjustment Method of Oxygen Concentration | Merchanical |
---|---|
FiO2 | 21%-100% |
Flow | 0.1-1 LPM, 1-10LPM, 2-18LPM, 1-15LPM(Infant) 6-60LPM, 7-70LPM, 10-120LPM(Adult) |
Pressure of gas source | Air/Oxygen @ 0.3-0.4 Mpa |
Blender Alarm | When gas supply pressure difference > 0.1 Mpa |
Blender Alarm Noise | >57 dB(A) |
Accuracy of FiO2 | 3% |
Humidifier Supply Voltage/Frequency | 220V/ 110V 50/60Hz |
Humidifier Temperature monitoring | 0-75℃ |
Humidifier Heater Plate Over-temperature Cut Off | 95±5℃ |
Heater Wire(Max.) | 22V-,2.73A, 60W, 50/60Hz |
Humidifier Temperature control settings | Heated wire mode(mode indicator lighted) Temperature grade(with indicator status) Continuous flow range Delivered patient temperature P1 (●○○) 5L/min-60L/min 25-29℃ P2 (●●○) 5L/min-60L/min 29-35℃ P3 (●●●) 5L/min-60L/min 35-39℃ Non-heated wire mode(It is not recommended in adult HFNC. Operate manual of humidifier show details) |
Configuration of HFNC Machine:
Company Details
Business Type:
Manufacturer,Importer,Trading Company,Seller
Year Established:
2013
Total Annual:
1000000-50000000
Employee Number:
1~51
Ecer Certification:
Active Member
We,Wuhan Union Medical Technology CO.,Ltd,is a R&D company in patient monitoring solutions,which started in 2009 with leading engineers in China,and established in 2013.Union Medical is committed to the techniques and products of monitoring, diagnosing, supporting and treating the biological i... We,Wuhan Union Medical Technology CO.,Ltd,is a R&D company in patient monitoring solutions,which started in 2009 with leading engineers in China,and established in 2013.Union Medical is committed to the techniques and products of monitoring, diagnosing, supporting and treating the biological i...
Get in touch with us
Leave a Message, we will call you back quickly!