Payment Terms | T/T in advance, Western Union |
Supply Ability | 50pcs/week |
Delivery Time | Within 3 days after receiving payment |
Packaging Details | Standard package |
accuracy | 0.01mm |
memory | 400 |
key words | ultrasonic thickness gauge price |
Display | 4 digits LCD |
Measuring range | 0.70~300.0mm in steel with PT-5 probe |
Resolution | 0.01mm@0.70~99.99mm, 0.1mm@100.0~300.0mm |
Accuracy | 0.70~9.99mm ±0.05mm / 10.00~99.99mm ±(0.5%+0.01)mm 100.0~300.0 ±(1%+0.1)mm |
Unit | mm/inch |
Velocity | 1000~9999m/s |
Memory | 400 data |
Brand Name | SADT |
Model Number | SA40+ |
Certification | CE ISO9001 SGS |
Place of Origin | Beijing |
View Detail Information
Explore similar products
Portable Ultrasonic Thickness Gauge price SA40+ which can test thickness covered
SA10 Miniaturized Ultrasonic Thickness Gauge from 1.2225mm with 5P probe at
Portable Ultrasonic Thickness Gauge 0.7mm - 300mm Pulse Echo With Dual Probe
Portable wall thickness gauge SA40+ with normal and multiple echo(MEC) mode in
Product Specification
Payment Terms | T/T in advance, Western Union | Supply Ability | 50pcs/week |
Delivery Time | Within 3 days after receiving payment | Packaging Details | Standard package |
accuracy | 0.01mm | memory | 400 |
key words | ultrasonic thickness gauge price | Display | 4 digits LCD |
Measuring range | 0.70~300.0mm in steel with PT-5 probe | Resolution | 0.01mm@0.70~99.99mm, 0.1mm@100.0~300.0mm |
Accuracy | 0.70~9.99mm ±0.05mm / 10.00~99.99mm ±(0.5%+0.01)mm 100.0~300.0 ±(1%+0.1)mm | Unit | mm/inch |
Velocity | 1000~9999m/s | Memory | 400 data |
Brand Name | SADT | Model Number | SA40+ |
Certification | CE ISO9001 SGS | Place of Origin | Beijing |
High Light | MEC Ultrasonic Coating Thickness Gauge ,Portable Ultrasonic Coating Thickness Gauge ,Backlight Ultrasonic Coating Thickness Gauge |
Portable Ultrasonic Thickness Gauge price SA40+ which can test thickness covered with coating
Introduction
SA40+ is the miniaturized ultrasonic thickness gauges that can measure wall thickness and velocity.
Using new technique of multiple echo(echo-to-echo), SA40+ can measure wall thickness under paint. For a normal ultrasonic thickness gauge, you must remove paint on work piece, but with new SA40+, you can take measurement directly over the paint of work piece and you can get real thickness value of work piece. SA40+ has two measuring modes: normal mode and multiple echo(MEC) mode. By normal mode, SA40+ is a normal ultrasonic thickness gauge; by MEC mode, SA40+ can measure over coatings.
Specifications
1) Technique: pulse echo with dual probe
2) Display: 4 digits LCD with backlight
3) Measuring range: 0.7 to 300.0mm
4) Resolution : 0.01mm 0.8-99.99mm, 0.1mm 100.0-300.0mm
5) Velocity range: 500-9999m/sec.
6) Display circle: 1 sec.
7) Coupling indication
8) Memory: 400 data can be stored and re-readable
9) Units: mm or inch
10) Low battery indicator on LCD
11) Auto shut-off: after 5 min. of non-use
12) Power: 2 ea. 1.5V AA alkaline cells
13) Operating temperature: 0-40°C
14) Operating humidity: 20-90%RH
15) Size: 124x67x30mm
16) Weight: 240g
Specificaiton:
Model | SA40+ |
---|---|
Display | 4 digits LCD |
Backlight | Yes |
Measuring range | 0.7.00~300.0mm in steel with standard probe (Normal mode) 3.00~20.00mm in steel Thickness for coating: <1.2mm (Coating mode) |
Resolution | 1.00~9.99mm ±0.05 10.00~99.99mm ±(0.5% H+0.01) 100.0~225.0 ±(1% H+0.1) |
Unit | mm/inch |
Velocity | 1000~9999m/s |
Coupling indicator | Yes |
Calibration | Auto |
Memory | 40 data |
Low battery indicator | Yes |
Working environment | 0~40oC, 20~90%RH |
Power off | Auto |
Power supply | AA battery x 2 |
Net weight (g) | 245 |
Dimension (mm) | 124x67x30 |
Standard probe | PT-5 |
Optional probes | XT-5 / GT-5 / CT2.5 |
Materials thickness with maximum 400℃ surface temperature could be measured using high temperature probe GT-5. Precautions: when measuring thermal materials:
Apply high temperature couplant, measure immediately after the couplant melts, the probe contact shall be less than 10 seconds and the interval between two measurements shall be no less than 1 minute.
Prevent the probe from being vibrated; otherwise the probe will be damaged.
When the temperature of thermal material increases 100℃, the velocity decreases about 1%. Correction needs to be done to the measuring values.
E.g.: we can define δ0 as the actual thickness of the material, δt as the display value in the instrument
Then:
When 125℃, δ 0 =δ t×0.99
When 225℃, δ 0 =δ t×0.98
When 325℃, δ 0 =δ t×0.97
Also, when we know accurately the material temperature to be measured, we can also correct the velocity of the instrument.
For example: under normal temperature (25℃), velocity of the material =5900 m/s,
When 125℃, velocity ≈5840m/s
When 225℃, velocity ≈5780m/s
When 325℃, velocity ≈5720m/s
Then, the displayed value is the actual value of the material.
Standard package
SA40+ main unit 1
Standard 5MHz probe PT-5 with
probe holder 1
Built-in calibration block 1
Coupling paste for normal temperature 1
Test certificate 1
Operation manual 1
Carrying case 1
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Importer,Exporter,Seller
Year Established:
1993
Total Annual:
3 million-4 million
Employee Number:
>30
Ecer Certification:
Active Member
Sino Age Development Technology, Ltd. (SADT), established in 1993, is a leading manufacturer for measuring and testing instrument, specialized in NDT and quality control fields. We have our own HARTIP series portable hardness testers since 1995. We are professional producer with ISO 9001 quality sys... Sino Age Development Technology, Ltd. (SADT), established in 1993, is a leading manufacturer for measuring and testing instrument, specialized in NDT and quality control fields. We have our own HARTIP series portable hardness testers since 1995. We are professional producer with ISO 9001 quality sys...
Get in touch with us
Leave a Message, we will call you back quickly!