China factories

China factory - Nanjing Kelisaike Safety Equipment Co., Ltd.

Nanjing Kelisaike Safety Equipment Co., Ltd.

  • China,Nanjing ,Jiangsu
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China DOAS Industrial UV Gas Analyzer No O2 Safety Monitoring With Spectrum Analysis
China DOAS Industrial UV Gas Analyzer No O2 Safety Monitoring With Spectrum Analysis

  1. China DOAS Industrial UV Gas Analyzer No O2 Safety Monitoring With Spectrum Analysis
  2. China DOAS Industrial UV Gas Analyzer No O2 Safety Monitoring With Spectrum Analysis
  3. China DOAS Industrial UV Gas Analyzer No O2 Safety Monitoring With Spectrum Analysis

DOAS Industrial UV Gas Analyzer No O2 Safety Monitoring With Spectrum Analysis

  1. MOQ: 1PC
  2. Price:
  3. Get Latest Price
Stock 1PC
Payment Terms T/T, Western Union, Paypal
Shipping Method LCL, AIR, FCL, Express
Model KF100
Response Time Less than 10s
Power 220V AC/50Hz 100W
Protection Grade IP42
Sample Gas Input and Output Interface ø 6 Tube Fittings
Specification 19"x3Ux320mm
Transport Package Carton

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Stock 1PC Payment Terms T/T, Western Union, Paypal
Shipping Method LCL, AIR, FCL, Express Model KF100
Response Time Less than 10s Power 220V AC/50Hz 100W
Protection Grade IP42 Sample Gas Input and Output Interface ø 6 Tube Fittings
Specification 19"x3Ux320mm Transport Package Carton
High Light Industrial UV Gas AnalyzerSafety Monitoring UV Gas AnalyzerSpectrum Flue Gas Analysis

Industrial Safety So2 No O2 Monitoring Doas Technology Spectrum Analysis UV Flue Gas Analyzer Control

 

 

Product Description

 

    The analyzer based on UV absorption spectroscopy and chemometric algorithms to measure SO2, NOx, O2, NH3, Cl2, O3, H2S and other gases concentration, with high accuracy, high reliability, fast response time, wide application and other characteristics, the indicators have reached or exceeded similar products, it can be widely used in environmental online monitoring, industrial control, security monitoring and other occasions.

 

Key Features

 

 

Full spectrum measurement and DOAS (Differential Optical Absorption Spectroscopy) algorithm, excelling in accuracy, repeatability and anti-interference with moisture, dust.

Modular design and no moving parts, higher reliability and easier maintenance. Pulse Xenon Lamp used as light source with over 10-year lifetime.

The adoption of diode array sensor enables instant spectrum acquisition and rapid response

 

 

 

Features and Benefits

 

 

1. Analyzer uses the following optical technology platform to get the UV absorption spectrum, the technology platform consists of light source, gas chamber, fiber optics and spectroscopy (including the diaphragm, holographic gratings, linear array detector) and other optical components.

 

2. UV-visible light emitted by the optical window into the gas chamber, is absorbed by the sample gas flowing through the measured gas chamber, carrying the tested sample gas absorbs light through the lens after gathering information coupled into optical fiber through the optical fiber transmission into the spectrometer splitting, sampling, to obtain the absorption spectrum of the gas.

 

3. Use DOAS technology spectrum analysis, can analyze the concentration of the gas in the relevant component.

 

 

 

Measuring principle

 

 

1) The light source emits ultraviolet beam which transfers to gas cell through optical fiber.

2) After absorption by measuring gas, the light beam transfers through optical fiber to spectrometer.

3) Being dispersed through the grating, dispersed spectral optical signals are converted into electric signal by the CCD array sensor. By DOAS the continuous absorption spectrum of obtained measuring gas is thereafter used to get a plurality of kinds of gases(such as SO2 NO) at the same time.

 

 

 

 

Technical Specification

 

 

 

SO2, NOx Analyzer

 

Technical Principle

 

UV-DOAS

 

Installation type

 

Hot-wet Extractive

 

Measurement Range

 

0~200ppm, 0~1000ppm, 0~3000ppm

 

Zero Drift

 

±2%F.S.

 

Span Drift

 

±2%F.S.

 

Accuracy

 

±1%

 

Response Time(T90)

 

60s

 

Linearity

 

±1%F.S.

 

O2 Analyzer

 

Technical Principle

 

Zirconia/Electrochemical

 

Measurement Range

 

0~25%

 

Response Time(T90)

 

60s

 

Linearity

 

±2%F.S.

 

CO, CO2 Analyzer

 

Technical Principle

 

NDIR

 

Installation type

 

Extractive

 

CO Measurement Range

 

0~1000 ppm

 

CO2 Measurement Range

 

0~20%

 

Zero Drift

 

±2%F.S.

 

Span Drift

 

±2%F.S.

 

Accuracy

 

±1%

 

Response Time(T90)

 

60s

 

Linearity

 

±2%F.S.

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller

  • Year Established:

    2004

  • Total Annual:

    1300000-2000000

  • Employee Number:

    100~300

  • Ecer Certification:

    Verified Supplier

Nanjing KELISAIKE Safety Equipment Company is one of the largest safety equipment manufacturers, possessing complete product ranges and specifications in the safety equipment industry of mainland China. Founded in 2004, Nanjing KELISAIKE has set three subsidiaries in Beijing, Xi'an, and Xinjiang... Nanjing KELISAIKE Safety Equipment Company is one of the largest safety equipment manufacturers, possessing complete product ranges and specifications in the safety equipment industry of mainland China. Founded in 2004, Nanjing KELISAIKE has set three subsidiaries in Beijing, Xi'an, and Xinjiang...

+ Read More

Get in touch with us

  • Reach Us
  • Nanjing Kelisaike Safety Equipment Co., Ltd.
  • Bldg 12, 2 Qingshuiting West Road, Nanjing, Jiangsu, China, 211102
  • https://www.portable-gasdetector.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement