Packaging Details | AQMS in Wooden case |
Stock | 1PC |
Warranty | 1 year |
Type | Gas analyzer, AQMS-H6 |
Customized support | OEM, ODM |
Name | AQMS Air Quality Monitoring System |
PM2.5 | (0~10000) μg/m³ |
PM10 | (0~10000) μg/m³ |
Indication error | ±15% |
Resolution | 0.1μg/m³ |
LOD | 2μg/m³ |
Sampling flow | 2.83 L/min,precision ±2.5%, with the cyclone cutter |
Grain size | PM2.5, PM10 or TSP |
Temperature control | (10~60)℃ |
Place of Origin | Jiangsu, China |
Brand Name | KELISAIKE |
Model Number | AQMS-H6 |
Certification | CE |
View Detail Information
Explore similar products
Real Time 220V AC Air Quality Monitoring System Outdoor Use For Accurate
AQMS H6 Micro Ambient Air Quality Monitoring Device 220V AC Heat Resistant
High Sensitivity 2000g Fixed Air Quality Monitoring System Of Combustible Gases
220V 50HZ Customized Outdoor Air Quality Sensor AQMS For Air Monitoring
Product Specification
Packaging Details | AQMS in Wooden case | Stock | 1PC |
Warranty | 1 year | Type | Gas analyzer, AQMS-H6 |
Customized support | OEM, ODM | Name | AQMS Air Quality Monitoring System |
PM2.5 | (0~10000) μg/m³ | PM10 | (0~10000) μg/m³ |
Indication error | ±15% | Resolution | 0.1μg/m³ |
LOD | 2μg/m³ | Sampling flow | 2.83 L/min,precision ±2.5%, with the cyclone cutter |
Grain size | PM2.5, PM10 or TSP | Temperature control | (10~60)℃ |
Place of Origin | Jiangsu, China | Brand Name | KELISAIKE |
Model Number | AQMS-H6 | Certification | CE |
High Light | PM2.5 Industrial Air Quality Monitor ,PM10 Industrial Air Quality Monitor ,PM2.5 Ambient Air Quality Monitoring System |
High precision AQI air quality monitoring station dust particulate matters PM2.5 PM10 monitoring system
Introduction:
Micro Ambient Air Quality Monitoring System is an economical product for providing real-time and accurate detection of outdoor air pollutants, with the performance close to the level of automatic monitoring system. Compared with lower price alternatives on the market, H6 provides accurate detection data comparable to standard stations. After calibration on site according to certified reference standards, it can reach the optimal traceability. Therefore, as an air quality monitoring system, it has high cost efficiency.
Main Features:
• No need to change the sample cutter, able to measure the mass concentration of PM10 and PM2.5
• On-site calibration according to traceable reference standards;
• Optional zero gas calibration modules;
• Imported high precision four- electrode sensors;
• Modular design for configuration of any combination, easy to set different monitoring parameters on demand, suitable for large-scale grid distribution points
• Embedded processor of industrial grade for the circuit, suitable for harsh outdoor environments, with working environment temperature range of -50 to 100℃;
• Dynamic heating control for air particulate sampling to remove the influence of water and fog on the measured data;
• An electronic flowmeter used to the measure the sampling flow speed of particulates and gaseous pollutants.
• Stable and reliable data transmission with the industrial grade data transmission module;
• Dual-channel communication mode to realize communication in extreme cases and ensure data continuity;
• Modular design, and high reliability CAN bus communication between modules; automotive electronic communication protocol to ensure the stability of the system;
• Remote data transmission and system state information readable remotely, as well as remote control, remote modification of instrument parameters, and fault diagnosis;
• Remote upgrade of terminal applications via the FTP server to realize tele-maintenance and ensure that users can use the latest applications and update system functions timely;
• Optional five meteorological parameters tester;
• Optional IP cameras with various parameters to ensure night and visual range shooting requirements, with automatic snapshot and real-time monitoring functions.
• On-site real-time data display: end instruments renew data every 5 seconds.
• The optional data service platform can display average minute, hourly and daily values. Report analysis function can generate daily, monthly and yearly reports, as well as trend reports. Same screen multi-points display, supporting mobile terminal data query and data push to the display terminal;
•Various installation methods, to be selected according to the site situation: spport, pole, etc. Each type of mounting is tight and secure and can resist the instantaneous 12 level wind force.
Technical Parameters:
Gases | Measurement range(ppb) | Resolution (ppb) | LOD(ppb) | 24 h drift zero / ppb |
O3 | 0-1000 | 1 | ≤10 | 5%F.S |
NO2 | 0-1000 | 1 | ≤10 | 5%F.S |
CO | 0-20000 | 1 | ≤150 | 5%F.S |
SO2 | 0-1000 | 1 | ≤10 | 5%F.S |
H2S(optional) | 0-20000 | 1 | ≤150 | 5%F.S |
VOC(optional) | 0-40000 | 1 | ≤150 | 5%F.S |
Particulates:
Measurement range | PM2.5:(0~10000) μg/m³ , PM10:(0~10000) μg/m³ |
Indication error | ±15% |
Sampling flow | 2.83 L/min,precision ±2.5%, with the cyclone cutter |
Grain size | PM2.5, PM10 or TSP |
LOD | 2μg/m³ |
Resolution | 0.1μg/m³ |
Temperature control | (10~60)℃,temperature control accuracy ±1℃ |
Data storage | Up to one year |
USB interface | Support USB data export |
Remote data query | DTU module for remote query of instrument working status and real-time measurement data |
Fault Alarm | Real-time display of fault alarm |
Air intake heating | Dynamic heating of intake tube and Automatic temperature and humidity compensation |
Optional
Meteorological parameters:
Temperature | Measuring range:-50 ~100℃ | RH | Measuring range: 0~100%RH |
Resolution: 0.1℃ | Resolution: 0.1%RH | ||
Accuracy:±0.5℃ | Accuracy:±3%RH | ||
Wind speed | Measuring range: 0~70m/s | Resolution: 0.1m/s | |
Start wind speed≥0.5m/s | Accuracy:±0.3m/s | ||
Wind direction | Measuring range: 0~360° | Resolution:±0.1° | |
Start wind speed≥0.5m/s | Accuracy:±3° | ||
Atmospheric pressure | Measuring range: 10~1100hpa | ||
Resolution: 0.1hpa | |||
Accuracy: ±0.5hpa |
Noise Parameters
Noise | IEC61672:2002 level 2 GB/T3785-2012 level 2 Level 1 noise level meter available | Frequency range | 16~20KHz |
Measurement range | 30~140 dB | Frequency weighting | A, C, Z |
Principle of noise sensor: High precision capacitive free-field microphone |
Main Qualifications
CCEP China Certification of Environmental Products
CMA Test Report
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller
Year Established:
2004
Total Annual:
1300000-2000000
Employee Number:
100~300
Ecer Certification:
Verified Supplier
Nanjing KELISAIKE Safety Equipment Company is one of the largest safety equipment manufacturers, possessing complete product ranges and specifications in the safety equipment industry of mainland China. Founded in 2004, Nanjing KELISAIKE has set three subsidiaries in Beijing, Xi'an, and Xinjiang... Nanjing KELISAIKE Safety Equipment Company is one of the largest safety equipment manufacturers, possessing complete product ranges and specifications in the safety equipment industry of mainland China. Founded in 2004, Nanjing KELISAIKE has set three subsidiaries in Beijing, Xi'an, and Xinjiang...