China factories

China factory - BOGEN PUMPS

BOGEN PUMPS

  • China,Foshan ,Guangdong
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Pneumatic Double AODD Pump Submersible Diaphragm Pump 0.83Mpa For Mining
China Pneumatic Double AODD Pump Submersible Diaphragm Pump 0.83Mpa For Mining

  1. China Pneumatic Double AODD Pump Submersible Diaphragm Pump 0.83Mpa For Mining
  2. China Pneumatic Double AODD Pump Submersible Diaphragm Pump 0.83Mpa For Mining
  3. China Pneumatic Double AODD Pump Submersible Diaphragm Pump 0.83Mpa For Mining

Pneumatic Double AODD Pump Submersible Diaphragm Pump 0.83Mpa For Mining

  1. MOQ: 10 Unit(s)
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms FOB T/T
Supply Ability 1000 Unit(s) Per Month
Guarantee: one year
product name pneumatic double diaphragm pump
Weight 12.3kg
Material Cast steel,Alu,SS,PP
Maximum air inlet pressure 0.83Mpa
Place of Origin China
Brand Name BSK
Model Number BSKA25AL-P99-A

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms FOB T/T Supply Ability 1000 Unit(s) Per Month
Guarantee: one year product name pneumatic double diaphragm pump
Weight 12.3kg Material Cast steel,Alu,SS,PP
Maximum air inlet pressure 0.83Mpa Place of Origin China
Brand Name BSK Model Number BSKA25AL-P99-A
High Light air operated double diaphragm aodd pumpspositive displacement diaphragm pump

Air Driven Membrane Pumps Submersible Diaphragm Pump for Mining

 

 

diaphragm pump offers high volume delivery even at low air pressure and a b road range of material compatibility options available.Refer to the model and option chart.pump is provided with the modularized air motor and fluid section.

The air operated diaphragm pump alternately generates the intake fluid pressure and positive fluid pressure in the fluid chamber by using the pressure difference in the air chamber. The ball valve can ensure the forward flow of fluid.

Pump cycling will begin as air pressure is applied and it will continue to pump and keep up with the demand. It will build and maintain line pres -sure and will stop cycling once maximum line pressure is reached (dis -pensing device closed) and will resume pumping as needed.

 

Air diaphragm pump(also know as a Membrane pump, air operated double diaphragm pump(AOOD) or pneumatic diaphragm pump)that uses a combination of the reciprocating action of a rubber,thermoplastic or diaphragm and suitable valves either side of the diaphragm (check valve,butterfly valves,flap valves,or any other form of shut-off valves) to pump a fluid.

 

Item Description Unit Reference Figure
1 Maximum air inlet pressure Mpa 0.83
2 Maximum flow rate 1/Min 192
3 Maximum lift M 70
4 Maximum outlet pressure Mpa 0.83
5 Maximum particle size mm 3
6 Weight kg 12.3
7 Noise level db <70

 

 

Specifications

 

Air Diaphragm Pump
1. Non leakage
2. Good self priming performance
3. Convey all kinds of medium
4. Material:Cast steel,Alu,SS,PP

 

 

A 2 5 X X - X X X - X   (model selection)

 

Form of pipe mouth:A-BSP B-NPT(F) C-Flange  

Diaphragm material:9 – Santoprene H – Hytrel   T - PTFE/Santoprene  

Ball material:9 -Santoprene H – Hytre T – PTFE A - Acetal  

Ball seat material:P/K –Polypropylene/Kynoar SS –Stainless Steel  

Pump material: SS –Stainless Steel AL –Aluminum Alloy   CI- Carbon Steel P/K –Polypropylene/Kynoar

 

 

Main Performance Parameters  

 

No. Parameter Names Units Reference Values  

1 Max. Working Air Pressure Mpa 0.83  

2 Max. Flow l/min 135  

3 Max. Head m 70  

4 Max. Fluid Output Pressure Mpa 0.83  

5   Max. Particle Through   Diameter   mm 3  

6 Weight kg   9.5/12.5 ( PP/KV ) /9.5 (AL)/   14.5(SS/CI)  

7 Noise Level db <85  

 

Maximum Applied Temperature Limits (diaphragm / ball / seal material)  

 

 

Acetal ···············································40°-         150°F        (4.4- 65.5°C)  

Santoprene·········································-40°- 225°F (-40°- 107.2°C)   ·················································40°- 220°F (4.4°- 104°C)   Nitrile··················································10°- 180°F (-12°- 82°C)   Viton···················································-40°- 350°F (-40°-176.6°C)   Hytrel···················································-20°-150°F (-12°- 93°C)   Kynar···················································10°-200°F (-28.9°- 65.5°C)   Polypropylene··········································32°- 175°F (0-79.4°C)

 

 

1”  Flow diagram

 

 

 

 

 

 

 

Requirements for Air and Lubrication

 

 

EXCESSIVE AIR PRESSURE. Can cause pump damage, personal injury or property damage.

  • A filter capable of filtering out particles larger than 50 microns should be used on the air supply. There is no lubrication required other than the “O” ring lubricant which is applied during assembly or repair.
  • If lubricated air is present, make sure that it is compatible with the “O” rings and seals in the air motor section of the pump.

 

 
 

OPERATING INSTRUCTIONS

 

  • Always flush the pump with a solvent compatible with the material being pumped if the material being pumped is subject to “setting up” when not in use for a period of time.
  • Disconnect the air supply from the pump if it is to be inactive for a few hours.
  • The outlet material volume is governed not only by the air supply but also by the material supply available at the inlet. The material supply tubing should not be too small or restrictive. Be sure not to use hose which might collapse.
  • When the diaphragm pump is used in a forced -feed (flooded inlet) situation, it is recommended that a “Check Valve” be installed at the air inlet.
  • Secure the diaphragm pump legs to a suitable surface to insure against damage by vibration.

 

 

Maintenance

 

  • Please refer to the component schematic in the assembly drawings to look up the serial numbers and names of parts and grasp the information of parts and maintenance service pack.
  • Some BSK parts are marked as "wearing parts", which can conduce to quick service and downtime reduction.
  • Service kits are divided to service two separate diaphragm pump functions: 1. AIR SECTION, 2. FLUID SECTION. The FLUID SEC -TION is divided further to match typical part MATERIAL OPTIONS.
  • Provide a clean work surface to protect sensitive internal moving parts from contamination from dirt and foreign matter during service disassembly and reassembly.
  • Keep good records of service activity and include pump in preven -tive maintenance program.
  • Before disassembling, empty captured material in the outlet man -ifold by turning the pump upside down to drain material from the pump.

 

 

FLUID SECTION DISASSEMBLY

 

  • Remove the upper and lower manifold (1) and (11).
  • Remove the ball (2), “O” ring (3) (47) and ball seat (4).
  • Remove the fluid cap (5).

    NOTE: Only diaphragm models use a primary diaphragm(6A) and a backup diaphragm(6). Refer to the aux iliary   view in the Fluid Section illustration.

  • Remove the screw (10), washer (9), diaphragm (6A, 6) and diaphragm washer (7, 8).
    NOTE: Do not scratch or mar the surface of (23) diaphragm rod.

 

 

FLUID SECTION REASSEMBLY

 

  • Reassemble in reverse order.
  • Clean and inspect all parts. Replace worn or damaged parts with new parts as required.
  • Lubricate (23) diaphragm rod and 25) “Y” ring with grease.
  • Fix the diaphragm rod (23) with the auxiliary installation tool.
  • Prior to the final fastening of bolts and nuts, please determine whether the diaphragm (6A,6) is aligned with the fluid cap (5) properly to avoid the twisting of the diaphragm.
  • For the models using diaphragm: three rubber diaphragms (6) on the side, which are marked with AIRS SIDE "air chamber" are mounted in face of the pump body.
  • Start the pump, check the fastening and sealing after it runs for a period of time.

 

Installation dimensions:

 

 

 

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Importer,Exporter

  • Year Established:

    2001

  • Total Annual:

    100000-300000

  • Employee Number:

    >200

  • Ecer Certification:

    Verified Supplier

BOGEN As a company absorbed in fluid transportation who invented the world's first dualceramic air valve system! Its highly valued by customers for its unique patentedtechnology and nanny service, high quality, wide applicable area, and excellentstability.In 2011 set up its factor... BOGEN As a company absorbed in fluid transportation who invented the world's first dualceramic air valve system! Its highly valued by customers for its unique patentedtechnology and nanny service, high quality, wide applicable area, and excellentstability.In 2011 set up its factor...

+ Read More

Get in touch with us

  • Reach Us
  • BOGEN PUMPS
  • E 18Floor Fazhan Build No.13 Easy Huayuan Road Chancheng Area Foshan City.
  • https://www.airdrivendiaphragmpump.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement