Payment Terms | T/T, PayPal, Western Union |
Supply Ability | 100000pcs per month |
Delivery Time | Negotiation |
Packaging Details | inner boxes,cartons,pallets |
Hole Size | 8.3mm |
Height | 30.5mm |
Width | 34.0mm |
Voltage | AC24-240V (50Hz/60Hz), DC12-48V |
Power | 5W |
Connector | 2 PIN Connector |
Insulation Class | F |
Protection Class | IP65, IP67, IP68 |
Application | Water Filtration System, Water Purificat |
Brand Name | BRANDO |
Model Number | BB08330538 |
Certification | None |
Place of Origin | Ningbo, China |
View Detail Information
Explore similar products
24VDC Solenoid Coil For DAF Truck Solenoid Valve 1318860 1334037
ASCO Type Pulse Jet Valve Solenoid Coil 400325-142 24VDC 11W
Lovato Type LPG Autogas RGE/RGV Reducer Valve Solenoid Coil DC12V 13mm Hole
DC24V / AC220V K23D-3 Pilot Operated Pneumatic Solenoid Coil 17.5mm x 50.5mm x
Product Specification
Payment Terms | T/T, PayPal, Western Union | Supply Ability | 100000pcs per month |
Delivery Time | Negotiation | Packaging Details | inner boxes,cartons,pallets |
Hole Size | 8.3mm | Height | 30.5mm |
Width | 34.0mm | Voltage | AC24-240V (50Hz/60Hz), DC12-48V |
Power | 5W | Connector | 2 PIN Connector |
Insulation Class | F | Protection Class | IP65, IP67, IP68 |
Application | Water Filtration System, Water Purificat | Brand Name | BRANDO |
Model Number | BB08330538 | Certification | None |
Place of Origin | Ningbo, China | ||
High Light | Solenoid Coil ,Solenoid Valve Coil ,Electromagnetic Coil |
RO Water Filtration System Part Small Diaphragm Plastic Solenoid Valve Coil
Applicable Industries:Solenoid Valve
Type:Fittings
Place of Origin:Zhejiang, China
Brand Name:Brando
Hole Size:8.3mm
Height:30.5mm
Width:34.0mm
Voltage:AC24-240V (50Hz/60Hz), DC12-48V
Power:5W
Insulation class:F
Protection class:IP65, IP67, IP68
Applications:Water Filtration System, Water Purification System, Domestic RO System
Dimension of Plastic Solenoid Valve Coil :
Technical Data:
Model | BB08330538 |
Hole size | 8.3mm |
Height | 30.5mm |
Width | 34.0mm |
Voltages | AC24-240V (50Hz/60Hz), DC12-48V |
Power | 5W |
Insulation class | F |
Application examples | Water Filtration System, Water Purification System, Domestic RO System, Small RO Water Treatment System |
Details:
![]() | ![]() | ![]() |
Hole size 8.3mm | Height 30.5mm | Width 34.0mm |
Solenoid Coil Production Line:
Attention:
1. This air suspension compressor pump solenoid coil is made of high quality components.
2. Replaces the original air compressor solenoid coil of your car and equal the original quality.
3. Please double confirm the compatibility as well as the OEM number before purchasing.
4. Instruction is not included. Professional installation is recommended.
Why does a coil get burnt when removed from valve?
This is because with AC 50/60Hz coils you are reducing the impedance or resistance of the coil, as the shading ring within the armature or stem generates resistance within the coil. By removing the coil whilst powered the resistance is reduced thus the power consumption can easily increase above the coil winding class limits causing over heating.
Steps and methods for properly installing a solenoid valve coil:
1. Check if the solenoid valve and the selected parameters are the same, such as differential pressure, etc. If the error occurs, the solenoid valve coil will be burned out. Voltage fluctuations should be within the normal range and meet the rated voltage.
2. Before connecting the pipeline, flush the pipeline and remove the residual dirt in the pipeline. If there are residual stains, it will affect the normal use of the solenoid valve. To prevent this, a filter should be installed in the pipeline.
3. Install the solenoid valve coil of the solenoid valve vertically on the horizontal and ground pipes. If there is a special situation, it cannot be installed vertically. The appropriate solenoid valve should be ordered in advance, otherwise the solenoid valve will not work properly.
4. When installing, add a safety process and install a manual cutting valve to facilitate maintenance in case of failure.
5. Pay attention to the direction when installing, can not be reversed, installed in the direction indicated on the package, and can be reversed in some special cases such as vacuum.
6. If the water may be damaged by the medium, you must take appropriate protective measures or choose a solenoid valve with a waterproof hammer function.
7. The solenoid valve cannot be energized all the time, otherwise it will reduce its life. Note that normally open, normally closed solenoid valves cannot be used with care.
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter,Seller
Year Established:
2008
Total Annual:
8million-9million
Employee Number:
50~100
Ecer Certification:
Verified Supplier
* Foucus on your demand, Offer you best solutions as the first mission of Ningbo Brando Hardware Co., Ltd, we work on designing and manufacturing solenoid coils, solenoid armatures and solenoid valves for more than 15 years. * We have served customers fr... * Foucus on your demand, Offer you best solutions as the first mission of Ningbo Brando Hardware Co., Ltd, we work on designing and manufacturing solenoid coils, solenoid armatures and solenoid valves for more than 15 years. * We have served customers fr...
Get in touch with us
Leave a Message, we will call you back quickly!