Payment Terms | T/T in advance,Western Union,Paypal,Credit card |
Supply Ability | 2000 pcs |
Delivery Time | within 1-30 working days after payment |
Packaging Details | Boxes, Cantons, Plastic bags |
Body | Aluminium |
Core tube | Stainless steel |
Seals & disc | NBR (nitrile) |
Differential pressure | 0,35 - 8,5 bar [1 bar = 100kPa] |
Ambient temperature range | -20 to +85°C |
Brand Name | or OEM |
Model Number | SCG353A047 |
Certification | ce |
Place of Origin | China, USA |
View Detail Information
Explore similar products
FLY/AIRWOLF Solenoid Valve Pneumatic Pulse Jet Valves
CA20T 3/4" RCA20T PA-6 Standard T Series 24v FLY/AIRWOLF Pneumatic Pulse Jet
CA-25MM,RCA-25MM MM Series Aluminum Diecast FLY/AIRWOLF RCA Pilot Pulse Jet
MM Series fluororubber FLY/AIRWOLF RCA Pilot Pulse Jet Valves CA-50MM,RCA-50MM
Product Specification
Payment Terms | T/T in advance,Western Union,Paypal,Credit card | Supply Ability | 2000 pcs |
Delivery Time | within 1-30 working days after payment | Packaging Details | Boxes, Cantons, Plastic bags |
Body | Aluminium | Core tube | Stainless steel |
Seals & disc | NBR (nitrile) | Differential pressure | 0,35 - 8,5 bar [1 bar = 100kPa] |
Ambient temperature range | -20 to +85°C | Brand Name | or OEM |
Model Number | SCG353A047 | Certification | ce |
Place of Origin | China, USA | ||
High Light | 1.5 Inch Pulse Jet Valves , SCG353A047 ,24VDC Pulse Jet Valves |
FEATURES
• The pulse diaphragm valves are especially designed for dust collector service applications, combining high flow, long life and extremely fast opening and closing to produce reliable and economical operation
• Integral pilot operated valves satisfy all relevant EC directives
Ordering Code | Port Size | Orifice | Flow Value | Coil type | |
G Threaded | mm | m3/h | l/min | ||
SCG353A047 | 1 1/2" | 52 | 46 | 768 | 400425 |
SCG353A050 | 2" | 66 | 77 | 1290 | 400425 |
SCG353A051 | 2 1/2" | 66 | 92 | 1540 | 400425 |
SCG353.060 | 3" | 75 | 170 | 2833 | 400425 |
Construction | |
Body | Aluminum |
Core tube | Stainless steel |
Core and Plugnut | Stainless steel |
Core Spring | Stainless steel |
Sealing & disc | CR (chloroprene) |
Diaphragm | NBR(nitrile/buna-n) |
Shading coil | Copper |
Connector | DIN43650A |
Voltage | DC: 24V, AC: 24V,48V,110V,230V |
Working Temperature | -20 to +85℃ |
Protection Class | IP65 |
Coil Insulation Class | F |
Working Pressure | 0.35-0.85Mpa |
Ordering Code | A | B | C | D | E | F | G | H | J | K | L | Weight |
SCG353A047 | 80 | 50 | 30 | 71 | 130 | 136 | 45 | G 3/8" | 131 | 160 | 178 | 1.40 |
SCG353A050 | 80 | 50 | 30 | 95 | 168 | 165 | 45 | G 3/8" | 165 | 210 | 227 | 2.90 |
SCG353A051 | 80 | 50 | 30 | 95 | 168 | 165 | 45 | G 3/8" | 165 | 210 | 227 | 2.60 |
SCG353.060 | 80 | 50 | 30 | 143 | 240 | 192 | 45 | G 1/2" | 165 | 258 | 275 | 4.10 |
After-sale Service
We can provide a series of after-sale service, such as product introduction, mounting, debugging, technical support and so on.
Warranty
All item Comes with Basic 3 Month Sellers Warranty, if item defective in 3 Month, We will offer replacement without extra Charger(including shipping fee)After we Receive the Defective item.
If item Defective after 3 Month, Buyers can still send it back, We will contact suppliers or Manufactory for Warranty. Buyers Might Need to pay the Shipping fee For resend the replaced item.
The installment introduction:
1. First, Confirm the pulse valve in good condition and then installed
2. Pulse valve will be installed directly the outer wall of flange of gas manifold. The spray pipe across the gas manifold. According to the drawing and manual, the pulse valve matching appropriate spray pipe and installation. To avoid the valve install in the air manifold bottom. If the pulse valve matched trachea and connector, the connector will be used for sealing purpose only. It can not as structural support components. It can not rely on the straight connector fixed spray torch and package. The spray pipe and air manifold must be fixed independent.
3. To tighten the hard nut, the maximum torque of 20 N*m.Tighten the trachea, torsion of 20 N*m.
4. The connection control wire needs connect of every electric control valve seat. Pay attention to the line adown to prevent rain waterproof. Or through the joint and nylon pipe, it will connect the pulse valve and electromagnetic assembly boxes of nylon pipe connection.
5. To ensure that provide compressed air clean and dry. The air manifold system provides moderate pressure and check for leaks installation. ( it can brush on soap and water, check whether the interface is bubble). Pressure was carried out on the air bag inflated (pressure of the valve is around 0.03 ~ 0. 86 mpa), recommend for air pressure 0.8 mpa maximum
6. Testing the pulse valve blowing, listening all the pilot valve whether it is normal operation and whether the pulse blowing sound is clear.
Company Details
Business Type:
Manufacturer
Year Established:
2000
Employee Number:
51~200
Ecer Certification:
Verified Supplier
FLY Automation Co.,Ltd was founded in 2010. We have many years experience in producing pneumatic components . Pneumatic components includes pneumatic fittings, pulse valves, water valves, induction coil, solenoid valves, manual valves, air control valves, angle seat valve, air preparation un... FLY Automation Co.,Ltd was founded in 2010. We have many years experience in producing pneumatic components . Pneumatic components includes pneumatic fittings, pulse valves, water valves, induction coil, solenoid valves, manual valves, air control valves, angle seat valve, air preparation un...
Get in touch with us
Leave a Message, we will call you back quickly!