Payment Terms | T/T, Western Union,Paypal |
Supply Ability | 100PCS Every month |
Delivery Time | 60-80 work days |
Packaging Details | carton |
Product brand name | SIRIUS |
Ambient temperature | -40 ... +80°C |
Protection level | IP20 |
Net Weight (kg) | 0.71KG |
Brand Name | SIEMENS |
Model Number | 3RW4027-1TB04 |
Place of Origin | CHINA |
View Detail Information
Explore similar products
SIEMENS 3 Way Plastic Contact Indicator Base 3SU1500-0AA10-0AA0
40mm Plastic Emergency Stop Button Tamperproof 3SU1000-1HB20-0AA0
6SL3210-5DE13-5UA0 85044095 Servo Drive SIEMENS V70
SIEMENS 6ES7315-2EH14-0AB0 Simatic S7 PLC - S7-300 CPU 315-2 PN/DP
Product Specification
Payment Terms | T/T, Western Union,Paypal | Supply Ability | 100PCS Every month |
Delivery Time | 60-80 work days | Packaging Details | carton |
Product brand name | SIRIUS | Ambient temperature | -40 ... +80°C |
Protection level | IP20 | Net Weight (kg) | 0.71KG |
Brand Name | SIEMENS | Model Number | 3RW4027-1TB04 |
Place of Origin | CHINA | ||
High Light | Siemens Sirius Soft Starter ,Thermistor Motor Protection Soft Starter ,3RW4027-1TB04 Motor Starter |
Product Description:
SIRIUS soft starter S0 32 A, 15 kW/400 V, 40 °C 200-480 V AC, 24 V AC/DC Screw terminals Thermistor motor protection.
General technical data | |
product brand name | SIRIUS |
product feature | |
● integrated bypass contact system | Yes |
● thyristors | Yes |
product function | |
● intrinsic device protection | Yes |
● motor overload protection | Yes |
● evaluation of thermistor motor protection | Yes |
● external reset | Yes |
● adjustable current limitation | Yes |
● inside-delta circuit | No |
product component motor brake output | No |
insulation voltage rated value | V 600 |
degree of pollution | 3, acc. to IEC 60947-4-2 |
reference code according to EN 61346-2 | Q |
reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750 | G |
Power Electronics | |
product designation | Soft starter |
operational current | |
● at 40 °C rated value | A 32 |
● at 50 °C rated value | A 29 |
● at 60 °C rated value | A 26 |
yielded mechanical performance for 3-phase motors | |
● at 230 V | |
— at standard circuit at 40 °C rated value | kW 7.5 |
● at 400 V | |
— at standard circuit at 40 °C rated value | kW 15 |
yielded mechanical performance [hp] for 3-phase AC | hp 7.5 |
motor at 200/208 V at standard circuit at 50 °C rated | |
value | |
operating frequency rated value | Hz 50 ... 60 |
relative negative tolerance of the operating frequency | -10% |
relative positive tolerance of the operating frequency | 10% |
operating voltage at standard circuit rated value | V 200 ... 480 |
relative negative tolerance of the operating voltage at | -15% |
standard circuit | |
relative positive tolerance of the operating voltage at | 10% |
standard circuit | |
10% | |
minimum load [%] % 20 | 20% |
adjustable motor current for motor overload | A 17 |
protection minimum rated value | |
continuous operating current [% of Ie] at 40 °C | 115% |
power loss [W] at operational current at 40 °C during | W 13 |
operation typical | |
Control circuit/ Control | |
type of voltage of the control supply voltage | AC/DC |
control supply voltage frequency 1 rated value | Hz 50 |
control supply voltage frequency 2 rated value | Hz 60 |
relative negative tolerance of the control supply | -10% |
voltage frequency | |
relative positive tolerance of the control supply | 10% |
voltage frequency | |
control supply voltage 1 at AC | |
● at 50 Hz rated value | V 24 |
● at 60 Hz rated value | V 24 |
relative negative tolerance of the control supply | -15% |
voltage at AC at 50 Hz | |
relative positive tolerance of the control supply | 10% |
voltage at AC at 50 Hz | |
relative negative tolerance of the control supply | -15% |
voltage at AC at 60 Hz | |
relative positive tolerance of the control supply | 10% |
voltage at AC at 60 Hz | |
control supply voltage 1 at DC rated value V 24 | -20% |
relative negative tolerance of the control supply | |
voltage at DC | |
relative positive tolerance of the control supply | 20% |
voltage at DC | |
display version for fault signal | red |
Mechanical data | |
size of engine control device | S0 |
width | mm 45 |
height | mm 125 |
depth | mm 155 |
fastening method | screw and snap-on mounting |
mounting position | With additional fan: With vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back Without additional fan: With vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° t |
required spacing with side-by-side mounting | |
● upwards | mm 60 |
● at the side | mm 15 |
● downwards | mm 40 |
wire length maximum | m 300 |
number of poles for main current circuit | 3 |
Connections/ Terminals | |
type of electrical connection | |
● for main current circuit | screw-type terminals |
● for auxiliary and control circuit | screw-type terminals |
number of NC contacts for auxiliary contacts | 0 |
number of NO contacts for auxiliary contacts | 2 |
number of CO contacts for auxiliary contacts | 1 |
type of connectable conductor cross-sections for | |
main contacts for box terminal using the front | |
clamping point | |
● solid | 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), max. 1x 10 mm² |
● finely stranded with core end processing | 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²) |
type of connectable conductor cross-sections at AWG | |
cables for main contacts for box terminal | |
● using the front clamping point | 1x 8, 2x (16 ... 10) |
type of connectable conductor cross-sections for | |
auxiliary contacts | |
● solid | 2x (0.5 ... 2.5 mm²) |
● finely stranded with core end processing | 2x (0.5 ... 1.5 mm²) |
type of connectable conductor cross-sections at AWG | |
cables | |
● for auxiliary contacts | 2x (20 ... 14) |
● for auxiliary contacts finely stranded with core end processing | 2x (20 ... 16) |
Ambient conditions | |
installation altitude at height above sea level | m 5 000 |
environmental category | |
● during transport according to IEC 60721 | 2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m) |
● during storage according to IEC 60721 | 1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4 |
● during operation according to IEC 60721 | 3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 |
ambient temperature | |
● during operation | °C -25 ... +60 |
● during storage | °C -40 ... +80 |
derating temperature | °C 40 |
protection class IP on the front according to IEC 60529 | IP20 |
touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front |
UL/CSA ratings | |
yielded mechanical performance [hp] for 3-phase AC motor | |
● at 220/230 V | |
— at standard circuit at 50 °C rated value hp 7.5 | hp 7.5 |
● at 460/480 V | |
— at standard circuit at 50 °C rated value | hp 20 |
contact rating of auxiliary contacts according to UL | B300 / R300 |
Dimensional drawings:
Company Details
Business Type:
Manufacturer
Year Established:
2000
Employee Number:
51~200
Ecer Certification:
Verified Supplier
FLY Automation Co.,Ltd was founded in 2010. We have many years experience in producing pneumatic components . Pneumatic components includes pneumatic fittings, pulse valves, water valves, induction coil, solenoid valves, manual valves, air control valves, angle seat valve, air preparation un... FLY Automation Co.,Ltd was founded in 2010. We have many years experience in producing pneumatic components . Pneumatic components includes pneumatic fittings, pulse valves, water valves, induction coil, solenoid valves, manual valves, air control valves, angle seat valve, air preparation un...
Get in touch with us
Leave a Message, we will call you back quickly!