China factories

China factory - QINGDAO ENNENG MOTOR CO.,LTD.

QINGDAO ENNENG MOTOR CO.,LTD.

  • China,Qingdao ,Shandong
  • Site Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Brushless AC 3 Phase PMSM Motor Variable Frequency Synchronous Motor
China Brushless AC 3 Phase PMSM Motor Variable Frequency Synchronous Motor

  1. China Brushless AC 3 Phase PMSM Motor Variable Frequency Synchronous Motor

Brushless AC 3 Phase PMSM Motor Variable Frequency Synchronous Motor

  1. MOQ: 1 set
  2. Price: USD 500-5000/set
  3. Get Latest Price
Payment Terms L/C, T/T
Supply Ability 20000 sets/year
Delivery Time 15-120 days
Packaging Details seaworthy packing
Name Brushless AC 3 Phase PMSM motor
Current AC
Material Rare Earth NdFeB
Power Range 5.5-3000kw
Installation IMB3 IMB5 IMB35
Phase 3 phase
Service ODM, OEM
Applications belt conveyors
Features High efficiency, energy saving, low maintenance
Protection Grade IP54 IP55 IP68
Brand Name ENNENG
Model Number PMM
Certification CE,UL
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 20000 sets/year
Delivery Time 15-120 days Packaging Details seaworthy packing
Name Brushless AC 3 Phase PMSM motor Current AC
Material Rare Earth NdFeB Power Range 5.5-3000kw
Installation IMB3 IMB5 IMB35 Phase 3 phase
Service ODM, OEM Applications belt conveyors
Features High efficiency, energy saving, low maintenance Protection Grade IP54 IP55 IP68
Brand Name ENNENG Model Number PMM
Certification CE,UL Place of Origin China
High Light Brushless 3 Phase PMSM MotorUL 3 Phase PMSM Motor3 Phase AC Synchronous Motor

Brushless AC 3 Phase Variable Frequency Drive PMSM Motor For Belt Conveyor

 

What Is The Permanent Magnet Synchronous Motor?

 

The Permanent Magnet Synchronous Motor (PMSM) is a type of electric motor that operates using permanent magnets embedded in its rotor. It is also sometimes referred to as a brushless AC motor or a synchronous permanent magnet motor.

 

In a PMSM, the stator (the stationary part of the motor) contains a series of coils that are energized in a sequence to create a rotating magnetic field. The rotor (the rotating part of the motor) contains a series of permanent magnets that are arranged to produce a magnetic field that interacts with the magnetic field produced by the stator.

 

As the two magnetic fields interact, the rotor rotates, producing mechanical energy that can be used to power machinery or other devices. Because the permanent magnets in the rotor provide a strong, constant magnetic field, PMSMs are highly efficient and require less energy to operate than other types of electric motors.

 

PMSMs are used in a wide variety of applications, including electric vehicles, industrial machinery, and household appliances. They are known for their high efficiency, low maintenance requirements, and precise control, which makes them a popular choice for many different types of systems.

 

Working of Permanent Magnet Synchronous Motor:

 

The working of the permanent magnet synchronous motor is very simple, fast, and effective when compared to conventional motors. The working of PMSM depends on the rotating magnetic field of the stator and the constant magnetic field of the rotor. The permanent magnets are used as the rotor to create constant magnetic flux, and operate and lock at synchronous speed. These types of motors are similar to brushless DC motors.

 

The phasor groups are formed by joining the windings of the stator with one another. These phasor groups are joined together to form different connections like a star, Delta, and double and single phases. To reduce harmonic voltages, the windings should be wound shortly with each other.

 

When the 3-phase AC supply is given to the stator, it creates a rotating magnetic field and the constant magnetic field is induced due to the permanent magnet of the rotor. This rotor operates in synchronism with the synchronous speed. The whole working of the PMSM depends on the air gap between the stator and rotor with no load.

 

If the air gap is large, then the windage losses of the motor will be reduced. The field poles created by the permanent magnet are salient. The permanent magnet synchronous motors are not self-starting motors. So, it is necessary to control the variable frequency of the stator electronically.

 

Detailed pictures

Differences Between The Permanent Magnet Motor And Asynchronous Motor

 

01. Rotor Structure

Asynchronous motor: The rotor consists of an iron core and a winding, mainly squirrel-cage and wire-wound rotors. A squirrel-cage rotor is cast with aluminum bars. The magnetic field of the aluminum bar cutting the stator drives the rotor.

 

PMSM Motor: The permanent magnets are embedded in the rotor magnetic poles, and are driven to rotate by the rotating magnetic field generated in the stator according to the principle of magnetic poles of the same phase attracting different repulsions.

 

02. Efficiency

Asynchronous motors: Need to absorb current from the grid excitation, resulting in a certain amount of energy loss, motor reactive current, and low power factor.

 

PMSM Motor: The magnetic field is provided by permanent magnets, the rotor does not need exciting current, and the motor efficiency is improved.

 

03. Volume And Weight

The use of high-performance permanent magnet materials makes the air gap magnetic field of permanent magnet synchronous motors larger than that of asynchronous motors. The size and weight are reduced compared to asynchronous motors. It will be one or two frame sizes lower than asynchronous motors.

 

04. Motor Starting Current

Asynchronous motor: It is directly started by power frequency electricity, and the starting current is large, which can reach 5 to 7 times the rated current, which has a great impact on the power grid in an instant. The large starting current causes the leakage resistance voltage drop of the stator winding to increase, and the starting torque is small so heavy-duty starting cannot be achieved. Even if the inverter is used, it can only start within the rated output current range.

 

PMSM Motor: It is driven by a dedicated controller, which lacks the rated output requirements of the reducer. The actual starting current is small, the current is gradually increased according to the load, and the starting torque is large.

 

05. Power Factor

Asynchronous motors have a low power factor, they must absorb a large amount of reactive current from the power grid, the large starting current of asynchronous motors will cause a short-term impact on the power grid, and long-term use will cause certain damage to the power grid equipment and transformers. It is necessary to add power compensation units and perform reactive power compensation to ensure the quality of the power grid and increase the cost of equipment use.

 

There is no induced current in the rotor of the permanent magnet synchronous motor, and the power factor of the motor is high, which improves the quality factor of the power grid and eliminates the need to install a compensator.

 

06. Maintenance

Asynchronous motor + reducer structure will generate vibration, heat, high failure rate, large lubricant consumption, and high manual maintenance cost; it will cause certain downtime losses.

 

The three-phase Permanent magnet synchronous motor drives the equipment directly. Because the reducer is eliminated, the motor output speed is low, mechanical noise is low, mechanical vibration is small, and the failure rate is low. The entire drive system is almost maintenance-free.

 

EMF and Torque Equation

 

In a synchronous machine, the average EMF induced per phase is called dynamic induces EMF in a synchronous motor, the flux cut by each conductor per revolution is Pϕ Weber

Then the time taken to complete one revolution is 60/N sec

 

The average EMF induced per conductor can be calculated by using

 

( PϕN / 60 ) x Zph = ( PϕN / 60 ) x 2Tph

 

Where Tph = Zph / 2

 

Therefore, the average EMF per phase is,

 

= 4 x ϕ x Tph x PN/120 = 4ϕfTph

Where Tph = no. Of turns connected in series per phase

 

ϕ = flux/pole in Weber

 

P= no. Of poles

 

F= frequency in Hz

 

Zph= no. Of conductors connected in series per phase. = Zph/3

 

The EMF equation depends on the coils and the conductors on the stator. For this motor, the distribution factor Kd and pitch factor Kp are also considered.

 

Hence, E = 4 x ϕ x f x Tph xKd x Kp

 

The torque equation of a permanent magnet synchronous motor is given as,

 

T = (3 x Eph x Iph x sinβ) / ωm

 

 

Permanent magnet AC (PMAC) motors have a wide range of applications including:

 

Industrial Machinery: PMAC motors are used in a variety of industrial machinery applications, such as pumps, compressors, fans, and machine tools. They offer high efficiency, high power density, and precise control, making them ideal for these applications.

 

Robotics: PMAC motors are used in robotics and automation applications, where they offer high torque density, precise control, and high efficiency. They are often used in robotic arms, grippers, and other motion control systems.

 

HVAC Systems: PMAC motors are used in heating, ventilation, and air conditioning (HVAC) systems, where they offer high efficiency, precise control, and low noise levels. They are often used in fans and pumps in these systems.

 

Renewable Energy Systems: PMAC motors are used in renewable energy systems, such as wind turbines and solar trackers, where they offer high efficiency, high power density, and precise control. They are often used in the generators and tracking systems in these systems.

 

Medical Equipment: PMAC motors are used in medical equipment, such as MRI machines, where they offer high torque density, precise control, and low noise levels. They are often used in the motors that drive the moving parts in these machines.

 

IPM VS SPM

 

A permanent magnet motor (also called PM) can be separated into two main categories: Interior Permanent Magnet (IPM) and Surface Permanent Magnet (SPM). Both types generate magnetic flux by the permanent magnets affixed to or inside of the rotor.

 

SPM

SURFACE PERMANENT MAGNET

A type of motor in which permanent magnets are attached to the rotor circumference.

SPM motors have magnets affixed to the exterior of the rotor surface, their mechanical strength is so weaker than the IPM ones. The weakened mechanical strength limits the motor’s maximum safe mechanical speed. In addition, these motors exhibit very limited magnetic saliency (Ld ≈ Lq). Inductance values measured at the rotor terminals are consistent regardless of the rotor position. Because of the near unity saliency ratio, SPM motor designs rely significantly, if not completely, on the magnetic torque component to produce torque.

 

IPM

INTERIOR PERMANENT MAGNET

A type of motor that has a rotor embedded with permanent magnets is called IPM.

IPM motors have a permanent magnet embedded into the rotor itself. Unlike their SPM counterparts, the location of the permanent magnets makes IPM motors very mechanically sound, and suitable for operating at very high speeds. These motors also are defined by their relatively high magnetic saliency ratio (Lq > Ld). Due to their magnetic saliency, an IPM motor has the ability to generate torque by taking advantage of both the magnetic and reluctance torque components of the motor.

 

Advantages Of Rare-earth Permanent Magnet Motors

High efficiency: The efficiency curve of the asynchronous motor generally falls faster under 60% of the rated load, and the efficiency is very low at light load. The efficiency curve of the rare earth permanent magnet motor is high and flat, and it is in the high efficiency area at 20%~120% of the rated load.

 

High power factor: The measured value of the power factor of the rare earth permanent magnet synchronous motor is close to the limit value of 1.0. The power factor curve is as high and flat as the efficiency curve. The power factor is high. Low-voltage reactive power compensation is not required and the power distribution system capacity is fully utilized.

 

Stator current is small: The rotor has no excitation current, the reactive power is reduced, and the stator current is significantly reduced. Compared with the asynchronous motor of the same capacity, the stator current value can be reduced by 30% to 50%. At the same time, because the stator current is greatly reduced, the motor temperature rise is reduced, and the bearing grease and bearing life are extended.

 

High out-of-step torque and pull-in torque: Rare earth permanent magnet synchronous motors have higher out-of-step torque and pull-in torque, which makes the motor have higher load capacity and can be smoothly pulled into synchronization.

 

Disadvantages Of Rare-earth Permanent Magnet Motors

High cost: Compared with the asynchronous motor of the same specification, the air gap between the stator and the rotor is smaller, and the processing accuracy of each component is high; the rotor structure is more complicated and the price of rare earth magnetic steel material is high; therefore, the motor manufacturing cost is high, which is common for asynchronous motors About 2 times.

 

Large impact at full power start: When starting at full pressure, the synchronous speed can be drawn in a very short time. The mechanical shock is large. The starting current is more than 10 times the rated current. The impact on the power supply system is large, requiring a large capacity of the power supply system.

 

Rare-earth magnet steel is easy to demagnetize: When the permanent magnet material is subjected to vibration, high temperature and overload current, its magnetic permeability may decrease, or a demagnetization phenomenon occurs, which reduces the performance of the permanent magnet motor.

How long is the life of rare earth permanent magnet motor? Will the magnetism weaken over time?

The service life of the permanent magnet motor is generally 15-20 years, and the service life of the motor mainly depends on the maintenance of the user.

 

In addition, the quality of the permanent magnet motor's use environment, and the factors such as electricity, magnetism, heat, vibration, and other factors that the motor receives during use will affect the life of the permanent magnet synchronous motor!

 

General magnets have a service life. When used for a certain number of years, the magnetism will weaken, but the magnetic properties of NdFeB permanent magnet materials change very little with time, and rare earth permanent magnets are within the design life of the motor (10-20 years).

The magnetic performance attenuation is less than 3%. Under the existing motor design and electronic control technology, it has little impact on the overall performance of the motor.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2014

  • Total Annual:

    2,000,000.00-4,000,000.00

  • Employee Number:

    100~200

  • Ecer Certification:

    Site Member

The value of Enneng is Technology is how we do things. People are why we do things.   As a leading manufacturer of permanent magnet AC motors and generators, Enneng is committed to providing the best solutions for our customers while also prioritizing energy savings and low carbon emissio... The value of Enneng is Technology is how we do things. People are why we do things.   As a leading manufacturer of permanent magnet AC motors and generators, Enneng is committed to providing the best solutions for our customers while also prioritizing energy savings and low carbon emissio...

+ Read More

Get in touch with us

  • Reach Us
  • QINGDAO ENNENG MOTOR CO.,LTD.
  • No. 18, Xinye Road, High-Tech Zone, Qingdao,Shandong, China
  • https://www.pmacmotor.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement