Payment Terms | T/T |
Supply Ability | 1piece in stock |
Delivery Time | 3 day |
Packaging Details | 80*50*50mm |
System | gold-plated contacts |
Weight[g] | 242.15 |
Brand Name | IFM |
Model Number | PN3594 |
Certification | 3C |
Place of Origin | GERMANY |
View Detail Information
Explore similar products
IFM Inductive Full-metal Sensor II502A IIK3010-BPKG/AM/US104DPS/3G/3D Connector
Inductive Sensor IIS206 IIKC015BASKG/2LED Flush Mountable Connector 1 X M12
IIS238 - Inductive Sensor - Ifm - Ifm Electronic For Industrial , Mobile ,
IFM Electronic Gmbh Inductive Sensor IM0010 Non-flush Mountable
Product Specification
Payment Terms | T/T | Supply Ability | 1piece in stock |
Delivery Time | 3 day | Packaging Details | 80*50*50mm |
System | gold-plated contacts | Weight[g] | 242.15 |
Brand Name | IFM | Model Number | PN3594 |
Certification | 3C | Place of Origin | GERMANY |
Application | ||||||||||||||
Measuring element | ceramic-capacitive pressure measuring | cell | ||||||||||||
Media | group 2 fluids according to the Pressure Equipment Directive (PED) | |||||||||||||
Conditionally suitable for | group 1 fluids on request | |||||||||||||
Medium temperature [°C] | -25...80 | |||||||||||||
Pressure rating | 75 bar | 1087 psi | 7.5 MPa | |||||||||||
Min. bursting pressure | 150 bar | 2175 psi | 15 MPa | |||||||||||
Vacuum resistance | [mbar] | -1000 | ||||||||||||
Type of pressure | relative pressure | |||||||||||||
Electrical data | ||||||||||||||
Operating voltage [V] | 18...30 DC; (according to EN 50178 SELV/PELV) | |||||||||||||
Current consumption | [mA] | < 35 | ||||||||||||
Min. insulation resistance [MΩ] | 100; (500 V DC) | |||||||||||||
Protection class | III | |||||||||||||
Reverse polarity protection | yes | |||||||||||||
Power-on delay time | [s] | 0.3 | ||||||||||||
Integrated watchdog | yes | |||||||||||||
Inputs / outputs | ||||||||||||||
Number of inputs and outputs | Number of digital outputs: 1; Number of analog outputs: 1 | |||||||||||||
![]() | ||||||||||||||
PN3594 | ||||||||||||||
Pressure sensor with display | ||||||||||||||
PN-010-REG14-MFRKG/US/ /V | ||||||||||||||
Outputs | ||||||||||||||
Total number of outputs | 2 | |||||||||||||
Output signal | switching signal; analog signal; IO-Link; (configurable) | |||||||||||||
Electrical design | PNP | |||||||||||||
Number of digital outputs | 1 | |||||||||||||
Output function | normally open / closed; (configurable) | |||||||||||||
Max. voltage drop switching output DC | [V] | 2.5 | ||||||||||||
Permanent current rating of switching output DC | [mA] | 150; (200 (...60 °C) 250 (...40 °C)) | ||||||||||||
Switching frequency DC | [Hz] | < 170 | ||||||||||||
Number of analog outputs | 1 | |||||||||||||
Analog current output | [mA] | 4...20; (0 bar = 4 mA; 10 bar = 20 mA) | ||||||||||||
Max. load | [Ω] | 500 | ||||||||||||
Analog voltage output | [V] | 0...10; (0 bar = 0 V; 10 bar = 10 V) | ||||||||||||
Min. load resistance | [Ω] | 2000 | ||||||||||||
Short-circuit protection | yes | |||||||||||||
Type of short-circuit protection | yes (non-latching) | |||||||||||||
Overload | protection | yes | ||||||||||||
Measuring/setting range | ||||||||||||||
Measuring range | -1...10 bar | -14.5...145 psi | -0.1...1 MPa | |||||||||||
Set point SP | -0.9...10 bar | -13.5...145 psi | -0.09...1 MPa | |||||||||||
Reset point rP | -0.95...9.95 bar | -14...144.5 psi | > -0.095 MPa | |||||||||||
Insteps of | 0.05 bar | 0.5 psi | 0.005 MPa | |||||||||||
Accuracy / deviations | ||||||||||||||
Switch point accuracy | < ± 0,5 | |||||||||||||
[% of the span] | ||||||||||||||
Repeatability | [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) | ||||||||||||
Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) | |||||||||||||
Hysteresis deviation [% of the span] | < ± 0,25 | |||||||||||||
Long-term stability [% of the span] | < ± 0,05; (per 6 months) | |||||||||||||
Temperature coefficient zero point [% of the span / 10 K] | < ± 0,2; (-0...80 °C) | |||||||||||||
Temperature coefficient span [% of the span / 10 K] | < ± 0,2; (-0...80 °C) | |||||||||||||
![]() | ||||||||||||||
PN3594 | ||||||||||||||
Pressure sensor with display | ||||||||||||||
PN-010-REG14-MFRKG/US/ /V | ||||||||||||||
Reaction times | ||||||||||||||
Response time | [ms] | < 3 | ||||||||||||
Delay time programmable dS, dr | [s] | 0...50 | ||||||||||||
Damping for the switching output dAP | [s] | 0...4 | ||||||||||||
Damping for the analog output dAA | [s] | 0...4 | ||||||||||||
Max. response time analog output | [ms] | 3 | ||||||||||||
Software / programming | ||||||||||||||
Parameter setting options | hysteresis / window; normally open / closed; switch-on/ switch-off delay; Damping; Display unit; current/voltage output | |||||||||||||
Interfaces | ||||||||||||||
Communication interface | IO-Link | |||||||||||||
Transmission type | COM2 | |||||||||||||
IO-Link revision | 1.1 | |||||||||||||
SDCI standard | IEC 61131-9 | |||||||||||||
IO-Link device ID | 431 d / 00 01 afh | |||||||||||||
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | |||||||||||||
SIO mode | yes | |||||||||||||
Required master port class | A | |||||||||||||
Process data analogue | 1 | |||||||||||||
Process data binary | 1 | |||||||||||||
Min. process cycle time [ms] | 2.3 | |||||||||||||
Operating conditions | ||||||||||||||
Ambient temperature [°C] | -25...80 | |||||||||||||
Storage temperature Protection | [°C] | -40...100 IP 65; IP 67 | ||||||||||||
Tests / approvals | ||||||||||||||
EMC | DIN EN 61000-6-2 | |||||||||||||
DIN EN 61000-6-3 | ||||||||||||||
Shock resistance | DIN EN 60068-2-27 | 50 g (11 ms) | ||||||||||||
Vibration resistance | DIN EN 60068-2-6 | 20 g (10...2000 Hz) | ||||||||||||
MTTF [years] | 181 | |||||||||||||
UL approval | UL approval number | J004 | ||||||||||||
Pressure equipment directive | sound engineering practice | |||||||||||||
![]() | ||||||||||||||
PN3594 | ||||||||||||||
Pressure sensor with display | ||||||||||||||
PN-010-REG14-MFRKG/US/ /V | ||||||||||||||
Mechanical data | ||||||||||||||
Weight | [g] | 281.5 | ||||||||||||
Material | stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC | |||||||||||||
Materials (wetted parts) | stainless steel (1.4404 / 316L); Al2O3 (ceramics); FKM | |||||||||||||
Min. pressure cycles | 100 million | |||||||||||||
Tightening torque | [Nm] | 25...35; (recommended tightening torque; Depends on lubrication, sealand pressure rating) | ||||||||||||
Process connection | threaded connection G 1/4 external thread (DIN EN ISO 1179-2); Internal threadM5 | |||||||||||||
Process connection sealing | FKM (to DIN 3869) | |||||||||||||
Restrictor element integrated | no (can be retrofitted) | |||||||||||||
Displays / operating elements | ||||||||||||||
Display unit | 3 x LED, green (bar, psi, MPa) | |||||||||||||
Display | Switching status | 1 x LED, yellow | ||||||||||||
Measured values | alphanumeric display, red/green 4-digit | |||||||||||||
Remarks | ||||||||||||||
Pack quantity | 1 pcs. | |||||||||||||
Electrical connection |
Company Details
Business Type:
Trading Company
Year Established:
2017
Total Annual:
300000-800000
Employee Number:
12~20
Ecer Certification:
Verified Supplier
Xiamen Zhicheng Automation Technology Co., Ltd Xiamen Zhicheng Automation Technology Co., Ltd. Still Working And Able To Shipping Worldwide.We Are The Supplier For Industrial Automation Spare Parts.we Specialize In Plc Module, Dcs Card Pieces, Esd System C... Xiamen Zhicheng Automation Technology Co., Ltd Xiamen Zhicheng Automation Technology Co., Ltd. Still Working And Able To Shipping Worldwide.We Are The Supplier For Industrial Automation Spare Parts.we Specialize In Plc Module, Dcs Card Pieces, Esd System C...