China factories

China factory - Suzhou Delfino Environmental Technology Co., Ltd.

Suzhou Delfino Environmental Technology Co., Ltd.

  • China,Suzhou ,Jiangsu
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All
China Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All

  1. China Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All
  2. China Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All

Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All

  1. MOQ: Negotiable
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T
Delivery Time 1-45 work days
Packaging Details Carton
Product Name Hydrogen peroxide sensor
Product Model WP10
Measuring range: 0~200/2000/20000 ppm
Pressure Range 0 ~ 5 (Flow cell)
Temperature Range 0 ~ 40 ℃
Response Time T90: approx. 8 min
Flow Rate 15-30 l/h (33 – 66 cm/s)
Brand Name Daruifuno
Model Number WP10
Certification CE, ISO
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Delivery Time 1-45 work days
Packaging Details Carton Product Name Hydrogen peroxide sensor
Product Model WP10 Measuring range: 0~200/2000/20000 ppm
Pressure Range 0 ~ 5 (Flow cell) Temperature Range 0 ~ 40 ℃
Response Time T90: approx. 8 min Flow Rate 15-30 l/h (33 – 66 cm/s)
Brand Name Daruifuno Model Number WP10
Certification CE, ISO Place of Origin China

Chemicals High Tolerance Two-Electrode System Hydrogen Peroxide Sensor For All Water Treatment

 

The two-electrode system membrane hydrogen peroxide sensor WP10 has the following features and advantages, making it an excellent performer in the field of water treatment:

 

Features


Mechanically strong membrane system

The sensor adopts a high-strength membrane system design, which can operate stably in harsh environments and effectively prevent damage.


Surfactant tolerance

It has high tolerance to surfactants (such as detergents or chemical reagents) and is suitable for a variety of water quality conditions.


High tolerance to chemicals

It can resist the influence of a variety of chemicals (including strong oxidants or other corrosive substances) to ensure long-term stability.


Applicable temperature range

The working water temperature can reach up to 45℃, which meets most industrial water treatment needs.


Multiple optional ranges

Three ranges are available: 0200 ppm, 02000 ppm, and 0~20000 ppm, which meet different needs from trace detection to high concentration detection.


Advantages


Accurate measurement

Using a two-electrode system, it has high sensitivity and accuracy and can quickly respond to changes in hydrogen peroxide concentration.
Low maintenance requirements

Durable design and stable operation reduce maintenance frequency and cost.


Widely used

Applicable to various water treatment processes, including drinking water, industrial wastewater, sewage and circulating cooling water.


Easy to operate

Modular design and user-friendly interface for easy installation and use.


High stability

Not affected by water flow fluctuations, capable of long-term continuous operation, reducing the risk of instrument drift and data errors.

 

Two-electrode system, used in all water treatment, mechanically strong membrane system, resistant to surfactants, high resistance to chemicals, maximum water temperature: 45°C, optional range 0~200/2000/20000 ppm​

 

 

Specifications

 

 

 

 

 

 

 

WP10
 

 Indicator   Hydrogen peroxide

 

Application

All kinds of water treatment, also sea water, especially for high H2O2- concentrations.

The membrane system is mechanical resistant.

The membrane system is highly resistant to surfactants (tensides).

 Measuring system   Membrane covered, amperometric 2-electrode system.

 

 

 

 

 

Electronic

Analog version:    - voltage output

- not galvanically isolated electronics

- analog internal data processing

                              - output signal: analog (analog-out/analog)

Digital version:      - electronic is completely galvanically isolated

                              - digital internal data processing

 - output signal: analog (analog-out/digital)

   or

                                                       digital (digital-out/digital)

mA-version:            - current output analog

  - not galvanically isolated electronics

  - output signal: analog (analog-out/analog)

 

Information about the measuring range

The actual slope of a sensor can vary production-related between 65% and 150% of the nominal slope

Note: With a slope > 100% the measuring range is reduced accordingly.

          (Ex.: 150% slope → 67% of the specified measuring range)

 

Working temperature

Measuring water temperature:    0 … +45 °C

                                                   (no ice crystals in the measuring water)

    Ambient temperature:                  0 … +55 °C

 

Temperature compensation

Automatically, by an integrated temperature sensor Response time t90 = approx. 8 min.

Max. change in temperature: 5 °C per hour, sudden temperature changes must be avoided

 

 

 

Max. allowed working pressure

Operation without retaining ring:

- 0.5 bar

- no pressure impulses and/or vibrations

 

Operation with retaining ring in flow cell:

- 1.0 bar,

- no pressure impulses and/or vibrations

  (see option 1)

Flow rate

(Incoming flow velocity)

  Approx. 15-30 l/h (33 – 66 cm/s) in flow cell, small flow rate dependence is given
 pH-range   pH 2 – pH 11

 

 

 

 

WP10

  Run-in time  First start-up approx. 5 h
  Response time  T90: approx. 8 min.

Accuracy

after calibration at repeatability conditions (25°C, pH 7.2 in drinking water) of the upper full scale

  - Measuring range 200 ppm:  at 40 ppm <2%

                                                  at 160 ppm <2%

  - Measuring range 2000 ppm: at 400 ppm <0,5%

at 1600 ppm <2%

  Zero point adjustment   Not necessary
  calibration   At the device, by analytical determination

 

interferences

Cl2: must not be present

PAA: must not be present

O3: must not be present

Sulfides: contaminate the measuring system

Phenol: aqueous solution >3 % phenol, destroys the membrane system

  Absence of the disinfectant   Max. 24 h

 

Connection

mV version:               5-pole M12, plug-on flange

Modbus version:        5-pole M12, plug-on flange

4-20 mA version:       2-pole terminal

                                   or

                                   5-pole M12, plug-on flange

  Max. length of sensor   cable (depending on   internal signal processing)  Analog   < 30 m
 Digital

> 30 m are permissible

Maximum cable length depends on application

  Protection type

5-pole M12 plug-on flange:        IP68

2-pole terminal with mA-hood:   IP65

  Material   Elastomer membrane, PVC-U, stainless steel 1.4571

 

 

Size

Diameter:                              approx. 25 mm

Length: mV version               approx. 190 mm (analog signal processing)

    approx.. 205 mm (digital signal processing)

Modbus version       approx. 205 mm

4-20 mA version       approx. 220 mm (2-pole-terminal)

     approx. 190 mm (5-pole-M12)

  Transport   +5 … +50 °C (Sensor, electrolyte, membrane cap)

 

 

Storage

  Sensor: dry and without electrolyte no limit at +5 … +40 °C

Electrolyte:     in original bottle protected from sunlight at +5 … +35 °C min.

1 year or until specified EXP-Date

Membrane cap: in original packing no limit at +5 … +40 °C

                          (used membrane caps can not be stored)

 

 

 

 

WP10

 

maintenance

Regularly control of the measuring signal, min. once a week

The following specifications highly depend on the water quality:

Change of the membrane cap:    once a year

Change of the electrolyte:            every 3 - 6 months

  

 

 

 

 

Option 1: Retaining ring

  - When operating with pressures   >0.5 bar in flow cell

  - Dimensions retaining ring 29 x   23.4 x 2.5 mm, slitted,   PETP

  - Different positions for   groove selectable (on request)

                                

 

 

Technical Data

 

1. WP10 (Analog output, analog internal signal processing)

A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation.

 

Measuring range resolution

Output

Output resistance

Nominal slope Voltage supply Connection
WP10H-M12 0.5…200 ppm 0.1 ppm

0…-2000 mV

 

1 kΩ

-10 mV/ppm

±5 - ±15 VDC

10 mA

5-pole M12 plug-on flange

 

Function of wires:

PIN1: measuring signal PIN2: +U

PIN3: -U

PIN4: signal GND

PIN5: n. c.

WP10N-M12 5…2000 ppm 1 ppm -1 mV/ppm
WP10L-M12 0.005…2 % (20000 ppm)

0.001 %

(10 ppm)

-1000mV/%

(-0.1 mV/ppm)

 WP10-20%-M12

0.05… 20%

(200000 ppm)

0.01 %

(100 ppm)

-100 mV/%

(-0.01 mV/ppm)

(Subject to technical changes!)

2. WP10 (analog output, digital signal processing)

Analog-out / digital

The power supply is galvanically isolated inside of the sensor.

The output signal is galvanically isolated too, that means potential-free.

 

Measuring range Resolution Output Output resistance Nominal Slope Power supply Connection
WP10H-An-M12 0.5… 200.0 ppm 0.1 ppm


analog
0…-2 V (max.
-2.5 V)
1 kΩ

-10 mV/ppm 9-30 VDC
approx.
20-56 mA

 5-pole M12 plug-on   flange

 

Function of wires:

PIN1: measuring signal PIN2: +U

PIN3: power GND

PIN4: signal GND

PIN5: n. c.

WP10N-An-M12 .50… 2000 ppm 1 ppm -1 mV/ppm
WP10L-An-M12 0.005… 2 %
(20000 ppm)
0.001 %
(10 ppm)
-1000 mV/%
(-0.1 mV/ppm)
WP10-20%-An-M12

0.05… 20 %

(200000 ppm)

0.01 %

(100 ppm)

-100 mV/%

(-0.01 mV/ppm)

WP10H-Ap-M12 0.5… 200.0 ppm 0.1 ppm



analog
0…+2 V (max.
+2.5 V)
1 kΩ

+10 mV/ppm
WP10N-Ap-M12 5… 2000 ppm 1 ppm +1 mV/ppm
WP10L-Ap-M12 0.005… 2 %
(20000 ppm)
0.001 %
(10 ppm)
+1000 mV/%
(+0.1 mV/ppm)
WP10-20%-Ap-M12 0.05… 20 %
(200000 ppm)
0.01 %
(100 ppm)
+100 mV/%
(+0.01 mV/ppm)

 

(Subject to technical changes!)

3. WP10 (digital output, digital signal processing)

The power supply is galvanically isolated inside of the sensor.

The output signal is galvanically isolated too, that means potential-free.

 

 

Measuring range Resolution

Output

Output resistance

Power supply Connection
WP10H-M0c 0.5… 200.0 ppm 0.1 ppm

Modbus RTU


There are no terminating resistors in the sensor.

 

9-30 VDC

 

approx. 20-56 mA

 

5-pole M12 plug-on flange

 

 Function of wires:

 PIN1: reserved

 PIN2: +U

PIN3: power GND

PIN4: RS485B

PIN5: RS485A

WP10N-M0c 5… 2000 ppm 1 ppm
WP10L-M0c

0.005… 2 %

(20000 ppm)

0.001 %

(10 ppm)

WP10-20%-M0c

0.05… 20 %

(200000 ppm)

0.01 %

(100 ppm)

(Subject to technical changes!)

 

4. WP10 4-20 mA (analog output, analog internal signal processing)

A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation.

4.1 Electrical connection: 2 pole terminal clamp

 

Measuring range resolution Output Output resistance Nominal slope Voltage supply Connection
WP10MA-200 0.5… 200.0 ppm 0.1 ppm

 

4…20 mA

uncalibrated
0.08 mA/ppm

 

12…30 VDC


RL 50Ω…RL 900Ω

2-pole terminal

(2 x 1 mm²)

 

Recommended: Round cable

Æ 4 mm

2 x 0.34 mm²

WP10MA-2000 5… 2000 ppm 1 ppm 0.008 mA/ppm
WP10MA-2%

0.005… 2 %

(20000 ppm)

0.001 %

(10 ppm)

8 mA/%

(0.0008 mA/ppm)

WP10MA-5%

0.05… 5 %

(50000 ppm)

0.01 %

(100 ppm)

3.2 mA/%

(0.00032 mA/ppm)

WP10MA-10% 0.05… 10 %
(100000 ppm)
0.01 %
(100 ppm)
1.6 mA/%
(0.00016 mA/ppm)
WP10MA-20% 0.05… 20 %
(200000 ppm)
0.01 %
(100 ppm)
0.8 mA/%
(0.00008 mA/ppm)

(Subject to technical changes!)

 

4.2 Electrical connection: 5 pole M12 plug-on flange

 

 

Measuring range resolution Output Output resistance Nominal slope Voltage supply Connection
WP10MA-200-M12 0.5… 200.0 ppm 0.1 ppm

 

4…20 mA


uncalibrated
0.08 mA/ppm

12…30 VDC


RL 50Ω…RL 900Ω

 5-pole M12 plug-on   flange

 

Function of wires: PIN1: n. c.

PIN2: +U

PIN3: -U

PIN4: n c.

PIN5: n. c.

WP10MA-2000-M12 5… 2000 ppm 1 ppm 0.008 mA/ppm
WP10MA-2%-M12

0.005… 2 %

(20000 ppm)

0.001 %

(10 ppm)

8 mA/%

(0.0008 mA/ppm)

WP10MA-5%-M12

0.05… 5 %

(50000 ppm)

0.01 %

(100 ppm)

3.2 mA/%

(0.00032 mA/ppm)

WP10MA-10%-M12 0.05… 10 %
(100000 ppm)
0.01 %
(100 ppm)
1.6 mA/%
(0.00016 mA/ppm)
WP10MA-20%-M12 0.05… 20 %
(200000 ppm)
0.01 %
(100 ppm)
0.8 mA/%
(0.00008 mA/ppm)

(Subject to technical changes!)

 

Spare Parts

 

Type Membrane cap Electrolyte Emery O-ring
All WP10H

M10.1H with G-holder Art. no. 11045.1

EWP7/W, 100 ml

Art. no. 11201

S2

Art. no. 11906

20 x 1.5 silicone

Art. no. 11803

All WP10N
All WP10L

M10.1D with G-holder Art. no. 11041.1

All WP10-20%
All WP10MA-200

M10.1H with G-holder Art. no. 11045.1

All WP10MA-2000
All WP10MA-2%

M10.1D with G-holder Art. no. 11041.1

All WP10MA-5%
All WP10MA-10%
All WP10MA-20%

(Subject to technical changes!)

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2015

  • Ecer Certification:

    Verified Supplier

Suzhou Delfino Environmental Technology Co., Ltd. is a professional manufacturer of water analysis instruments and sensors, integrating development and production together. Our main products include online, portable water quality analysis instruments. Since its establishment, we have focused on the ... Suzhou Delfino Environmental Technology Co., Ltd. is a professional manufacturer of water analysis instruments and sensors, integrating development and production together. Our main products include online, portable water quality analysis instruments. Since its establishment, we have focused on the ...

+ Read More

Get in touch with us

  • Reach Us
  • Suzhou Delfino Environmental Technology Co., Ltd.
  • Room 301, Building 3, No. 25 Datong Road, High-tech Zone, Suzhou City, JIANGSU P.R CHINA
  • https://www.phorpanalyzer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement