China factories

China factory - Suzhou Delfino Environmental Technology Co., Ltd.

Suzhou Delfino Environmental Technology Co., Ltd.

  • China,Suzhou ,Jiangsu
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China 2 SPST Relays 220V AC Online pH ORP Meter For Industrial Sewage
China 2 SPST Relays 220V AC Online pH ORP Meter For Industrial Sewage

  1. China 2 SPST Relays 220V AC Online pH ORP Meter For Industrial Sewage
  2. China 2 SPST Relays 220V AC Online pH ORP Meter For Industrial Sewage
  3. China 2 SPST Relays 220V AC Online pH ORP Meter For Industrial Sewage

2 SPST Relays 220V AC Online pH ORP Meter For Industrial Sewage

  1. MOQ: Negotiable
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms D/A, L/C, D/P, T/T, Western Union, MoneyGram
Supply Ability 100 Unit/Week
Delivery Time 7-10 work days
Packaging Details Carton and PE foam for PH ORP Analyzer Meter
Product Name PH ORP controller
PH Range 0 ~ 14pH
ORP Range ± 2000mV
Temperature Range -10~150℃ /14~302℉
Resolution 0.01pH/1mV/0.1℃
Protection Grade IP66
Operating Temperature 0~60℃
Power Supply 18 ~ 36V DC
Shell Material Enhanced ABS
Power Consumption 3W
Mounting Method Panel installation
Weight 500g
Brand Name Daruifuno
Model Number APX1-C1
Certification CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms D/A, L/C, D/P, T/T, Western Union, MoneyGram Supply Ability 100 Unit/Week
Delivery Time 7-10 work days Packaging Details Carton and PE foam for PH ORP Analyzer Meter
Product Name PH ORP controller PH Range 0 ~ 14pH
ORP Range ± 2000mV Temperature Range -10~150℃ /14~302℉
Resolution 0.01pH/1mV/0.1℃ Protection Grade IP66
Operating Temperature 0~60℃ Power Supply 18 ~ 36V DC
Shell Material Enhanced ABS Power Consumption 3W
Mounting Method Panel installation Weight 500g
Brand Name Daruifuno Model Number APX1-C1
Certification CE Place of Origin China
High Light 220V AC Online ORP MeterpH Online ORP Meter2 SPST Relays Online ORP Meter

 

2 SPST Relays 220V AC Online pH ORP Meter for industrial sewage

 

The APX1-C1 from DELFINO is a real-time online monitoring controller for pH and ORP measurements. It can be connected to a variety of traditional pH or ORP composite sensors to meet the needs of a variety of applications.

 

PH ORP Controller Features:

  • 3.2 inch black and white LCD screen

  • High temperature resistance, aging resistance mask, key highlighting treatment, life up to 1 million times

  • IP66 protection grade, strong sealing type waterproof electrical interface

  • The base model is equipped with a current of 4 to 20 MA

  • Two SPST relays to set high and low alarms and control dosing

  • With temperature detection and compensation function

 

PH ORP Controller Parameters:

 

Product Name

PH ORP controller

Product Model APX1-C1
PH Range

0~14pH

ORP Range ± 2000mV
Temperature Range

-10~150℃ /14~302℉

Resolution

0.01pH / 1mV/ 0.1℃

Accuracy

PH:±0.02 pH /ORP:±2 mV

Stability

0.05% of the measurement range per 24 hours, no accumulation

Temp Compensation

Automatic or manual (NTC10K/PT1000)

Sensor Diagnosis

Screen image display

Analog Current Output

1 settable 0/4~20mA active current loop output, maximum load 1000Ω

Relay Control

2 settable SPST relays, maximum load 3A / 250VAC

Screen Display

128*64 3.2-inch large graphic dot matrix LCD

Operating Environment

0~60℃, RH< 95%

Storage Environment

-20~70℃, RH < 55%

Power Supply

AC: 100~240V 50/60Hz or DC:18~36V

Power Consumption 3 W

Shell Material

Enhanced ABS

Size

100×100×120 mm(hole size 92*92mm)

Weight 500g

Mounting Method

Panel installation

 

 

The PH/ORP controller supports various installation methods and provides necessary installation accessories. The PH/ORP controller (APX1-C1) can be installed in a cabinet or a wall mount. The built-in support frame can be used to install the controller in either of the two modes. The first type of cabinet installation, the table into the cabinet open, and then the back with a support frame fixed. The second kind of wall-hanging installation, according to the gap distance of the holes on the wall hanging metal bracket, punch two screws on the wall, put the table into the metal bracket and fix it with the support frame, the installation is complete.

 

PH ORP Controller Applications:

 

The PH/ORP controller is also widely applied in water treatment monitoring, including drinking water, surface water source water quality, groundwater, environmental sewage discharge monitoring, urban drainage network monitoring, etc. In the industrial process monitoring aspects of chemical, petroleum, paper, food and medicine, electroplating, PCB making, etc.

 

 

If you are interested in the product PH ORP controller APX1-C1, please contact us.

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2015

  • Ecer Certification:

    Verified Supplier

Suzhou Delfino Environmental Technology Co., Ltd. is a professional manufacturer of water analysis instruments and sensors, integrating development and production together. Our main products include online, portable water quality analysis instruments. Since its establishment, we have focused on the ... Suzhou Delfino Environmental Technology Co., Ltd. is a professional manufacturer of water analysis instruments and sensors, integrating development and production together. Our main products include online, portable water quality analysis instruments. Since its establishment, we have focused on the ...

+ Read More

Get in touch with us

  • Reach Us
  • Suzhou Delfino Environmental Technology Co., Ltd.
  • Room 301, Building 3, No. 25 Datong Road, High-tech Zone, Suzhou City, JIANGSU P.R CHINA
  • https://www.phorpanalyzer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement