China factories

China factory - Suzhou Delfino Environmental Technology Co., Ltd.

Suzhou Delfino Environmental Technology Co., Ltd.

  • China,Suzhou ,Jiangsu
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China 4 - 20MA Output Free Chlorine Sensor CL4.2 With Flow Cell For Drinking Water
China 4 - 20MA Output Free Chlorine Sensor CL4.2 With Flow Cell For Drinking Water

  1. China 4 - 20MA Output Free Chlorine Sensor CL4.2 With Flow Cell For Drinking Water
  2. China 4 - 20MA Output Free Chlorine Sensor CL4.2 With Flow Cell For Drinking Water
  3. China 4 - 20MA Output Free Chlorine Sensor CL4.2 With Flow Cell For Drinking Water
  4. China 4 - 20MA Output Free Chlorine Sensor CL4.2 With Flow Cell For Drinking Water
  5. China 4 - 20MA Output Free Chlorine Sensor CL4.2 With Flow Cell For Drinking Water
  6. China 4 - 20MA Output Free Chlorine Sensor CL4.2 With Flow Cell For Drinking Water

4 - 20MA Output Free Chlorine Sensor CL4.2 With Flow Cell For Drinking Water

  1. MOQ: Negotiable
  2. Price: Negotiable
  3. Get Latest Price
Product Name Free chlorine sensor
Product Model CL4.2
Measurand(s) Free chlorine
PH Range 6~8
Pressure Range 0 ~ 1bar
Temperature Range 0 ~ 45 ℃
Response Time T90 ca. 30 seconds
Flow Rate About 30 l/h, low flow-dependence
Brand Name Daruifuno
Model Number CL4.2
Certification CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Product Name Free chlorine sensor Product Model CL4.2
Measurand(s) Free chlorine PH Range 6~8
Pressure Range 0 ~ 1bar Temperature Range 0 ~ 45 ℃
Response Time T90 ca. 30 seconds Flow Rate About 30 l/h, low flow-dependence
Brand Name Daruifuno Model Number CL4.2
Certification CE Place of Origin China
High Light Free Chlorine Sensor 20MADrinking Water Free Chlorine SensorReal Time Monitoring Residual Chlorine Sensor

4-20MA Output Free Chlorine Sensor CL4.2 With Flow Cell For Drinking Water

 

Amperometric Membrane Method (Amperometric Membrane Method) residual chlorine sensor CL4.2 is a sensor technology commonly used to measure the concentration of residual chlorine in water. It is based on the principle of electrochemistry, by measuring the current to determine the content of residual chlorine in the water sample.

 

Advantage:
High sensitivity: The film-attached residual chlorine sensor has high sensitivity and can perform accurate measurement in the range of low residual chlorine concentration, which is very important for applications that require strict monitoring of water quality.

Real-time monitoring: This sensor can provide real-time residual chlorine concentration data, allowing users to quickly understand changes in water quality and take necessary measures to maintain water quality safety.

Quick response: The film-attached sensor has a fast response speed, and can quickly detect changes in residual chlorine, so that measures can be taken in time to protect water quality.

Stability: These sensors typically have good long-term stability and repeatability, providing accurate and reliable measurements over long periods of time.

Automation integration: The film-attached residual chlorine sensor can be equipped with RS485 and integrated with the automation system to realize automatic monitoring and alarm, thereby reducing the need for manual operation and intervention.

 

With its high sensitivity, real-time monitoring capability and stability, the film-attached residual chlorine sensor CL4.2 is mainly used in the design of drinking water environment.

 

Specifications

Indicator Free chlorine
pH Range 6~8pH
Pressure Range 0~1 bar, no pressure surges or fluctuations
Temperature Range 0~45℃
Temp Compensation Integrated automatic temperature compensation
Response Time T90 30 seconds
Flow Rate About 30 L/h, low flow-dependence
Shaft Length standard 175 mm, and up to 220 mm in length (mA-Version)
Connection 2-pole terminal or M12 male
Material PVC-U and semipermeable membrane
Scope of Supply sensor, membrane cap, electrolyte
Power Supply 12~30V DC
Signal Output 4~20mA
Application

Drinking water,fresh water, process water.

The water must not contain any surfactants

pH-value must be constant.

 

Item Number Model

Measuring range

(ppm)

Resolution

(ppm)

Output signal Power supply
3326225 CL4.2H-M0c 0.005-2.000 0.001 Modbus RTU

9-30V DC

20-56mA

3326226 CL4.2N-M0c 0.05-20.00 0.01
3326227 CL4.2L-M0c 0.5-200.0 0.1

 

3326240 CL4.2MA0.5 0.01-0.50 0.01 4-20 mA

12-30V DC

RL: 50-900 Ω

3326241 CL4.2MA2 0.01- 2.00 0.01
3326242 CL4.2MA5 0.01-5.00 0.01
3326243 CL4.2MA10 0.01-10.00 0.01
3326244 CL4.2MA20 0.01- 20.00 0.01
3326245 CL4.2MA-100 0.1-100 0.1
3326246 CL4.2MA-200 0.1-200 0.1
3326250 CL4.2MA0.5-M12 0.01-0.50 0.01 4-20mA

12-30V DC

RL: 50-900 Ω

3326251 CL4.2MA2-M12 0.01-2.00 0.01
3326252 CL4.2MA5-M12 0.01-5.00 0.01
3326253 CL4.2MA10-M12 0.01-10.00 0.01
3326254 CL4.2MA20-M12 0.01-20.00 0.01
3326255 CL4.2MA-100-M12 0.1-100 0.1
3326256 CL4.2MA-200-M12 0.1-200 0.1

 

Chlorine sensor with membrane-covered, amperometric 2-electrode system. For the measurement of free inorganic chlorine at constant pH.

Areas of application: Fresh water free of surfactants and with constant pH
Scope of supply: CL4.2: sensor, membrane cap, electrolyte
 

Product description:

1. Measurand(s) : NaClO (sodium hypochlorite), Ca(ClO)2 (calcium hypochlorite), Cl2 (chlorine gas), chlorine
generated by membrane-electrolysis
2. Calibration: at the controller, via analytical chlorine determination by DPD-1 method
3. Interferences : ClO2 is being registered with factor 9 of its measured value; O3 is registered; with membrane-less chlorine electrolysis interferences may occur
4. pH range: 6~8
5. Pressure range: 0~1 bar, no pressure surges or fluctuations
6. Temperature range: 0~ 45℃ (no ice crystals in measurement water)
7. Integrated automatic temperature compensation
8. Response time: T90 ca. 30 seconds
9. Flow rate: about 30 l/h, low flow-dependence
10. Shaft length: standard 175 mm, and up to 220 mm in length (mA-Version)
11. Connection: for mA-version 2-pole terminal, M12 male or Modbus RTU with M12 male
12. Material: PVC-U and semipermeable membrane

 

 
 
 
 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2015

  • Ecer Certification:

    Verified Supplier

Suzhou Delfino Environmental Technology Co., Ltd. is a professional manufacturer of water analysis instruments and sensors, integrating development and production together. Our main products include online, portable water quality analysis instruments. Since its establishment, we have focused on the ... Suzhou Delfino Environmental Technology Co., Ltd. is a professional manufacturer of water analysis instruments and sensors, integrating development and production together. Our main products include online, portable water quality analysis instruments. Since its establishment, we have focused on the ...

+ Read More

Get in touch with us

  • Reach Us
  • Suzhou Delfino Environmental Technology Co., Ltd.
  • Room 301, Building 3, No. 25 Datong Road, High-tech Zone, Suzhou City, JIANGSU P.R CHINA
  • https://www.phorpanalyzer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement