Payment Terms | T/T, L/C |
Supply Ability | 200 sets per year |
Delivery Time | Negotiable |
Packaging Details | Standard export packing |
Color | Customers' request |
Engine brand | Perkins |
Alternator brand | Farrand / Stamford / Leroy Somer |
Cylinder number | 6L |
Starting method | By batteries |
Cooling method | Water cooled |
Brand Name | SHX |
Model Number | SPF825 |
Certification | ISO, CE |
Place of Origin | China |
View Detail Information
Explore similar products
AVR 1480kw Perkins Diesel Generator Set 1850kva 3 Phase Genset
ISO CE Perkins 350 Kva Generator 280kw Soundless Backup Generator For Home
250 Kva 200 Kw Perkins Diesel Generator Set Hospital Remote Start Diesel
SHX 230V 300kva Perkins Generator 240kw 3 Phase Silent Diesel Genset
Product Specification
Payment Terms | T/T, L/C | Supply Ability | 200 sets per year |
Delivery Time | Negotiable | Packaging Details | Standard export packing |
Color | Customers' request | Engine brand | Perkins |
Alternator brand | Farrand / Stamford / Leroy Somer | Cylinder number | 6L |
Starting method | By batteries | Cooling method | Water cooled |
Brand Name | SHX | Model Number | SPF825 |
Certification | ISO, CE | Place of Origin | China |
High Light | VDE0875N Perkins Diesel Generator Set ,Perkins 750kva Electric Power Unit ,ISO8528 600 kw perkins generator |
SHX 600kw Perkins Diesel Generator Set 750kva Generator Power Unit Electric Generator
Manufacturing Standards:
ISO8528; ISO1105; ISO3046; GB/T2820; GB755; BS5000; NEMAMG-22; YD/T502
Electrical Parameters
Wave distortion: <10%
Voltage fluctuation: <0.5%
Voltage / frequency fluctuation: <=0.5%
AVR self-regulated, voltage regulation rate: <=+- 1%
Radio interference restraining accords with stipulation of VDE0875-N and ISO8528
Specification of 600kw Perkins diesel generator set
Genset model | SPF825 |
Genset rated power | 600KW/750KVA |
Rated voltage | 400/230V (adjustable) |
Rated current | 1080 Amps |
Frequency | 50 Hz |
Power factor | 0.8 Lagging |
Connecting type | 3 phase 4 wire |
Cooling system | Closed cycle water-cooled with fan, water tank |
Overall dimension (L×W×H) mm | 4500×1900×2200 |
Gross weight (kg) | 6000 |
Diesel Engine | |
Brand | Perkins |
Model | 4006-23TAG2A |
Engine type | 6 cylinders in line,4 stroke, air-to-air after-cooled |
Aspiration | Turbocharged |
Rotating speed | 1500 RPM |
Engine cooling system | Water-cooled |
Speed governing system | Electronic speed governor |
Starting method | By 24V batteries |
Engine filter system | Dry type air filter ,fuel filter, oil filter, water filter |
Displacement(L) | 23 |
Bore×Stroke(mm) | 160×190 |
Compression ratio | 13.6: 1 |
100% Load fuel consumption (g/kw.h) | ≤209 |
Lube capacity(L) | 113.4 |
Alternator | |
Brand | Farrand |
Model | FLD634B |
Excite type | Brushless self-excited AVR regulation |
Connecting type | 3 phase 4 pole |
Steady frequency change | 0.50% |
No load voltage | ≥95%-105% |
Steady voltage | ≤±1% |
Insulation class | Class H |
Protection grade | IP23 |
The components of the genset | |
(1) Diesel engine; (2) Alternator; (3) Water tank & radiator assembly; (4) Control panel; (5) Base frame. |
Control Function
Key start / auto start
Monitoring meters: Current; Frequency; Wire Voltage; Genset KVA; Genset KW; Output
Capacity; Output KW.H; Power Factor.
Warning/Shutdown: Alternator Under/Over Volts, Frequency; Under/Over Speed; Low Oil Pressure; High Engine Temp; High/Low Battery Volts; Over Current; Earth Fault Shutdown.
SCOPE OF SUPPLY
1. DIESEL ENGINE
1.1 Engine which includes wet type cylinder, direct injection combustion chamber, exhaust turbocharger, water cooling, electronic governor, etc.
1.2 Fuel system, which includes, fuel pump, strainers or filters, etc.
1.3 Air intake and exhaust system, which includes air filter, exhaust silencer, bellow, all intake and exhaust piping, cablings, instruments, valves and settings, etc.
1.4 Cooling system, which includes radiator with water level alarm and indicator, thermostatic switch, thermostatic heater, engine shaft mounted fan, all interconnecting piping, cablings, instruments, valves and settings, etc.
1.5 Lubricating system includes pumps, oil sumps, oil strainers and filters, all interconnecting piping, instruments, valves and settings, etc.
1.6 Starting system, which includes 2 sets of batteries, a set of AC charger, and interconnecting piping, cablings, instrument, valves and settings, etc.
2. AC SYNCHRONOUS GENERATOR
2.1 Generator, which includes exciter, rectifier, AVR, shaft mounted fan if required.
2.2 All interconnecting piping, cablings, instruments, valves and settings, etc.
3. COUPLINGS AND GUARD
3.1 Coupling
3.2 Coupling Guard
4. CONTROL PANEL
4.1 Local automatic control panel
5. BASEPLATE
5.1 Common base plate
6. DOCUMENTS
6.1 Generator Set Installation Manual
6.2 Generator Set Operation and Maintenance Manual
6.3 Generator Set Control Panel Manual
6.4 Engine Manual and Quality File
6.5 Alternator Manual and Quality File
6.6 Factory Acceptant Test Report
6.7 Relative Drawings and Diagrams.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2000
Total Annual:
1500-2000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
We make Diesel Generator Sets /Biogas Generator Sets covering 20KW to 2400KW (25KVA to 3000KVA), and offer fully power solutions for agricultural and industrial purpose. We are the appointed OEM partner of Cummins, Perkins, Volvo and Daewoo.Excellent engines equipped with world-known alternators suc... We make Diesel Generator Sets /Biogas Generator Sets covering 20KW to 2400KW (25KVA to 3000KVA), and offer fully power solutions for agricultural and industrial purpose. We are the appointed OEM partner of Cummins, Perkins, Volvo and Daewoo.Excellent engines equipped with world-known alternators suc...