Payment Terms | T/T, Western Union,PayPal |
Supply Ability | In stock |
Delivery Time | 3-5 working days |
Packaging Details | Standard |
Product name | FX-7202 ECG Machine ECG AMP Board |
Model | PCB-6867C |
Brand | FUKUDA |
Warranty | 90days |
Features | Professional, reliable,Economic |
Power supply source | Electric |
Mode of transport | Express delivery |
Use for | FX-7202 ECG Machine |
MOQ | 1 pcs |
Payment method | T/T ,Paypal ,Western Union |
Condition | Used in Good Working |
Packing | Carton |
Brand Name | FUKUDA |
Model Number | PCB-6867C |
View Detail Information
Explore similar products
Patient Monitor Accessories Goldway UT4000 Monitor Blood Pressure Plate Great
Mindray PM7000 Patient Monitor Accessories Keyboard Silicone 7000-20-24395
Well-chosen Patient Monitor Mainboard Goldway G30 40 60 70 80 UT4000B UT6000
Patient Monitor Repair Parts GE Dash4000 Patient Monitor Flat Cable in ready
Product Specification
Payment Terms | T/T, Western Union,PayPal | Supply Ability | In stock |
Delivery Time | 3-5 working days | Packaging Details | Standard |
Product name | FX-7202 ECG Machine ECG AMP Board | Model | PCB-6867C |
Brand | FUKUDA | Warranty | 90days |
Features | Professional, reliable,Economic | Power supply source | Electric |
Mode of transport | Express delivery | Use for | FX-7202 ECG Machine |
MOQ | 1 pcs | Payment method | T/T ,Paypal ,Western Union |
Condition | Used in Good Working | Packing | Carton |
Brand Name | FUKUDA | Model Number | PCB-6867C |
High Light | FUKUDA CardiMAX FX-7202 E ECG Machine Part ,ECG Machine ECG AMP Board ,ECG AMP Board PCB-6867C |
FUKUDA CardiMAX FX-7202 ECG Machine ECG AMP Board PCB-6867C Used in Good Working ECG Machine Part
►Brief Introduction
Cardimax FX-7202 complies with the safety standards IEC60601-2-25 (1999) and IEC60601-1-2 (2001). However, if there is strong electromagnetic waves in the vicinity that exceed the regulations, the device may malfunction. In such a case, please take the necessary measures.
Effects of radiated electromagnetic waves:
The use of mobile phones may affect the operation of the FX-7202. Please ask the personnel in charge of the facility housing medical electronic equipment to turn off mobile phones and small radios.
Effects of sudden conducted electromagnetic waves:
High-frequency noise from other equipment may enter the FX-7202 through the AC outlet. Identify the source of the noise and, if possible, stop using the device.
If it is not possible to turn off the device, take measures to block this noise path using noise suppression equipment, etc.
Effects of static electricity:
Electrostatic discharge may affect the operation of the FX-7202, especially in a dry environment (room) in winter. Before using the FX-7202, humidify the room or discharge static electricity from the patient and the person recording the ECG.
► Specifications
Product Model | PCB-6867C |
Brand name | FUKUDA CardiMAX |
Product name | ECG Machine ECG AMP Board |
MOQ | 1 Piece |
Warranty | 90 Days |
Payment Method | T/T ,Paypal ,Western Union |
Use for | FX-7202 ECG Machine |
Product Edge | Original,Advanced equipment |
Delivery | 3-5 Working Days |
Power Supply Source | Electric |
Payment Terms | Full Before Shippment |
Delivery Method | DHL ,Fedex ,UPS |
Product Characteristic | Functional,Durable in use |
Method of Transport | Expressage |
Condition | Used in Good Working |
Stock Situation | Stock available |
Performance | Good |
Packing | Carton |
►ECG signal input circuit
Input protection and filter circuit: Receives ECG signals at the ECG leads, eliminates high-frequency interference, and prevents damage to the circuit caused by defibrillation high voltage and electrostatic discharge.
Right leg drive circuit: Picks up 50/60Hz common-mode signals at the leads and feeds them back to the patient's body to suppress common-mode interference at the leads and better detect the ECG signal.
Lead missing detection circuit: Detects ECG lead falling off and sends related information to the CPU.
A/D
Convert analog signals output from each parameter circuit into digital signals, and send them into CPU part to receive further processing.
Power & Signal Isolate Circuit
Realize isolation from external circuit in order to ensure human safety;
Provide power supplies for circuits;
Realize isolating communication between CPU System and main board.
CPU System
Realize logic control over all parameter parts and A/D part.
Process data of each parameter;
Communicate with main board.
If you want to explore more details about FUKUDA CardiMAX FX-7202 ECG Machine ECG AMP Board PCB-6867C Used in Good Working ECG Machine Part, please let us know. Looking forward to receiving your early inquiry.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller
Year Established:
2015
Employee Number:
20~50
Ecer Certification:
Verified Supplier
China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...
Get in touch with us
Leave a Message, we will call you back quickly!