Payment Terms | T/T(wire transfer), Western Union, Paypal |
Delivery Time | 3-5 working days |
Packaging Details | Carton |
Model Numbe | 25-35cm DLG-011-01 |
certification | CE |
Weight | 280g |
Scope of use | adult |
length | 25-35cm |
Transportation method | international express |
Package | Foam plus carton |
Color | blue |
Condition | NEW or Used |
Brand Name | GE Adult NIBP Cuff Double Hose |
Model Number | Adult NIBP Cuff Double Hose 25-35cm DLG-011-01 |
Certification | CE/CB/ROSH |
View Detail Information
Explore similar products
Mindray ECG Leadwires EL6802A 12-Lead Limb Cable IEC Clip PN0010-30-42903 For
TS-W-D Patient Monitor Accessories GE Ohmeda TruSignal 9 Pin Spo2 Wrap Sensor
CBL 3 Lead ECG Safety Patient Trunk Cable IEC PN M1510A Ref 989803103871 for
M1024254 GE Pediatric Reusable Temperature Probes 400 Series Skin Probe 3m 10ft
Product Specification
Payment Terms | T/T(wire transfer), Western Union, Paypal | Delivery Time | 3-5 working days |
Packaging Details | Carton | Model Numbe | 25-35cm DLG-011-01 |
certification | CE | Weight | 280g |
Scope of use | adult | length | 25-35cm |
Transportation method | international express | Package | Foam plus carton |
Color | blue | Condition | NEW or Used |
Brand Name | GE Adult NIBP Cuff Double Hose | Model Number | Adult NIBP Cuff Double Hose 25-35cm DLG-011-01 |
Certification | CE/CB/ROSH | ||
High Light | Double Hose Adult NIBP Cuff ,35cm Adult NIBP Cuff ,monitors measurement Adult NIBP Cuff |
This product is an adult NIBP cuff, latex-free and made of pure cotton.
What should I do if the NIBP is underinflated during blood pressure monitoring?
When measuring blood pressure, "the cuff is too loose" or the cuff is leaking, and the inflation pressure cannot be inflated (lower than 150mmHg), making it impossible to measure.
Approach:
(1) There may be real air leaks, such as in the cuff, airway tube and various joints, which can be determined through "air leakage detection".
(2) The patient mode selection is incorrect. If an adult cuff is used but the patient type of the monitor is a newborn, this alarm may occur.
Troubleshooting method: Replace the blood pressure cuff with good quality or choose a suitable type.
What should I do if the NIBP measurement value during blood pressure monitoring is inaccurate?
The measured blood pressure value deviates too much.
Treatment method: Check whether the blood pressure cuff is leaking, and whether the pipe interface connected to the blood pressure is leaking. Or is it caused by the difference in subjective judgment between the auscultation method and the auscultation method?
Troubleshooting method: Use the NIBP calibration function. This is the only standard available to verify that the NIBP module calibration values are correct at the user's site. The standard deviation of the pressure tested by NIBP before leaving the factory is within 8mmHg. If it exceeds, the blood pressure module needs to be replaced.
1. Adopt one-piece bagless design, smooth and comfortable
2. Adopt humanized rounded corner design, beautiful appearance and comfortable to use.
3. With different types of connectors, the cuff can be applied to various monitor series
4. For adults to meet patient needs
5. Double tube design
6. Latex-free and biocompatibility tested
7. Comply with ANSI/AAMI SP10-2002, EN60601-1:1990
Routinely measure upper arm blood pressure. Routine measurement of wrist blood pressure and finger blood pressure is not recommended.
① It is recommended to measure the blood pressure of the left and right upper arms (brachial artery) for the first time, and use the side with higher blood pressure as the upper limb for blood pressure measurement.
②When the difference in blood pressure (systolic blood pressure) between the left and right upper arms is >20 mmHg, it is recommended to measure blood pressure in the limbs.
③The elderly and patients with diabetes or certain diseases are prone to orthostatic hypotension, so measure blood pressure in multiple positions. Blood pressure can be measured in the supine or standing position when necessary. The standing blood pressure measurement should be performed 3 minutes after the patient changes from lying to standing.
Model | Adult NIBP Cuff Double Hose |
certification | CE |
LATEX | NO |
Material | cotton |
Size | 25-35cm |
Warranty | 90 days |
Condition | Good |
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller
Year Established:
2015
Employee Number:
20~50
Ecer Certification:
Verified Supplier
China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te... China World Technology Medical Equipment Service Group is a company engaged in medical equipments/repair parts and accessories products trading company. The company was established in September 2005, has many famous enterprises at home and abroad (such as America USCO company) to establish a long-te...
Get in touch with us
Leave a Message, we will call you back quickly!