Submit Requirement
China Traffic Inductive Loop Vehicle Detector Double Channel Ground Sensors AC220
China Traffic Inductive Loop Vehicle Detector Double Channel Ground Sensors AC220

  1. China Traffic Inductive Loop Vehicle Detector Double Channel Ground Sensors AC220

Traffic Inductive Loop Vehicle Detector Double Channel Ground Sensors AC220

  1. MOQ: 1 set
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms L/C, T/T, Western Union
Supply Ability 800 set/month
Delivery Time 3-10 working days after received your payment
Packaging Details Export Wooden Case
Dimensions 78x40x108 Mm (WxHxL)
Color Red/Black
Power Suppply 240VAC/ 110VAC/12VDC/24VDC
Working frequency 20-300uh
Reaction Time 100ms
Net Weight 300g
Brand Name MAX
Model Number PD132
Certification CE, ISO, SGS
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T, Western Union Supply Ability 800 set/month
Delivery Time 3-10 working days after received your payment Packaging Details Export Wooden Case
Dimensions 78x40x108 Mm (WxHxL) Color Red/Black
Power Suppply 240VAC/ 110VAC/12VDC/24VDC Working frequency 20-300uh
Reaction Time 100ms Net Weight 300g
Brand Name MAX Model Number PD132
Certification CE, ISO, SGS Place of Origin China
High Light car loop detectorautomatic garage door opener

 Traffic Inductive Loop Vehicle Detector Double Channel Ground Sensors AC220 AC110V DC12 DC24V

 
Specification :
Supply voltage: 230V AC , 115V AC, 24V DC/AC, 12V DC/AC
(See the label on the detector)
Voltage tolerance AC: +10% / -15%
Voltage tolerance DC: ±15%
Power Consumption: 4.5VA
Output relays: 240V/5A
Operating temperature: -20°c to +65°c
Storage temperature: -40°c to +85°c
Frequency range: 20 kHz to 170 kHz
Reaction time: 100ms
Signal holding time: Unlimited
Sensitivity:Adjustable in 3 increments
Loop inductance: Total loop plus connection wiring: 50μH to 1000μH.
Ideal is 100μH to 300μH
Loop connection wiring: Maximum length 20 meters, twistedat least 20 times per meter
Install Detector Wiring Diagram
Theloop detectors must only be placed in dry rooms or control cabinets that are protected against all types of moisture and wetness. A distance of at least (10-20) mm from other devices must be maintained on each side. The ambient temperature must not exceed 55°c. The installation of the induction loop is described in other operating instructions.
Operation and Indication
Whenthe power is applied, the red Power LED will glow and the detector is tuning,the green Check LED blink about 3 seconds. The green LED will also glow whenever a vehicle is detected passing over the inductive loop. If a loop fault
exists the green LED will come on and flash indicating a fault.
Loopno connected: Loop too small:
Looptoo large:
 
Frequency
Thefrequency can be set by the two DIP switch on the circuit board. Disconnect power and then take down the detector from the socket, remove the shell. DIP6 (LA) is used for setting the frequency. ON: working in low frequency. OFF:working in high frequency The detector will be calibrated automatically when connecting the power after adjusting the frequency. Notice: High frequency has been set. The installation distance is too close between the two loop
detectors, the different frequency can be setting by the user.Sensitivity The response sensitivity can be set using the threestage switch on the front. The setting L corresponds to the lowest sensitivity. M is the medium sensitivity and H is the highest sensitivity. After the sensitivity has been set, a reset and a calibration automatically takes place.
Attention If thedetector isn’t working normally, you must check the loop and wiring at first, and then alter the frequency or the sensitivity.
 
Output Relay
Whenvehicle press loop, the relay's output mode set by the main control panel switch. TLD-410 has two loops, corresponding to two output relays. loop1 (7-8 pin) corresponds to the relay 1 (5, 6, 10 pin) output for the existence of a fixed output signal, the loop 2 (7,9 pin) corresponds to the relay 2 (3,4,11 pin) and pull the output signal from the DIP code switch DIP1, DIP2, DIP3 (SW0,SW1, SW2) decision.ListenRead phonetically.Vehiclepresence check model output setting Vehicle direction (count) check mode output signal and setting:
 
Reset
Thedetector automatically reset and tune to the inductive loop when the power is applied, whether on initial installation or after any break in power supply.Should it be necessary to retune the detector, as may be required after
changing any of the switches or after moving the detector from one installation to another.
  
 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Trading Company,Seller

  • Year Established:

    2010

  • Total Annual:

    80000-100000

  • Employee Number:

    10~50

  • Ecer Certification:

    Active Member

WHO we are Founded in 2002, Shenzhen Maixiang Technology Co. Ltd is a manufacture of barrier gate, tripod turnstile, UHF Reader, pedestrian barrier series and parking industry professionals. who are devoted to bringing innovating new ideas to the world of electronic barrier gates and parking sys... WHO we are Founded in 2002, Shenzhen Maixiang Technology Co. Ltd is a manufacture of barrier gate, tripod turnstile, UHF Reader, pedestrian barrier series and parking industry professionals. who are devoted to bringing innovating new ideas to the world of electronic barrier gates and parking sys...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Maixiang Technology Co.,Ltd
  • Longgang Shenzhen City, China
  • https://www.parking-barriergate.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement